Comparison of keratometry versions in patients with corneal astigmatism
Purpose: to compare the corneal power at main meridians, the magnitude and the axis of corneal astigmatism and the reproducibility of measurements taken three times with different types of biometers. Material and methods. 22 subjects (24 eyes) with regular corneal astigmatism 1.89–8.02 D were given...
Saved in:
Published in | Rossiĭskiĭ oftalʹmologicheskiĭ zhurnal Vol. 15; no. 2 (Прил); pp. 84 - 92 |
---|---|
Main Authors | , , |
Format | Journal Article |
Language | English Russian |
Published |
Real Time Ltd
16.06.2022
|
Subjects | |
Online Access | Get full text |
ISSN | 2072-0076 2587-5760 2587-5760 |
DOI | 10.21516/2072-0076-2022-15-2-supplement-84-92 |
Cover
Abstract | Purpose: to compare the corneal power at main meridians, the magnitude and the axis of corneal astigmatism and the reproducibility of measurements taken three times with different types of biometers.
Material and methods. 22 subjects (24 eyes) with regular corneal astigmatism 1.89–8.02 D were given three biometry tests using IOL Master 500, Lenstar LS 900, IOL Master 700, Pentacam and Galilei G6.
Results. The data were divided into groups depending on the principle of mathematical modeling of the corneal surface: group I involved the material processed by IOL Master 500, Lenstar LS 900, IOL Master 700; group II contained maps of the anterior corneal surface; and group III, those of the posterior surface. In group I, Lenstar showed the highest values of keratometry. In group II, the values of K1 , Kave in the 6 mm area were lower than in the pupil diameter area and than any values of K in the 4 mm area; the lowest values of K in this area were obtained on the Pentacam SimK. In group III, in the pupil diameter area (4.0–4.5 mm), all K values obtained with diverse equipment were different whilst in the 6 mm area the values differed only in the flat meridian. Astigmatism within groups I, III showed no difference while in group II the SimK data were different. The astigmatism axes obtained on IOLMaster 500 differed from the respective data provided by other devices. The devices of group I, 6 mm area, were the most stable.
Conclusions. The highest values of keratometry are obtained when only the anterior surface of the cornea is taken into account, the lowest values are characteristic of the posterior surface. The stability of the parameter registered grew with the increase of the measured zone diameters. The biometers of group 1 showed the highest values of astigmatism with the maximum repeatability of the measurements |
---|---|
AbstractList | Purpose: to compare the corneal power at main meridians, the magnitude and the axis of corneal astigmatism and the reproducibility of measurements taken three times with different types of biometers.
Material and methods. 22 subjects (24 eyes) with regular corneal astigmatism 1.89–8.02 D were given three biometry tests using IOL Master 500, Lenstar LS 900, IOL Master 700, Pentacam and Galilei G6.
Results. The data were divided into groups depending on the principle of mathematical modeling of the corneal surface: group I involved the material processed by IOL Master 500, Lenstar LS 900, IOL Master 700; group II contained maps of the anterior corneal surface; and group III, those of the posterior surface. In group I, Lenstar showed the highest values of keratometry. In group II, the values of K1 , Kave in the 6 mm area were lower than in the pupil diameter area and than any values of K in the 4 mm area; the lowest values of K in this area were obtained on the Pentacam SimK. In group III, in the pupil diameter area (4.0–4.5 mm), all K values obtained with diverse equipment were different whilst in the 6 mm area the values differed only in the flat meridian. Astigmatism within groups I, III showed no difference while in group II the SimK data were different. The astigmatism axes obtained on IOLMaster 500 differed from the respective data provided by other devices. The devices of group I, 6 mm area, were the most stable.
Conclusions. The highest values of keratometry are obtained when only the anterior surface of the cornea is taken into account, the lowest values are characteristic of the posterior surface. The stability of the parameter registered grew with the increase of the measured zone diameters. The biometers of group 1 showed the highest values of astigmatism with the maximum repeatability of the measurements Purpose: to compare the corneal power at main meridians, the magnitude and the axis of corneal astigmatism and the reproducibility of measurements taken three times with different types of biometers.Material and methods. 22 subjects (24 eyes) with regular corneal astigmatism 1.89–8.02 D were given three biometry tests using IOL Master 500, Lenstar LS 900, IOL Master 700, Pentacam and Galilei G6.Results. The data were divided into groups depending on the principle of mathematical modeling of the corneal surface: group I involved the material processed by IOL Master 500, Lenstar LS 900, IOL Master 700; group II contained maps of the anterior corneal surface; and group III, those of the posterior surface. In group I, Lenstar showed the highest values of keratometry. In group II, the values of K1 , Kave in the 6 mm area were lower than in the pupil diameter area and than any values of K in the 4 mm area; the lowest values of K in this area were obtained on the Pentacam SimK. In group III, in the pupil diameter area (4.0–4.5 mm), all K values obtained with diverse equipment were different whilst in the 6 mm area the values differed only in the flat meridian. Astigmatism within groups I, III showed no difference while in group II the SimK data were different. The astigmatism axes obtained on IOLMaster 500 differed from the respective data provided by other devices. The devices of group I, 6 mm area, were the most stable.Conclusions. The highest values of keratometry are obtained when only the anterior surface of the cornea is taken into account, the lowest values are characteristic of the posterior surface. The stability of the parameter registered grew with the increase of the measured zone diameters. The biometers of group 1 showed the highest values of astigmatism with the maximum repeatability of the measurements |
Author | Kozhevnikov, E. Yu Danilenko, E. V. Kulikov, A. N. |
Author_xml | – sequence: 1 givenname: A. N. surname: Kulikov fullname: Kulikov, A. N. organization: S.M. Kirov Military Medical Academy – sequence: 2 givenname: E. V. surname: Danilenko fullname: Danilenko, E. V. organization: S.M. Kirov Military Medical Academy – sequence: 3 givenname: E. Yu surname: Kozhevnikov fullname: Kozhevnikov, E. Yu organization: S.M. Kirov Military Medical Academy |
BookMark | eNqd0MFO3DAQgGELgQSlvENewO14EsfJEa2AIpB6oWdr7DhgmtiRbYr27ZtlaZG4wWlGY_k7_F_YYYjBMcYFfEMhRfsdQSEHUC1HQORCcuT5aVkmN7tQeNfwHg_YCcpOcalaOFz3f1-O2VnOjwCAPXRKdSfsahPnhZLPMVRxrH67RCXOrqRt9cel7GPIlQ_VQsWveq6efXmobEzB0VRRLv5-Xp_y_JUdjTRld_Y6T9mvy4u7zQ9--_PqenN-yy3KHvkw0li73hoDyhqqxeBs3aAZVS-sHYRzyjish1FKAZKcqdFQjyAaappBtPUpu967Q6RHvSQ_U9rqSF6_HGK615SKt5PTqrNiaBW0QKYBK8l0tnbteu1F3dmddbm3nsJC22eapv-gAP1SW-_S6V06vauthdSo32rrrtE9rtDFHrIp5pzc-Gnn5p1jfVnzxlAS-emD2l8bfqqT |
CitedBy_id | crossref_primary_10_29413_ABS_2024_9_5_21 crossref_primary_10_17816_OV626398 |
Cites_doi | 10.1186/s12886-018-0692-7 10.1016/S0140-6736(18)33209-4 10.1007/s10792-018-1006-z 10.1016/j.jcrs.2014.08.036 10.3341/kjo.2017.0091 10.4103/0301-4738.182939 |
ContentType | Journal Article |
DBID | AAYXX CITATION ADTOC UNPAY DOA |
DOI | 10.21516/2072-0076-2022-15-2-supplement-84-92 |
DatabaseName | CrossRef Unpaywall for CDI: Periodical Content Unpaywall DOAJ Directory of Open Access Journals |
DatabaseTitle | CrossRef |
DatabaseTitleList | CrossRef |
Database_xml | – sequence: 1 dbid: DOA name: DOAJ Directory of Open Access Journals url: https://www.doaj.org/ sourceTypes: Open Website – sequence: 2 dbid: UNPAY name: Unpaywall url: https://proxy.k.utb.cz/login?url=https://unpaywall.org/ sourceTypes: Open Access Repository |
DeliveryMethod | fulltext_linktorsrc |
EISSN | 2587-5760 |
EndPage | 92 |
ExternalDocumentID | oai_doaj_org_article_78c1d67060ab40c5ab8c3e68c19138c6 10.21516/2072-0076-2022-15-2-supplement-84-92 10_21516_2072_0076_2022_15_2_supplement_84_92 |
GroupedDBID | 642 AAYXX ALMA_UNASSIGNED_HOLDINGS CITATION GROUPED_DOAJ ADTOC UNPAY |
ID | FETCH-LOGICAL-c2592-dfaf3e9cbb07cba31dec342bf791ccd1ee7be23df55105aeb32ba92014a44d163 |
IEDL.DBID | DOA |
ISSN | 2072-0076 2587-5760 |
IngestDate | Wed Aug 27 01:28:55 EDT 2025 Tue Aug 19 16:15:18 EDT 2025 Thu Apr 24 22:56:04 EDT 2025 Tue Jul 01 01:45:55 EDT 2025 |
IsDoiOpenAccess | true |
IsOpenAccess | true |
IsPeerReviewed | true |
IsScholarly | true |
Issue | 2 (Прил) |
Language | English Russian |
License | cc-by |
LinkModel | DirectLink |
MergedId | FETCHMERGED-LOGICAL-c2592-dfaf3e9cbb07cba31dec342bf791ccd1ee7be23df55105aeb32ba92014a44d163 |
OpenAccessLink | https://doaj.org/article/78c1d67060ab40c5ab8c3e68c19138c6 |
PageCount | 9 |
ParticipantIDs | doaj_primary_oai_doaj_org_article_78c1d67060ab40c5ab8c3e68c19138c6 unpaywall_primary_10_21516_2072_0076_2022_15_2_supplement_84_92 crossref_primary_10_21516_2072_0076_2022_15_2_supplement_84_92 crossref_citationtrail_10_21516_2072_0076_2022_15_2_supplement_84_92 |
ProviderPackageCode | CITATION AAYXX |
PublicationCentury | 2000 |
PublicationDate | 2022-06-16 |
PublicationDateYYYYMMDD | 2022-06-16 |
PublicationDate_xml | – month: 06 year: 2022 text: 2022-06-16 day: 16 |
PublicationDecade | 2020 |
PublicationTitle | Rossiĭskiĭ oftalʹmologicheskiĭ zhurnal |
PublicationYear | 2022 |
Publisher | Real Time Ltd |
Publisher_xml | – name: Real Time Ltd |
References | ref13 ref12 ref11 ref10 ref2 ref1 ref8 ref7 ref9 ref4 ref3 ref6 ref5 |
References_xml | – ident: ref13 – ident: ref1 – ident: ref4 – ident: ref7 doi: 10.1186/s12886-018-0692-7 – ident: ref3 – ident: ref6 – ident: ref2 doi: 10.1016/S0140-6736(18)33209-4 – ident: ref9 – ident: ref10 doi: 10.1007/s10792-018-1006-z – ident: ref8 doi: 10.1016/j.jcrs.2014.08.036 – ident: ref11 doi: 10.3341/kjo.2017.0091 – ident: ref5 doi: 10.4103/0301-4738.182939 – ident: ref12 |
SSID | ssj0002908778 |
Score | 2.1890392 |
Snippet | Purpose: to compare the corneal power at main meridians, the magnitude and the axis of corneal astigmatism and the reproducibility of measurements taken three... |
SourceID | doaj unpaywall crossref |
SourceType | Open Website Open Access Repository Enrichment Source Index Database |
StartPage | 84 |
SubjectTerms | corneal astigmatism galilei g6 iol master 500 iol master 700 keratometry keratotopography lenstar ls 900 pentacam |
SummonAdditionalLinks | – databaseName: Unpaywall dbid: UNPAY link: http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwpV1Jb9QwFLbKVGI5sAgQwyYfuHqSeI0voFIoFRIVSIxUTpbXqnSaVJkZUPn1-GUyYbkVbpHlvDj-7Ph7z873EHohpdCprhmhSUrCY6qI00wTp6SqfMWisxDv-HAkD-f8_bE43kHl9l-Yrv06Oz1xs25dQGcWQ_8VAaTjWxsKLUXBpbyGdiVsKU3Q7vzo494XyCFXKkpgZwmuRZ47mUqX1xGB0855XZPFWCEPjeyCVYJQsoTcmX0gjtScaPrH8tSr-N9CN9bNhb38bheL35aegzvo07bRmxMnZ7P1ys38j7_0HK_yVnfR7YGH4r1NlXtoJzb30bv9MSshbhM-A8Hl9jyuukv8bRNXW-LTBg9arEsMQVyc3dcms01sQa4D-O_y_AGaH7z9vH9IhkwLxGf3h5KQbGJRe-dK5Z1lVYieceqS0pX3oYpRuUhZSAL4mM0OOHVWZ-7ALechU7qHaNK0TXyEsMgfDUujCFFErlKuLJXzToekWMjPmaI32w42fpAhh2wYC5PdkR4nAzgZwMkATqYShppfOJmaG02n6OVo5mKjy3FVA68B3fFmkNnuC9ruxAz4GFX7KkgQGLKOl15YV3sWZS7VFau9nKJX49j4t2Y8_m8LT9DNfjhDPiX5FE1W3To-y0Rp5Z4Pc-MnPV8Pow priority: 102 providerName: Unpaywall |
Title | Comparison of keratometry versions in patients with corneal astigmatism |
URI | https://roj.igb.ru/jour/article/download/965/466 https://doaj.org/article/78c1d67060ab40c5ab8c3e68c19138c6 |
UnpaywallVersion | publishedVersion |
Volume | 15 |
hasFullText | 1 |
inHoldings | 1 |
isFullTextHit | |
isPrint | |
journalDatabaseRights | – providerCode: PRVAON databaseName: DOAJ Directory of Open Access Journals customDbUrl: eissn: 2587-5760 dateEnd: 99991231 omitProxy: true ssIdentifier: ssj0002908778 issn: 2072-0076 databaseCode: DOA dateStart: 20160101 isFulltext: true titleUrlDefault: https://www.doaj.org/ providerName: Directory of Open Access Journals |
link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwrV1LaxRBEG4kgo-DKCpuNKEPXptsv6cvkZgYg2Dw4EI8Nf0EcTMb9mHIv0_VzGRcT6J4LWZ6iq9rph7TfB8hb43RrjaNZKIaw1SpnEUnHYvWWJ64LDHgvOPzuTmbqU8X-mJL6gvPhPX0wD1wB7ZJPBvkeAlRTZMOsUmyGLA6LpvUkW1DGttqpvAbLBwS3XVydFMrGP5vekAYnnuGDGcORiMECTRjXDPBVqii2Y3kWKOYE78lqo7P_zF5uGmvws11mM-3ktDpU_JkqB7pUe_1M3JvuXlOPh6PWoJ0UekPpEleXJb18ob-7KdhK_q9pQOD6ori6JVC09lCjUgDkmxg1bq6fEFmpx--Hp-xQR-BJWhaBMs1VFlcinFqUwyS55KkErFax1PKvBQbi5C5aqyiArTNIgYHGV8FpTIUYi_JTrtoyytCNbzqQRSdiy7KVrjY2Jiiy9XKDM-ZkJM7MHwayMNRw2LuoYnoMPWIqUdMPWLqufbC_8LUN8o7MSGH4zJXPZvG3y7wHndivBnJsTsDhIwfQsb_KWQm5N24j__mxu7_cOM1edRFHwohmTdkZ73clD2ocNZxvwvmfXJ_dv7l6NstEs724g |
linkProvider | Directory of Open Access Journals |
linkToUnpaywall | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwpV1Jb9QwFLbKVGI5sAgQwyYfuHqSeI0voFIoFRIVSIxUTpbXqnSaVJkZUPn1-GUyYbkVbpHlvDj-7Ph7z873EHohpdCprhmhSUrCY6qI00wTp6SqfMWisxDv-HAkD-f8_bE43kHl9l-Yrv06Oz1xs25dQGcWQ_8VAaTjWxsKLUXBpbyGdiVsKU3Q7vzo494XyCFXKkpgZwmuRZ47mUqX1xGB0855XZPFWCEPjeyCVYJQsoTcmX0gjtScaPrH8tSr-N9CN9bNhb38bheL35aegzvo07bRmxMnZ7P1ys38j7_0HK_yVnfR7YGH4r1NlXtoJzb30bv9MSshbhM-A8Hl9jyuukv8bRNXW-LTBg9arEsMQVyc3dcms01sQa4D-O_y_AGaH7z9vH9IhkwLxGf3h5KQbGJRe-dK5Z1lVYieceqS0pX3oYpRuUhZSAL4mM0OOHVWZ-7ALechU7qHaNK0TXyEsMgfDUujCFFErlKuLJXzToekWMjPmaI32w42fpAhh2wYC5PdkR4nAzgZwMkATqYShppfOJmaG02n6OVo5mKjy3FVA68B3fFmkNnuC9ruxAz4GFX7KkgQGLKOl15YV3sWZS7VFau9nKJX49j4t2Y8_m8LT9DNfjhDPiX5FE1W3To-y0Rp5Z4Pc-MnPV8Pow |
openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Comparison+of+keratometry+versions+in+patients+with+corneal+astigmatism&rft.jtitle=Rossi%C4%ADski%C4%AD+oftal%CA%B9mologicheski%C4%AD+zhurnal&rft.au=Kulikov%2C+A.+N.&rft.au=Danilenko%2C+E.+V.&rft.au=Kozhevnikov%2C+E.+Yu&rft.date=2022-06-16&rft.issn=2072-0076&rft.eissn=2587-5760&rft.volume=15&rft.issue=2+%28%D0%9F%D1%80%D0%B8%D0%BB%29&rft.spage=84&rft.epage=92&rft_id=info:doi/10.21516%2F2072-0076-2022-15-2-supplement-84-92&rft.externalDBID=n%2Fa&rft.externalDocID=10_21516_2072_0076_2022_15_2_supplement_84_92 |
thumbnail_l | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=2072-0076&client=summon |
thumbnail_m | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=2072-0076&client=summon |
thumbnail_s | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=2072-0076&client=summon |