End-user verification results of two serum separator tubes for clinical chemistry analytes according to CLSI GP34-A and CLSI GP41-A6
Tube manufacturers use different composition of gels and blood clot activator formulations in serum tube production. Our aim was to investigate the within-tube (repeatability) and between-tube variation, concordance between comparison results of BD and VacuSEL tubes. Blood samples were collected fro...
Saved in:
| Published in | Scandinavian journal of clinical and laboratory investigation Vol. 84; no. 3; pp. 183 - 192 |
|---|---|
| Main Authors | , , , , , , , , |
| Format | Journal Article |
| Language | English |
| Published |
England
02.05.2024
|
| Subjects | |
| Online Access | Get full text |
| ISSN | 0036-5513 1502-7686 1502-7686 |
| DOI | 10.1080/00365513.2024.2344681 |
Cover
| Abstract | Tube manufacturers use different composition of gels and blood clot activator formulations in serum tube production. Our aim was to investigate the within-tube (repeatability) and between-tube variation, concordance between comparison results of BD and VacuSEL tubes. Blood samples were collected from control subjects (n = 20) and patients (n = 30) in accordance with the CLSI GP41-A6 and CLSI GP34-A guidelines. Twenty-three clinical chemistry parameters were analysed via Roche Cobas C702 Chemistry Analyzer on T0 (0 hour) and T24 (24 hour). Mean differences % were compared with Wilcoxon matched pair test. Clinical significance was evaluated based on desirable bias according to total allowable error (TEa). VacuSEL tubes demonstrated acceptable performance for the results of 20 parameters with regards to desirable bias % limits. Lactate dehydrogenase (LD) [mean difference % (%95 confidence intervals (CI) values of BD and VacuSEL tubes at T0 [6.41% (4.80-8.01%)]; sodium (Na) and total protein (TP) at T24 [-0.27% (-0.46 to -0.07%) and -1.39% (-1.87 to -0.91), respectively] were over the desirable bias limits (LD: 4.3%, Na: 0.23% and TP: 1.36%, respectively) but not exceeding total biological variation CV % [Na: 0.5 (0.0-1.0) % and TP: 2.6 (2.3-2.7) %). %95 confidence intervals (CI) of T0 LD values overlap with within-subject biological variation % (CI) limits (LD: 5.2 (4.9-5.4) %). The differences between two tubes were not medically significant and necessarily conclusive. VacuSEL serum tubes presented comparable performance with BD serum tubes. |
|---|---|
| AbstractList | Tube manufacturers use different composition of gels and blood clot activator formulations in serum tube production. Our aim was to investigate the within-tube (repeatability) and between-tube variation, concordance between comparison results of BD and VacuSEL tubes. Blood samples were collected from control subjects (n = 20) and patients (n = 30) in accordance with the CLSI GP41-A6 and CLSI GP34-A guidelines. Twenty-three clinical chemistry parameters were analysed via Roche Cobas C702 Chemistry Analyzer on T0 (0 hour) and T24 (24 hour). Mean differences % were compared with Wilcoxon matched pair test. Clinical significance was evaluated based on desirable bias according to total allowable error (TEa). VacuSEL tubes demonstrated acceptable performance for the results of 20 parameters with regards to desirable bias % limits. Lactate dehydrogenase (LD) [mean difference % (%95 confidence intervals (CI) values of BD and VacuSEL tubes at T0 [6.41% (4.80-8.01%)]; sodium (Na) and total protein (TP) at T24 [-0.27% (-0.46 to -0.07%) and -1.39% (-1.87 to -0.91), respectively] were over the desirable bias limits (LD: 4.3%, Na: 0.23% and TP: 1.36%, respectively) but not exceeding total biological variation CV % [Na: 0.5 (0.0-1.0) % and TP: 2.6 (2.3-2.7) %). %95 confidence intervals (CI) of T0 LD values overlap with within-subject biological variation % (CI) limits (LD: 5.2 (4.9-5.4) %). The differences between two tubes were not medically significant and necessarily conclusive. VacuSEL serum tubes presented comparable performance with BD serum tubes.Tube manufacturers use different composition of gels and blood clot activator formulations in serum tube production. Our aim was to investigate the within-tube (repeatability) and between-tube variation, concordance between comparison results of BD and VacuSEL tubes. Blood samples were collected from control subjects (n = 20) and patients (n = 30) in accordance with the CLSI GP41-A6 and CLSI GP34-A guidelines. Twenty-three clinical chemistry parameters were analysed via Roche Cobas C702 Chemistry Analyzer on T0 (0 hour) and T24 (24 hour). Mean differences % were compared with Wilcoxon matched pair test. Clinical significance was evaluated based on desirable bias according to total allowable error (TEa). VacuSEL tubes demonstrated acceptable performance for the results of 20 parameters with regards to desirable bias % limits. Lactate dehydrogenase (LD) [mean difference % (%95 confidence intervals (CI) values of BD and VacuSEL tubes at T0 [6.41% (4.80-8.01%)]; sodium (Na) and total protein (TP) at T24 [-0.27% (-0.46 to -0.07%) and -1.39% (-1.87 to -0.91), respectively] were over the desirable bias limits (LD: 4.3%, Na: 0.23% and TP: 1.36%, respectively) but not exceeding total biological variation CV % [Na: 0.5 (0.0-1.0) % and TP: 2.6 (2.3-2.7) %). %95 confidence intervals (CI) of T0 LD values overlap with within-subject biological variation % (CI) limits (LD: 5.2 (4.9-5.4) %). The differences between two tubes were not medically significant and necessarily conclusive. VacuSEL serum tubes presented comparable performance with BD serum tubes. Tube manufacturers use different composition of gels and blood clot activator formulations in serum tube production. Our aim was to investigate the within-tube (repeatability) and between-tube variation, concordance between comparison results of BD and VacuSEL tubes. Blood samples were collected from control subjects (n = 20) and patients (n = 30) in accordance with the CLSI GP41-A6 and CLSI GP34-A guidelines. Twenty-three clinical chemistry parameters were analysed via Roche Cobas C702 Chemistry Analyzer on T0 (0 hour) and T24 (24 hour). Mean differences % were compared with Wilcoxon matched pair test. Clinical significance was evaluated based on desirable bias according to total allowable error (TEa). VacuSEL tubes demonstrated acceptable performance for the results of 20 parameters with regards to desirable bias % limits. Lactate dehydrogenase (LD) [mean difference % (%95 confidence intervals (CI) values of BD and VacuSEL tubes at T0 [6.41% (4.80-8.01%)]; sodium (Na) and total protein (TP) at T24 [-0.27% (-0.46 to -0.07%) and -1.39% (-1.87 to -0.91), respectively] were over the desirable bias limits (LD: 4.3%, Na: 0.23% and TP: 1.36%, respectively) but not exceeding total biological variation CV % [Na: 0.5 (0.0-1.0) % and TP: 2.6 (2.3-2.7) %). %95 confidence intervals (CI) of T0 LD values overlap with within-subject biological variation % (CI) limits (LD: 5.2 (4.9-5.4) %). The differences between two tubes were not medically significant and necessarily conclusive. VacuSEL serum tubes presented comparable performance with BD serum tubes. |
| Author | Akyurek, Fikret Unlu, Ali Abusoglu, Gulsum Ecer, Busra Guven, Halil Yorulmaz, Ahmet Emre Abusoglu, Sedat Serdar, Muhittin Abdulkadir Ozturk, Bahadir |
| Author_xml | – sequence: 1 givenname: Sedat orcidid: 0000-0002-2984-0527 surname: Abusoglu fullname: Abusoglu, Sedat organization: Department of Biochemistry, Selcuk University, Faculty of Medicine, Konya, Turkey – sequence: 2 givenname: Busra surname: Ecer fullname: Ecer, Busra organization: Department of Biochemistry, Selcuk University, Faculty of Medicine, Konya, Turkey – sequence: 3 givenname: Halil surname: Guven fullname: Guven, Halil organization: Department of Biochemistry, Selcuk University, Faculty of Medicine, Konya, Turkey – sequence: 4 givenname: Ahmet Emre surname: Yorulmaz fullname: Yorulmaz, Ahmet Emre organization: Department of Biochemistry, Selcuk University, Faculty of Medicine, Konya, Turkey – sequence: 5 givenname: Muhittin Abdulkadir surname: Serdar fullname: Serdar, Muhittin Abdulkadir organization: Department of Biochemistry, Acıbadem University, Faculty of Medicine, İstanbul, Turkey – sequence: 6 givenname: Ali surname: Unlu fullname: Unlu, Ali organization: Department of Biochemistry, Selcuk University, Faculty of Medicine, Konya, Turkey – sequence: 7 givenname: Fikret surname: Akyurek fullname: Akyurek, Fikret organization: Department of Biochemistry, Selcuk University, Faculty of Medicine, Konya, Turkey – sequence: 8 givenname: Bahadir surname: Ozturk fullname: Ozturk, Bahadir organization: Department of Biochemistry, Selcuk University, Faculty of Medicine, Konya, Turkey – sequence: 9 givenname: Gulsum surname: Abusoglu fullname: Abusoglu, Gulsum organization: Department of Medical Laboratory Techniques, Selcuk University Vocational School of Health, Konya, Turkey |
| BackLink | https://www.ncbi.nlm.nih.gov/pubmed/38701073$$D View this record in MEDLINE/PubMed |
| BookMark | eNo9kctOwzAQRS0EgvL4BJCXbFLGsZ04y6riUakSSMA6cpwxBKVxsR1Q93w4rmjZzENzZjS695QcDm5AQi4ZTBkouAHghZSMT3PIxTTnQhSKHZAJk5BnZaGKQzLZMtkWOiGnIXxA6rkSx-SEqxIYlHxCfm6HNhsDevqFvrOd0bFzA_UYxj4G6iyN346m-bhKca29js7TODYYqE2V6bshLfXUvOOqC9FvqB50v4lpro1xvu2GNxodnS-fF_T-iYtsloh23wuWzYpzcmR1H_Bil8_I693ty_whWz7eL-azZWZyWcZMtYqphllZWC1lKVBYNAwbw7VArCCXXAJaMDm3HJSCilfAyqqRuqxYlfMzcv13d-3d54gh1ullg32vB3RjqDnItFMm1RJ6tUPHZoVtvfbdSvtNvVcuAfIPMN6F4NH-IwzqrUP13qF661C9c4j_Ai9KgRA |
| Cites_doi | 10.1093/clinchem/38.8.1474 10.1515/tjb-2018-0341 10.1373/clinchem.2005.055400 10.1371/journal.pone.0189882 10.1016/j.clinbiochem.2022.04.017 10.1373/clinchem.2006.069997 10.1016/j.cca.2019.06.013 10.11613/BM.2014.006 10.1093/clinchem/46.1.100 10.1016/j.cca.2023.117221 10.3343/alm.2021.41.1.114 10.1016/j.cca.2011.08.037 10.7754/Clin.Lab.2021.210841 10.1002/jcla.23060 10.1373/clinchem.2004.043349 10.1515/CCLM.2004.076 |
| ContentType | Journal Article |
| DBID | AAYXX CITATION CGR CUY CVF ECM EIF NPM 7X8 |
| DOI | 10.1080/00365513.2024.2344681 |
| DatabaseName | CrossRef Medline MEDLINE MEDLINE (Ovid) MEDLINE MEDLINE PubMed MEDLINE - Academic |
| DatabaseTitle | CrossRef MEDLINE Medline Complete MEDLINE with Full Text PubMed MEDLINE (Ovid) MEDLINE - Academic |
| DatabaseTitleList | MEDLINE - Academic MEDLINE |
| Database_xml | – sequence: 1 dbid: NPM name: PubMed url: https://proxy.k.utb.cz/login?url=http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed sourceTypes: Index Database – sequence: 2 dbid: EIF name: MEDLINE url: https://proxy.k.utb.cz/login?url=https://www.webofscience.com/wos/medline/basic-search sourceTypes: Index Database |
| DeliveryMethod | fulltext_linktorsrc |
| Discipline | Medicine |
| EISSN | 1502-7686 |
| EndPage | 192 |
| ExternalDocumentID | 38701073 10_1080_00365513_2024_2344681 |
| Genre | Journal Article |
| GroupedDBID | --- -~X 00X 03L 0R~ 123 36B 4.4 5RE AAGDL AALUX AAMIU AAPUL AAQRR AAWTL AAYXX ABBKH ABDBF ABEIZ ABJNI ABLIJ ABLJU ABLKL ABOCM ABUPF ABWVI ABXYU ACENM ACGEJ ACGFS ACIEZ ACUHS ADCVX ADRBQ ADXPE AECIN AENEX AEOZL AFKVX AFRVT AGDLA AGFJD AGRBW AGYJP AIJEM AIRBT AJWEG AKBVH ALMA_UNASSIGNED_HOLDINGS ALQZU ALYBC AMDAE BABNJ BLEHA BOHLJ CCCUG CITATION COF CS3 DKSSO DU5 EAP EAS EBB EBC EBD EBS EHN EMB EMK EMOBN EPL EPT ESX F5P H13 HZ~ KRBQP KSSTO KWAYT KYCEM L7B LJTGL M4Z O9- P2P Q~Q RNANH RVRKI SV3 TASJS TBQAZ TDBHL TERGH TFDNU TFL TFW TUROJ TUS UEQFS UHWXJ V1S WH7 ~1N .55 .GJ 34G 39C 3O- 53G 5VS AALIY AAORF AAPXX AAQQT ABWCV ABZEW ACKZS ACOPL ADFOM ADFZZ ADYSH AEIIZ AFFNX AFLEI AJVHN AWYRJ BRMBE CAG CGR CUY CVF CYYVM CZDIS DRXRE DWTOO EBX ECM EIF EJD JENTW M44 NPM NUSFT OVD QQXMO TEORI X7M ZGI ZXP 7X8 |
| ID | FETCH-LOGICAL-c257t-8d818b1f56fa5574e4fec1ebc3a4ee9025350ef0c23f308809390179b5a791923 |
| ISSN | 0036-5513 1502-7686 |
| IngestDate | Sun Aug 24 03:43:55 EDT 2025 Thu Apr 03 07:06:55 EDT 2025 Wed Oct 01 02:10:07 EDT 2025 |
| IsPeerReviewed | true |
| IsScholarly | true |
| Issue | 3 |
| Keywords | preanalytical effect laboratory Blood collection tubes clinical chemistry |
| Language | English |
| LinkModel | OpenURL |
| MergedId | FETCHMERGED-LOGICAL-c257t-8d818b1f56fa5574e4fec1ebc3a4ee9025350ef0c23f308809390179b5a791923 |
| Notes | ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 23 |
| ORCID | 0000-0002-2984-0527 |
| PMID | 38701073 |
| PQID | 3050937036 |
| PQPubID | 23479 |
| PageCount | 10 |
| ParticipantIDs | proquest_miscellaneous_3050937036 pubmed_primary_38701073 crossref_primary_10_1080_00365513_2024_2344681 |
| ProviderPackageCode | CITATION AAYXX |
| PublicationCentury | 2000 |
| PublicationDate | 2024-05-02 |
| PublicationDateYYYYMMDD | 2024-05-02 |
| PublicationDate_xml | – month: 05 year: 2024 text: 2024-05-02 day: 02 |
| PublicationDecade | 2020 |
| PublicationPlace | England |
| PublicationPlace_xml | – name: England |
| PublicationTitle | Scandinavian journal of clinical and laboratory investigation |
| PublicationTitleAlternate | Scand J Clin Lab Invest |
| PublicationYear | 2024 |
| References | e_1_3_7_21_1 e_1_3_7_20_1 CLSI (e_1_3_7_9_1) CLSI (e_1_3_7_11_1) CLSI (e_1_3_7_10_1) e_1_3_7_12_1 e_1_3_7_22_1 e_1_3_7_13_1 e_1_3_7_14_1 e_1_3_7_15_1 e_1_3_7_16_1 e_1_3_7_17_1 e_1_3_7_18_1 e_1_3_7_19_1 e_1_3_7_3_1 e_1_3_7_2_1 e_1_3_7_5_1 e_1_3_7_4_1 e_1_3_7_7_1 e_1_3_7_6_1 e_1_3_7_8_1 |
| References_xml | – ident: e_1_3_7_3_1 doi: 10.1093/clinchem/38.8.1474 – ident: e_1_3_7_16_1 doi: 10.1515/tjb-2018-0341 – ident: e_1_3_7_6_1 doi: 10.1373/clinchem.2005.055400 – ident: e_1_3_7_19_1 doi: 10.1371/journal.pone.0189882 – ident: e_1_3_7_20_1 doi: 10.1016/j.clinbiochem.2022.04.017 – ident: e_1_3_7_4_1 doi: 10.1373/clinchem.2006.069997 – ident: e_1_3_7_18_1 doi: 10.1016/j.cca.2019.06.013 – ident: e_1_3_7_7_1 doi: 10.11613/BM.2014.006 – ident: e_1_3_7_13_1 doi: 10.1093/clinchem/46.1.100 – ident: e_1_3_7_8_1 – ident: e_1_3_7_12_1 – ident: e_1_3_7_22_1 doi: 10.1016/j.cca.2023.117221 – ident: e_1_3_7_17_1 doi: 10.3343/alm.2021.41.1.114 – ident: e_1_3_7_21_1 doi: 10.1016/j.cca.2011.08.037 – volume-title: CLSI standard. GP41-A6 ident: e_1_3_7_9_1 – volume-title: Validation and verification of tubes for venous and capillary blood. Specimen collection; approved guideline. CLSI document GP34-A ident: e_1_3_7_10_1 – volume-title: Measurement procedure comparison and bias estimation using patient samples ident: e_1_3_7_11_1 – ident: e_1_3_7_15_1 doi: 10.7754/Clin.Lab.2021.210841 – ident: e_1_3_7_14_1 doi: 10.1002/jcla.23060 – ident: e_1_3_7_5_1 doi: 10.1373/clinchem.2004.043349 – ident: e_1_3_7_2_1 doi: 10.1515/CCLM.2004.076 |
| SSID | ssj0003384 |
| Score | 2.371937 |
| Snippet | Tube manufacturers use different composition of gels and blood clot activator formulations in serum tube production. Our aim was to investigate the within-tube... |
| SourceID | proquest pubmed crossref |
| SourceType | Aggregation Database Index Database |
| StartPage | 183 |
| SubjectTerms | Adult Aged Blood Chemical Analysis - instrumentation Blood Chemical Analysis - methods Blood Chemical Analysis - standards Blood Specimen Collection - instrumentation Blood Specimen Collection - methods Female Humans L-Lactate Dehydrogenase - blood Male Middle Aged Reproducibility of Results Sodium - blood |
| Title | End-user verification results of two serum separator tubes for clinical chemistry analytes according to CLSI GP34-A and CLSI GP41-A6 |
| URI | https://www.ncbi.nlm.nih.gov/pubmed/38701073 https://www.proquest.com/docview/3050937036 |
| Volume | 84 |
| hasFullText | 1 |
| inHoldings | 1 |
| isFullTextHit | |
| isPrint | |
| journalDatabaseRights | – providerCode: PRVEBS databaseName: Academic Search Ultimate - eBooks customDbUrl: https://search.ebscohost.com/login.aspx?authtype=ip,shib&custid=s3936755&profile=ehost&defaultdb=asn eissn: 1502-7686 dateEnd: 20241102 omitProxy: true ssIdentifier: ssj0003384 issn: 0036-5513 databaseCode: ABDBF dateStart: 19980519 isFulltext: true titleUrlDefault: https://search.ebscohost.com/direct.asp?db=asn providerName: EBSCOhost |
| link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV1bb9MwFLZKJyFeEHfKTUZCvESpkthJm8d0tCuoG0hrpb5FtuOMSW0z2nhIPPPL-GUcO07SiSINXqzGbeIk5-u5-VwQesdiSvlQRG5OA-nSjIVuPMy4G3AQD_BHj6RJpD09i6YL-mkZLjudX3tRS6rkffHjYF7J_1AV5oCuOkv2HyjbXBQm4DPQF0agMIy3ovF4k7nay-DAneuQn4qYYECrVRWiUX4vHPherWE0Rb51TKHi0hRhaLMiRd31zWG6Rol2xTKhzVKTS1U4x7Pzj87JF0LdxGw22GPqu0m0r92eC5Mkw64vrXvfqrrNQvpkCzu9t3_ZFvloowESrnbFxUoZv6zMWBOXMxYVvEZqt22EyYm6rhjnFAyKVcvDtmq1ZsY5nnxdy9IZr22Ur_VwBNTEEwb7TBm4NphFtmT2gTnLyatmcxaxZI8t-1WznD_ERR1fSSLd56avF-8HBCzkqo3MzfLcZ5_TyWI2S-fj5fz91TdXdy7TO_y2jcsddBSAZPG66CgZfRhNGn2AENP3urnjOo9MV3g_tPJNDekvZo9Rf-YP0H1rt-CkAuFD1JGbR-juqY3MeIx-1ljE-1jEFou4yDFgERss4gaL2GARAxZxDRHcYBHXWMQNFnFZYI09XGERfpHVxwaLT9BiMp4fT13b4cMVICpKd5iBvsj9PIxyFoYDKmkuhS-5IIxKqXfASejJ3BMByQnIQy_WLrpBzEM2iLVt8hR1N8VGPkc4JzxjnNEwz0HJ9uTQE0ywcOiFgoQ05j3Ur99qelUVckn9tj6uIUOqyZBaMvTQ2_rdp_Dceh-NbWShdinRNZOIrlzXQ88qojSXJCD_fBCbL25x9kt0r4X7K9Qtt0q-BhW35G8shn4DmhCmuQ |
| linkProvider | EBSCOhost |
| openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=End-user+verification+results+of+two+serum+separator+tubes+for+clinical+chemistry+analytes+according+to+CLSI+GP34-A+and+CLSI+GP41-A6&rft.jtitle=Scandinavian+journal+of+clinical+and+laboratory+investigation&rft.au=Abusoglu%2C+Sedat&rft.au=Ecer%2C+Busra&rft.au=Guven%2C+Halil&rft.au=Yorulmaz%2C+Ahmet+Emre&rft.date=2024-05-02&rft.issn=1502-7686&rft.eissn=1502-7686&rft.volume=84&rft.issue=3&rft.spage=183&rft_id=info:doi/10.1080%2F00365513.2024.2344681&rft.externalDBID=NO_FULL_TEXT |
| thumbnail_l | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=0036-5513&client=summon |
| thumbnail_m | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=0036-5513&client=summon |
| thumbnail_s | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=0036-5513&client=summon |