A New Approach to the Calculation of the Lightning Performance of Transmission Lines [includes discussion]
Saved in:
| Published in | Transactions of the American Institute of Electrical Engineers. Part 3, Power apparatus and systems Vol. 75; no. 3; pp. 1233 - 1256 |
|---|---|
| Main Author | |
| Format | Journal Article |
| Language | English |
| Published |
IEEE
01.01.1956
|
| Subjects | |
| Online Access | Get full text |
| ISSN | 0097-2460 |
| DOI | 10.1109/AIEEPAS.1956.4499430 |
Cover
| Author | Wagner, C. F. |
|---|---|
| Author_xml | – sequence: 1 givenname: C. F. surname: Wagner fullname: Wagner, C. F. organization: FELLOW AIEE, Westinghouse Electric Corporation, East Pittsburgh, Pa |
| BookMark | eNqFkM9OwzAMh3MYEhvwBHDIC3QkTfon3KppwKQKJjFOCFXBdbdMXTolmRBvz7oNDlw42fLnny19IzKwnUVCbjgbc87UbTGbTufFy5irJB1LqZQUbECGjKksimXKzsnI-zVjgqc5G5J1QZ_wkxbbres0rGjoaFghnegWdq0OprO0aw6j0ixXwRq7pHN0Tec22gL2cOG09Rvjfb9cGouevhkL7a7ed7XxsDug90ty1ujW49WpXpDX--li8hiVzw-zSVFGECcsRIIDSJmnmCDoDDOZxwowAak4ZB8psD2shdAqr7UUHOOmUcBTrAXDpI4TcUHk8S64znuHTbV1ZqPdV8VZ1TuqTo6q3lF1crSP3f2JgQkHA8Fp0_4Xvj6GDSL-_vuh31Vqe5o |
| CitedBy_id | crossref_primary_10_1109_TPWRD_2015_2408320 crossref_primary_10_1016_j_epsr_2012_05_020 crossref_primary_10_1007_s40313_015_0198_y crossref_primary_10_1002_tee_22260 crossref_primary_10_1016_0016_0032_67_90601_1 crossref_primary_10_1016_j_elstat_2012_08_002 crossref_primary_10_1109_TPWRD_2004_839189 |
| Cites_doi | 10.1109/T-AIEE.1941.5058410 10.1109/T-AIEE.1941.5058256 10.1109/T-AIEE.1942.5058463 10.1109/T-AIEE.1949.5059957 10.1049/ji-1.1941.0043 10.1016/0016-0032(52)90717-5 10.1098/rspa.1953.0169 10.1049/ji-1.1941.0051 10.1109/AIEEPAS.1956.4499344 |
| ContentType | Journal Article |
| DBID | AAYXX CITATION |
| DOI | 10.1109/AIEEPAS.1956.4499430 |
| DatabaseName | CrossRef |
| DatabaseTitle | CrossRef |
| DeliveryMethod | fulltext_linktorsrc |
| Discipline | Engineering |
| EndPage | 1256 |
| ExternalDocumentID | 10_1109_AIEEPAS_1956_4499430 4499430 |
| Genre | orig-research |
| GroupedDBID | 0R~ 29O 6IK AAJGR AAWTH ABAZT ABQJQ ABVLG ACGFS AGQYO AHBIQ ALLEH ALMA_UNASSIGNED_HOLDINGS BEFXN BFFAM BGNUA BKEBE BPEOZ EBS IDIHD IEQBH IFIPE IPLJI JAVBF M43 OCL RIE RNS AAYXX CITATION |
| ID | FETCH-LOGICAL-c250t-31cc4486e5eca7e74829ce5c491c7b6c0448d33a98da431e2ff9c16ed30e5d253 |
| IEDL.DBID | RIE |
| ISSN | 0097-2460 |
| IngestDate | Thu Apr 24 23:12:38 EDT 2025 Tue Jul 01 01:21:05 EDT 2025 Wed Aug 27 02:48:17 EDT 2025 |
| IsPeerReviewed | false |
| IsScholarly | false |
| Issue | 3 |
| Language | English |
| License | https://ieeexplore.ieee.org/Xplorehelp/downloads/license-information/IEEE.html |
| LinkModel | DirectLink |
| MergedId | FETCHMERGED-LOGICAL-c250t-31cc4486e5eca7e74829ce5c491c7b6c0448d33a98da431e2ff9c16ed30e5d253 |
| PageCount | 24 |
| ParticipantIDs | crossref_primary_10_1109_AIEEPAS_1956_4499430 ieee_primary_4499430 crossref_citationtrail_10_1109_AIEEPAS_1956_4499430 |
| ProviderPackageCode | CITATION AAYXX |
| PublicationCentury | 1900 |
| PublicationDate | 1956-Jan. 1956-01-00 |
| PublicationDateYYYYMMDD | 1956-01-01 |
| PublicationDate_xml | – month: 01 year: 1956 text: 1956-Jan. |
| PublicationDecade | 1950 |
| PublicationTitle | Transactions of the American Institute of Electrical Engineers. Part 3, Power apparatus and systems |
| PublicationTitleAbbrev | AIEEPAS |
| PublicationYear | 1956 |
| Publisher | IEEE |
| Publisher_xml | – name: IEEE |
| References | schonland (ref10) 1938; 164 ref13 ref12 schonland (ref9) 1935; 152 ref14 bewley (ref7) 1937; 40 ref11 (ref15) 1936; 39 ref1 ref17 fortescue (ref4) 1930; 27 ref16 razevig (ref1s) 1949; 12 ref18 ref8 (ref2) 0 (ref3) 0 monteith (ref6) 1934 fortescue (ref5) 1931; 50 |
| References_xml | – ident: ref13 doi: 10.1109/T-AIEE.1941.5058410 – volume: 50 start-page: 1090 year: 1931 ident: ref5 article-title: Lightning Discharges and Line Protective Measures publication-title: AIEE Transactions – volume: 40 start-page: 180 year: 1937 ident: ref7 publication-title: General Electric Review – ident: ref14 doi: 10.1109/T-AIEE.1941.5058256 – ident: ref18 doi: 10.1109/T-AIEE.1942.5058463 – ident: ref8 doi: 10.1109/T-AIEE.1949.5059957 – ident: ref17 doi: 10.1049/ji-1.1941.0043 – volume: 27 start-page: 459 year: 1930 ident: ref4 article-title: Direct STROKES-NOT Induced Surges? Chief Cause of HIGH-VOLTAGE FLASHOVER publication-title: The Electric Journal – volume: 39 year: 1936 ident: ref15 publication-title: General Electric Review – volume: 152 start-page: 595 year: 1935 ident: ref9 article-title: Progressive Lightning?ii publication-title: Proceedings – ident: ref16 doi: 10.1016/0016-0032(52)90717-5 – ident: ref11 doi: 10.1098/rspa.1953.0169 – volume: 164 start-page: 132 year: 1938 ident: ref10 article-title: Progressive Lightning?iv publication-title: Proceedings – year: 0 ident: ref2 – year: 0 ident: ref3 – start-page: 72 year: 1934 ident: ref6 article-title: Transmission Line Design Estimates? Simplified publication-title: The Electric Journal – ident: ref12 doi: 10.1049/ji-1.1941.0051 – ident: ref1 doi: 10.1109/AIEEPAS.1956.4499344 – volume: 12 start-page: 31 year: 1949 ident: ref1s publication-title: Elektrichestvo |
| SSID | ssj0031680 |
| Score | 1.1565688 |
| SourceID | crossref ieee |
| SourceType | Enrichment Source Index Database Publisher |
| StartPage | 1233 |
| SubjectTerms | Conductors Flashover Impedance Inductance Insulation Lightning Poles and towers Surges Transmission lines Wires |
| Title | A New Approach to the Calculation of the Lightning Performance of Transmission Lines [includes discussion] |
| URI | https://ieeexplore.ieee.org/document/4499430 |
| Volume | 75 |
| hasFullText | 1 |
| inHoldings | 1 |
| isFullTextHit | |
| isPrint | |
| journalDatabaseRights | – providerCode: PRVIEE databaseName: IEEE Electronic Library (IEL) issn: 0097-2460 databaseCode: RIE dateStart: 19520101 customDbUrl: isFulltext: true dateEnd: 19621231 titleUrlDefault: https://ieeexplore.ieee.org/ omitProxy: false ssIdentifier: ssj0031680 providerName: IEEE |
| link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwjV3dS8MwEA9zT_rg1xTnF3nw0XbdkqbLYxnKECcDHQxESppeQR2tSPviX-8lzeYUQd9CcimhFy73u-R3R8hFkDMEXKiBPJPC47KvPclU4EmNaIIbboit3jC5E-MZv5mH8xa5XHFhAMA-PgPfNO1dflbq2oTKehzdc84QoG9EQ9FwtZZW19RfaugmMvIGXASOJtcPZC9G3DSN731DjfPdN74dQ2t1Veyxcr1DJssFNa9JXv26Sn398SNX439XvEu2nX9J42ZD7JEWFPtkay3rYIe8xBRNG41dNnFalRS9QDpSC-1qedEyt123BrmbwAmdfvELzKA94XCHmFAbSqG5pI_PhV7UGbYM0be2Q08HZHZ99TAae67kgqfRF6rQImuNgE1ACFpFEPHhQGoItVFilAod4GDGmJLDTKHrAYM8l7ovIGMBhNkgZIekXZQFHBEqVZ7mqZCIRxjnKai-TsMQQCgVqkjmXcKWGki0y0duymIsEotLApk4vSVGb4n7k13irWa9Nfk4_pDvGK2sZF338e_dJ2TTTG5CLKekXb3XcIZOR5We2932CXk40yI |
| linkProvider | IEEE |
| linkToHtml | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwjV3dS8MwEA9DH9QHv8X5mQcfbe2WpF0ey3BM3cZABwORkqZXUMcm0r7413tJszlF0LeQXEPohcv9LvndEXIR5AwBF2ogz2TocdnQnmQq8KRGNMENN8RWb-gPwu6I347FuEYuF1wYALCPz8A3TXuXn810aUJlVxzdc84QoK8Kzrmo2Fpzu2sqMFWEExl5TR4GjijXCORVjMhpGN_7hhznu1m-HURLlVXswdLZIv35kqr3JK9-WaS-_viRrfG_a94mm87DpHG1JXZIDaa7ZGMp7-AeeYkpGjcau3zitJhR9ANpW020q-ZFZ7nt6hnsbkIndPjFMDCD9ozDPWKCbSiFBpM-Pk_1pMywZai-pR162iejzvVDu-u5ogueRm-oQJusNUK2EARoFUHEW02pQWijxigNdYCDGWNKtjKFzgc081zqRggZC0BkTcEOyMp0NoVDQqXK0zwNJSISxnkKqqFTIQBCpYSKZF4nbK6BRLuM5KYwxiSxyCSQidNbYvSWuD9ZJ97iq7cqI8cf8ntGKwtZ1330e_c5Wes-9HtJ72Zwd0zWzURVwOWErBTvJZyiC1KkZ3bnfQKu9tZv |
| openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=A+New+Approach+to+the+Calculation+of+the+Lightning+Performance+of+Transmission+Lines+%5Bincludes+discussion%5D&rft.jtitle=Transactions+of+the+American+Institute+of+Electrical+Engineers.+Part+3%2C+Power+apparatus+and+systems&rft.au=Wagner%2C+C.+F.&rft.date=1956-01-01&rft.issn=0097-2460&rft.volume=75&rft.issue=3&rft_id=info:doi/10.1109%2FAIEEPAS.1956.4499430&rft.externalDBID=n%2Fa&rft.externalDocID=10_1109_AIEEPAS_1956_4499430 |
| thumbnail_l | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=0097-2460&client=summon |
| thumbnail_m | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=0097-2460&client=summon |
| thumbnail_s | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=0097-2460&client=summon |