Evaluation of pulmonary function data using computer time-sharing

Evaluation of disturbances in lung function requires a variety of physiological measurements. Absolute values for such determinations are meaningless because the significance of the measured quantities varies with the age, sex, and body size of the subject. At present the norm which is compared with...

Full description

Saved in:
Bibliographic Details
Published inProceedings of the IEEE Vol. 57; no. 11; pp. 1996 - 1999
Main Authors Sullivan, S.F., Patterson, R.W., Papper, E.M.
Format Journal Article
LanguageEnglish
Published IEEE 01.01.1969
Subjects
Online AccessGet full text
ISSN0018-9219
DOI10.1109/PROC.1969.7445

Cover

Abstract Evaluation of disturbances in lung function requires a variety of physiological measurements. Absolute values for such determinations are meaningless because the significance of the measured quantities varies with the age, sex, and body size of the subject. At present the norm which is compared with the measured value must be derived from tables or in some instances must be individually calculated. A computer program has been developed which evaluates the measured values of lung function by comparing them with accepted norms. The computer program is written in the BASIC programming language and minimal involvement by laboratory personnel is required. Stored in the computer program are matrices containing the regression coefficients used for the computation of the predicted values for each of the pulmonary function tests based upon the patient's sex, height, age, and weight. When the measured value falls outside of the 95 percent confidence limits, the measured value is flagged on a computer printout, immediately denoting those values which are abnormal. In approximately 5 minutes after the input of data, the printout evaluation is available for addition to the patient's record.
AbstractList Evaluation of disturbances in lung function requires a variety of physiological measurements. Absolute values for such determinations are meaningless because the significance of the measured quantities varies with the age, sex, and body size of the subject. At present the norm which is compared with the measured value must be derived from tables or in some instances must be individually calculated. A computer program has been developed which evaluates the measured values of lung function by comparing them with accepted norms. The computer program is written in the BASIC programming language and minimal involvement by laboratory personnel is required. Stored in the computer program are matrices containing the regression coefficients used for the computation of the predicted values for each of the pulmonary function tests based upon the patient's sex, height, age, and weight. When the measured value falls outside of the 95 percent confidence limits, the measured value is flagged on a computer printout, immediately denoting those values which are abnormal. In approximately 5 minutes after the input of data, the printout evaluation is available for addition to the patient's record.
Author Patterson, R.W.
Papper, E.M.
Sullivan, S.F.
Author_xml – sequence: 1
  givenname: S.F.
  surname: Sullivan
  fullname: Sullivan, S.F.
  organization: Columbia University College of Physicians and Surgeons, New York, NY
– sequence: 2
  givenname: R.W.
  surname: Patterson
  fullname: Patterson, R.W.
– sequence: 3
  givenname: E.M.
  surname: Papper
  fullname: Papper, E.M.
BookMark eNpFj0tLw0AUhWdRwba6deMmfyBx7jwymWUJ9QGFiuh6uJncaCQvMongv7exgqsDh3MO59uwVdd3xNgN8ASA27vnl2OegE1tYpTSK7bmHLLYCrCXbBPCJ-dc6lSu2W7_hc2MU913UV9Fw9y0fYfjd1TNnf91S5wwmkPdvUe-b4d5ojGa6pbi8IHjyb1iFxU2ga7_dMve7vev-WN8OD485btD7AWIKcZMpZkCKkFjZqAS6A0YEmUhyXAio0qZkuRoQWtdeIXCcm2K0lcys5LLLUvOu37sQxipcsNYt6erDrhboN0C7RZot0CfCrfnQk1E_2GlrDRa_gBtLVd3
CODEN IEEPAD
ContentType Journal Article
DBID AAYXX
CITATION
DOI 10.1109/PROC.1969.7445
DatabaseName CrossRef
DatabaseTitle CrossRef
DatabaseTitleList
DeliveryMethod fulltext_linktorsrc
Discipline Engineering
EndPage 1999
ExternalDocumentID 10_1109_PROC_1969_7445
1449375
Genre orig-research
GroupedDBID -DZ
-~X
.DC
0R~
123
1OL
29P
3EH
4.4
6IK
85S
9M8
AAJGR
AAWTH
ABAZT
ABFSI
ABJNI
ABQJQ
ABVLG
ACBEA
ACGFS
AENEX
AETEA
AETIX
AFOGA
AGNAY
AGQYO
AGSQL
AHBIQ
AIBXA
ALLEH
ALMA_UNASSIGNED_HOLDINGS
AZLTO
BEFXN
BFFAM
BGNUA
BKEBE
BPEOZ
CS3
DU5
EBS
EJD
FA8
HZ~
H~9
IAAWW
IBMZZ
ICLAB
IDIHD
IFIPE
IFJZH
IPLJI
JAVBF
LAI
M43
MVM
O9-
OCL
RIE
RIU
RNS
TAE
TN5
TWZ
UDY
UHB
UKR
UQL
VOH
WHG
XJT
XOL
YNT
ZCA
ZXP
ZY4
~02
AAYXX
CITATION
ID FETCH-LOGICAL-c212t-a846841ed15a871f2ac717e2db3e70ee74d36e30a91555bc4a29057bdcf389303
IEDL.DBID RIE
ISSN 0018-9219
IngestDate Wed Oct 01 02:40:36 EDT 2025
Wed Aug 27 02:43:10 EDT 2025
IsPeerReviewed true
IsScholarly true
Issue 11
Language English
License https://ieeexplore.ieee.org/Xplorehelp/downloads/license-information/IEEE.html
LinkModel DirectLink
MergedId FETCHMERGED-LOGICAL-c212t-a846841ed15a871f2ac717e2db3e70ee74d36e30a91555bc4a29057bdcf389303
PageCount 4
ParticipantIDs crossref_primary_10_1109_PROC_1969_7445
ieee_primary_1449375
ProviderPackageCode CITATION
AAYXX
PublicationCentury 1900
PublicationDate 1969-01-01
PublicationDateYYYYMMDD 1969-01-01
PublicationDate_xml – month: 01
  year: 1969
  text: 1969-01-01
  day: 01
PublicationDecade 1960
PublicationTitle Proceedings of the IEEE
PublicationTitleAbbrev JPROC
PublicationYear 1969
Publisher IEEE
Publisher_xml – name: IEEE
SSID ssj0003563
Score 1.2025094
Snippet Evaluation of disturbances in lung function requires a variety of physiological measurements. Absolute values for such determinations are meaningless because...
SourceID crossref
ieee
SourceType Index Database
Publisher
StartPage 1996
SubjectTerms Blood
Computer languages
Diseases
Laboratories
Lungs
Personnel
Size measurement
Testing
Time sharing computer systems
Ventilation
Title Evaluation of pulmonary function data using computer time-sharing
URI https://ieeexplore.ieee.org/document/1449375
Volume 57
hasFullText 1
inHoldings 1
isFullTextHit
isPrint
journalDatabaseRights – providerCode: PRVIEE
  databaseName: IEEE Xplore
  issn: 0018-9219
  databaseCode: RIE
  dateStart: 19630101
  customDbUrl:
  isFulltext: true
  dateEnd: 99991231
  titleUrlDefault: https://ieeexplore.ieee.org/
  omitProxy: false
  ssIdentifier: ssj0003563
  providerName: IEEE
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwjV1LS8NAEB7anvTgq4r1xR4ELybNYzfZHEtpKUJVxEJvYXczVVDaUpOD_npnk7QW8eAtLElY5pH5ZjPzDcC1UglXmQydmAtKUGKpHMmFdgJjTIYU8sJy8tz4PhpN-N1UTBtwu-mFQcSy-Axde1n-y88WprBHZV0C_xRNRROasYyqXq3NVzcU9dQ0nxyY3LAmaPS9pPv49NB3LQ2MG3PbtrQVgLYmqpQBZbgP4_VWqjqSN7fItWu-frE0_nevB7BXI0vWq0zhEBo4P4LdLb7BNvQGG25vtpixZfFORqhWn8xGt3LVFowyWwv_wkw974HZ8fPOx6uy7ziGyXDw3B859QwFx1BQyh1F-EJyHzNfKMqNZoEylMBhkOkQYw8x5lkYYegpyxMvtOEqSAjC6czMLJTxwhNozRdzPAXmR8ZHGUmFUnNydU1ILPJIp5EQRgfYgZu1YNNlRZWRlimGl6RWBalVQWpV0IG2FdjPXZWszv5ePocd-2R17nEBrXxV4CUhgVxflSbwDbJnsO4
linkProvider IEEE
linkToHtml http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwjV1LT8JAEJ4gHtSDLzTiswcTL7b0sdvHkRAIKqAxkHBrdreDJhog2B701zvbFiTGg7dm02w28-h8s535BuBaiIiJJPTMgHFKUIJQmCHj0nSVUglSyPPyyXP9gd8dsfsxH1fgdtULg4h58Rla-jH_l5_MVKavyhoE_ima8g3Y5IwxXnRrrb67Hi_npjnkwuSIJUWjY0eNp-fHlqWJYKyA6caltRC0NlMlDymdPegvD1NUkrxZWSot9fWLp_G_p92H3RJbGs3CGA6ggtND2FljHKxBs71i9zZmE2OevZMZisWnoeNbvqpLRg1dDf9iqHLig6EH0Jsfr0LvcQSjTnvY6prlFAVTUVhKTUEII2QOJg4XlB1NXKEohUM3kR4GNmLAEs9HzxaaKZ5LxYQbEYiTiZpoMGN7x1CdzqZ4AobjKwdDPxQYSkbOLgmL-TZp1edcSRfrcLMUbDwvyDLiPMmwo1irINYqiLUK6lDTAvt5q5DV6d_LV7DVHfZ7ce9u8HAG23qX4hbkHKrpIsMLwgWpvMzN4RsmB7Q7
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Evaluation+of+pulmonary+function+data+using+computer+time-sharing&rft.jtitle=Proceedings+of+the+IEEE&rft.au=Sullivan%2C+S.F.&rft.au=Patterson%2C+R.W.&rft.au=Papper%2C+E.M.&rft.date=1969-01-01&rft.pub=IEEE&rft.issn=0018-9219&rft.volume=57&rft.issue=11&rft.spage=1996&rft.epage=1999&rft_id=info:doi/10.1109%2FPROC.1969.7445&rft.externalDocID=1449375
thumbnail_l http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=0018-9219&client=summon
thumbnail_m http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=0018-9219&client=summon
thumbnail_s http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=0018-9219&client=summon