Evaluation of pulmonary function data using computer time-sharing
Evaluation of disturbances in lung function requires a variety of physiological measurements. Absolute values for such determinations are meaningless because the significance of the measured quantities varies with the age, sex, and body size of the subject. At present the norm which is compared with...
Saved in:
| Published in | Proceedings of the IEEE Vol. 57; no. 11; pp. 1996 - 1999 |
|---|---|
| Main Authors | , , |
| Format | Journal Article |
| Language | English |
| Published |
IEEE
01.01.1969
|
| Subjects | |
| Online Access | Get full text |
| ISSN | 0018-9219 |
| DOI | 10.1109/PROC.1969.7445 |
Cover
| Abstract | Evaluation of disturbances in lung function requires a variety of physiological measurements. Absolute values for such determinations are meaningless because the significance of the measured quantities varies with the age, sex, and body size of the subject. At present the norm which is compared with the measured value must be derived from tables or in some instances must be individually calculated. A computer program has been developed which evaluates the measured values of lung function by comparing them with accepted norms. The computer program is written in the BASIC programming language and minimal involvement by laboratory personnel is required. Stored in the computer program are matrices containing the regression coefficients used for the computation of the predicted values for each of the pulmonary function tests based upon the patient's sex, height, age, and weight. When the measured value falls outside of the 95 percent confidence limits, the measured value is flagged on a computer printout, immediately denoting those values which are abnormal. In approximately 5 minutes after the input of data, the printout evaluation is available for addition to the patient's record. |
|---|---|
| AbstractList | Evaluation of disturbances in lung function requires a variety of physiological measurements. Absolute values for such determinations are meaningless because the significance of the measured quantities varies with the age, sex, and body size of the subject. At present the norm which is compared with the measured value must be derived from tables or in some instances must be individually calculated. A computer program has been developed which evaluates the measured values of lung function by comparing them with accepted norms. The computer program is written in the BASIC programming language and minimal involvement by laboratory personnel is required. Stored in the computer program are matrices containing the regression coefficients used for the computation of the predicted values for each of the pulmonary function tests based upon the patient's sex, height, age, and weight. When the measured value falls outside of the 95 percent confidence limits, the measured value is flagged on a computer printout, immediately denoting those values which are abnormal. In approximately 5 minutes after the input of data, the printout evaluation is available for addition to the patient's record. |
| Author | Patterson, R.W. Papper, E.M. Sullivan, S.F. |
| Author_xml | – sequence: 1 givenname: S.F. surname: Sullivan fullname: Sullivan, S.F. organization: Columbia University College of Physicians and Surgeons, New York, NY – sequence: 2 givenname: R.W. surname: Patterson fullname: Patterson, R.W. – sequence: 3 givenname: E.M. surname: Papper fullname: Papper, E.M. |
| BookMark | eNpFj0tLw0AUhWdRwba6deMmfyBx7jwymWUJ9QGFiuh6uJncaCQvMongv7exgqsDh3MO59uwVdd3xNgN8ASA27vnl2OegE1tYpTSK7bmHLLYCrCXbBPCJ-dc6lSu2W7_hc2MU913UV9Fw9y0fYfjd1TNnf91S5wwmkPdvUe-b4d5ojGa6pbi8IHjyb1iFxU2ga7_dMve7vev-WN8OD485btD7AWIKcZMpZkCKkFjZqAS6A0YEmUhyXAio0qZkuRoQWtdeIXCcm2K0lcys5LLLUvOu37sQxipcsNYt6erDrhboN0C7RZot0CfCrfnQk1E_2GlrDRa_gBtLVd3 |
| CODEN | IEEPAD |
| ContentType | Journal Article |
| DBID | AAYXX CITATION |
| DOI | 10.1109/PROC.1969.7445 |
| DatabaseName | CrossRef |
| DatabaseTitle | CrossRef |
| DatabaseTitleList | |
| DeliveryMethod | fulltext_linktorsrc |
| Discipline | Engineering |
| EndPage | 1999 |
| ExternalDocumentID | 10_1109_PROC_1969_7445 1449375 |
| Genre | orig-research |
| GroupedDBID | -DZ -~X .DC 0R~ 123 1OL 29P 3EH 4.4 6IK 85S 9M8 AAJGR AAWTH ABAZT ABFSI ABJNI ABQJQ ABVLG ACBEA ACGFS AENEX AETEA AETIX AFOGA AGNAY AGQYO AGSQL AHBIQ AIBXA ALLEH ALMA_UNASSIGNED_HOLDINGS AZLTO BEFXN BFFAM BGNUA BKEBE BPEOZ CS3 DU5 EBS EJD FA8 HZ~ H~9 IAAWW IBMZZ ICLAB IDIHD IFIPE IFJZH IPLJI JAVBF LAI M43 MVM O9- OCL RIE RIU RNS TAE TN5 TWZ UDY UHB UKR UQL VOH WHG XJT XOL YNT ZCA ZXP ZY4 ~02 AAYXX CITATION |
| ID | FETCH-LOGICAL-c212t-a846841ed15a871f2ac717e2db3e70ee74d36e30a91555bc4a29057bdcf389303 |
| IEDL.DBID | RIE |
| ISSN | 0018-9219 |
| IngestDate | Wed Oct 01 02:40:36 EDT 2025 Wed Aug 27 02:43:10 EDT 2025 |
| IsPeerReviewed | true |
| IsScholarly | true |
| Issue | 11 |
| Language | English |
| License | https://ieeexplore.ieee.org/Xplorehelp/downloads/license-information/IEEE.html |
| LinkModel | DirectLink |
| MergedId | FETCHMERGED-LOGICAL-c212t-a846841ed15a871f2ac717e2db3e70ee74d36e30a91555bc4a29057bdcf389303 |
| PageCount | 4 |
| ParticipantIDs | crossref_primary_10_1109_PROC_1969_7445 ieee_primary_1449375 |
| ProviderPackageCode | CITATION AAYXX |
| PublicationCentury | 1900 |
| PublicationDate | 1969-01-01 |
| PublicationDateYYYYMMDD | 1969-01-01 |
| PublicationDate_xml | – month: 01 year: 1969 text: 1969-01-01 day: 01 |
| PublicationDecade | 1960 |
| PublicationTitle | Proceedings of the IEEE |
| PublicationTitleAbbrev | JPROC |
| PublicationYear | 1969 |
| Publisher | IEEE |
| Publisher_xml | – name: IEEE |
| SSID | ssj0003563 |
| Score | 1.2025094 |
| Snippet | Evaluation of disturbances in lung function requires a variety of physiological measurements. Absolute values for such determinations are meaningless because... |
| SourceID | crossref ieee |
| SourceType | Index Database Publisher |
| StartPage | 1996 |
| SubjectTerms | Blood Computer languages Diseases Laboratories Lungs Personnel Size measurement Testing Time sharing computer systems Ventilation |
| Title | Evaluation of pulmonary function data using computer time-sharing |
| URI | https://ieeexplore.ieee.org/document/1449375 |
| Volume | 57 |
| hasFullText | 1 |
| inHoldings | 1 |
| isFullTextHit | |
| isPrint | |
| journalDatabaseRights | – providerCode: PRVIEE databaseName: IEEE Xplore issn: 0018-9219 databaseCode: RIE dateStart: 19630101 customDbUrl: isFulltext: true dateEnd: 99991231 titleUrlDefault: https://ieeexplore.ieee.org/ omitProxy: false ssIdentifier: ssj0003563 providerName: IEEE |
| link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwjV1LS8NAEB7anvTgq4r1xR4ELybNYzfZHEtpKUJVxEJvYXczVVDaUpOD_npnk7QW8eAtLElY5pH5ZjPzDcC1UglXmQydmAtKUGKpHMmFdgJjTIYU8sJy8tz4PhpN-N1UTBtwu-mFQcSy-Axde1n-y88WprBHZV0C_xRNRROasYyqXq3NVzcU9dQ0nxyY3LAmaPS9pPv49NB3LQ2MG3PbtrQVgLYmqpQBZbgP4_VWqjqSN7fItWu-frE0_nevB7BXI0vWq0zhEBo4P4LdLb7BNvQGG25vtpixZfFORqhWn8xGt3LVFowyWwv_wkw974HZ8fPOx6uy7ziGyXDw3B859QwFx1BQyh1F-EJyHzNfKMqNZoEylMBhkOkQYw8x5lkYYegpyxMvtOEqSAjC6czMLJTxwhNozRdzPAXmR8ZHGUmFUnNydU1ILPJIp5EQRgfYgZu1YNNlRZWRlimGl6RWBalVQWpV0IG2FdjPXZWszv5ePocd-2R17nEBrXxV4CUhgVxflSbwDbJnsO4 |
| linkProvider | IEEE |
| linkToHtml | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwjV1LT8JAEJ4gHtSDLzTiswcTL7b0sdvHkRAIKqAxkHBrdreDJhog2B701zvbFiTGg7dm02w28-h8s535BuBaiIiJJPTMgHFKUIJQmCHj0nSVUglSyPPyyXP9gd8dsfsxH1fgdtULg4h58Rla-jH_l5_MVKavyhoE_ima8g3Y5IwxXnRrrb67Hi_npjnkwuSIJUWjY0eNp-fHlqWJYKyA6caltRC0NlMlDymdPegvD1NUkrxZWSot9fWLp_G_p92H3RJbGs3CGA6ggtND2FljHKxBs71i9zZmE2OevZMZisWnoeNbvqpLRg1dDf9iqHLig6EH0Jsfr0LvcQSjTnvY6prlFAVTUVhKTUEII2QOJg4XlB1NXKEohUM3kR4GNmLAEs9HzxaaKZ5LxYQbEYiTiZpoMGN7x1CdzqZ4AobjKwdDPxQYSkbOLgmL-TZp1edcSRfrcLMUbDwvyDLiPMmwo1irINYqiLUK6lDTAvt5q5DV6d_LV7DVHfZ7ce9u8HAG23qX4hbkHKrpIsMLwgWpvMzN4RsmB7Q7 |
| openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Evaluation+of+pulmonary+function+data+using+computer+time-sharing&rft.jtitle=Proceedings+of+the+IEEE&rft.au=Sullivan%2C+S.F.&rft.au=Patterson%2C+R.W.&rft.au=Papper%2C+E.M.&rft.date=1969-01-01&rft.pub=IEEE&rft.issn=0018-9219&rft.volume=57&rft.issue=11&rft.spage=1996&rft.epage=1999&rft_id=info:doi/10.1109%2FPROC.1969.7445&rft.externalDocID=1449375 |
| thumbnail_l | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=0018-9219&client=summon |
| thumbnail_m | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=0018-9219&client=summon |
| thumbnail_s | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=0018-9219&client=summon |