SU‐GG‐T‐94: An Automated Tool for Determining Output Factor for Electron CutOuts
Purpose: To provide streamlined methods for quickly and accurately determining the output factor for irregularly shaped electron cutouts. Measurement on a linear accelerator of output factor for electron cutouts is a time consuming physics task. Existing methods that calculate output factor for shap...
        Saved in:
      
    
          | Published in | Medical Physics Vol. 37; no. 6; p. 3205 | 
|---|---|
| Main Authors | , , , , , | 
| Format | Conference Proceeding Journal Article | 
| Language | English | 
| Published | 
            American Association of Physicists in Medicine
    
        01.06.2010
     | 
| Subjects | |
| Online Access | Get full text | 
| ISSN | 0094-2405 2473-4209  | 
| DOI | 10.1118/1.3468482 | 
Cover
| Abstract | Purpose: To provide streamlined methods for quickly and accurately determining the output factor for irregularly shaped electron cutouts. Measurement on a linear accelerator of output factor for electron cutouts is a time consuming physics task. Existing methods that calculate output factor for shaped apertures are approximations based on cutout length and width, or require a printed version of a cutout shape for either manual measurement or scanning and digitizing. Methods and Materials: An integrated spreadsheet and database provides several options for output factor determination: a measured value or an approximation based on cutout length and width may be used, an image based database containing previously measured cutouts can be searched, or the electron cutout shape contour can be imported electronically from the Philips Pinnacle3 treatment planning system, and the output factor calculated without further user interaction. For the last option, a weighted sector‐integration based algorithm is used that employs polar coordinates and does not require either the calculation of the intersection of equispaced vectors with the block contour or the repeated rotation of the contour. A set of measurements taken for a variety of energies, electron cone sizes, and circular cut out diameters is used to generate a standard output factor table for the sector integration approach. Results: The output factor calculations were tested on a set of cutouts for electron boost treatments. Comparison of measured and calculated output factors are presented. Conclusion: In a busy clinic environment, measurement of output factors for electron cutouts is time burden on physics staff, so automated methods of calculation that involve a minimum of staff time while preserving accuracy have proved valuable in our clinics. | 
    
|---|---|
| AbstractList | Purpose: To provide streamlined methods for quickly and accurately determining the output factor for irregularly shaped electron cutouts. Measurement on a linear accelerator of output factor for electron cutouts is a time consuming physics task. Existing methods that calculate output factor for shaped apertures are approximations based on cutout length and width, or require a printed version of a cutout shape for either manual measurement or scanning and digitizing. Methods and Materials: An integrated spreadsheet and database provides several options for output factor determination: a measured value or an approximation based on cutout length and width may be used, an image based database containing previously measured cutouts can be searched, or the electron cutout shape contour can be imported electronically from the Philips Pinnacle3 treatment planning system, and the output factor calculated without further user interaction. For the last option, a weighted sector‐integration based algorithm is used that employs polar coordinates and does not require either the calculation of the intersection of equispaced vectors with the block contour or the repeated rotation of the contour. A set of measurements taken for a variety of energies, electron cone sizes, and circular cut out diameters is used to generate a standard output factor table for the sector integration approach. Results: The output factor calculations were tested on a set of cutouts for electron boost treatments. Comparison of measured and calculated output factors are presented. Conclusion: In a busy clinic environment, measurement of output factors for electron cutouts is time burden on physics staff, so automated methods of calculation that involve a minimum of staff time while preserving accuracy have proved valuable in our clinics. | 
    
| Author | Mallalieu, L Brewster Jamshidi, A Cao, Y Gill, G Yuen, P Kapur, A  | 
    
| Author_xml | – sequence: 1 givenname: L Brewster surname: Mallalieu fullname: Mallalieu, L Brewster organization: North Shore Long Island Jewish Health System, New Hyde Park, NY – sequence: 2 givenname: G surname: Gill fullname: Gill, G organization: North Shore Long Island Jewish Health System, New Hyde Park, NY – sequence: 3 givenname: P surname: Yuen fullname: Yuen, P organization: North Shore Long Island Jewish Health System, New Hyde Park, NY – sequence: 4 givenname: A surname: Kapur fullname: Kapur, A organization: North Shore Long Island Jewish Health System, New Hyde Park, NY – sequence: 5 givenname: A surname: Jamshidi fullname: Jamshidi, A organization: North Shore Long Island Jewish Health System, New Hyde Park, NY – sequence: 6 givenname: Y surname: Cao fullname: Cao, Y organization: North Shore Long Island Jewish Health System, New Hyde Park, NY  | 
    
| BookMark | eNp9kMtKAzEUhoNUcFpd-AbZKkw9uczNXaltFSoVbN0OaZKRkWlSkgzSnY_gM_okTpludXHOWXwfP5x_iAbGGo3QNYExISS_I2PG05zn9AxFlGcs5hSKAYoACh5TDskFGnr_AQApSyBCb6-bn6_vxaJb624Kfo8nBk_aYHciaIXX1ja4sg4_6KDdrja1ecerNuzbgOdCho4c6azRMjhr8LQNHfWX6LwSjddXpztCm_lsPX2Ml6vF03SyjCXJMhpLSrhiTDHIdVIBCCbkViktiwKSlGiiKqLSAjKlePeNFJmWCdtyQvMKGMvYCN30udJZ752uyr2rd8IdSgLlsZCSlKdCOjfu3c-60Ye_xfL55eTf9r6XdRChtuaf8F88enD5 | 
    
| CODEN | MPHYA6 | 
    
| ContentType | Conference Proceeding Journal Article  | 
    
| Copyright | American Association of Physicists in Medicine 2010 American Association of Physicists in Medicine  | 
    
| Copyright_xml | – notice: American Association of Physicists in Medicine – notice: 2010 American Association of Physicists in Medicine  | 
    
| DBID | AAYXX CITATION  | 
    
| DOI | 10.1118/1.3468482 | 
    
| DatabaseName | CrossRef | 
    
| DatabaseTitle | CrossRef | 
    
| DatabaseTitleList | |
| DeliveryMethod | fulltext_linktorsrc | 
    
| Discipline | Medicine Physics  | 
    
| EISSN | 2473-4209 | 
    
| EndPage | 3205 | 
    
| ExternalDocumentID | 10_1118_1_3468482 MP8482  | 
    
| Genre | abstract | 
    
| GroupedDBID | --- --Z -DZ .GJ 0R~ 1OB 1OC 29M 2WC 33P 36B 3O- 4.4 476 53G 5GY 5RE 5VS AAHHS AANLZ AAQQT AASGY AAXRX AAZKR ABCUV ABEFU ABFTF ABJNI ABLJU ABQWH ABTAH ABXGK ACAHQ ACBEA ACCFJ ACCZN ACGFO ACGFS ACGOF ACPOU ACSMX ACXBN ACXQS ADBBV ADBTR ADKYN ADOZA ADXAS ADZMN AEEZP AEGXH AEIGN AENEX AEQDE AEUYR AFBPY AFFPM AHBTC AIACR AIAGR AIURR AIWBW AJBDE ALMA_UNASSIGNED_HOLDINGS ALUQN AMYDB ASPBG BFHJK C45 CS3 DCZOG DRFUL DRMAN DRSTM DU5 EBD EBS EJD EMB EMOBN F5P G8K HDBZQ HGLYW I-F KBYEO LATKE LEEKS LOXES LUTES LYRES MEWTI O9- OVD P2P P2W PALCI PHY RJQFR RNS ROL SAMSI SUPJJ SV3 TEORI TN5 TWZ USG WOHZO WXSBR XJT ZGI ZVN ZXP ZY4 ZZTAW AAHQN AAIPD AAMMB AAMNL AAYCA ABDPE ADMLS AEFGJ AEYWJ AFWVQ AGHNM AGXDD AGYGG AIDQK AIDYY AITYG ALVPJ AAYXX AIQQE CITATION LH4  | 
    
| ID | FETCH-LOGICAL-c1772-c214d33d308e5f00a3acbddec990561e1df1d6907dd4247ca7ec53b4128f03373 | 
    
| ISSN | 0094-2405 | 
    
| IngestDate | Wed Oct 01 03:17:49 EDT 2025 Wed Aug 20 07:26:35 EDT 2025 Fri Jun 21 00:29:08 EDT 2024  | 
    
| IsPeerReviewed | true | 
    
| IsScholarly | true | 
    
| Issue | 6 | 
    
| Language | English | 
    
| License | http://onlinelibrary.wiley.com/termsAndConditions http://doi.wiley.com/10.1002/tdm_license_1  | 
    
| LinkModel | OpenURL | 
    
| MergedId | FETCHMERGED-LOGICAL-c1772-c214d33d308e5f00a3acbddec990561e1df1d6907dd4247ca7ec53b4128f03373 | 
    
| PageCount | 1 | 
    
| ParticipantIDs | scitation_primary_10_1118_1_3468482 crossref_primary_10_1118_1_3468482 wiley_primary_10_1118_1_3468482_MP8482  | 
    
| ProviderPackageCode | CITATION AAYXX  | 
    
| PublicationCentury | 2000 | 
    
| PublicationDate | June 2010 | 
    
| PublicationDateYYYYMMDD | 2010-06-01 | 
    
| PublicationDate_xml | – month: 06 year: 2010 text: June 2010  | 
    
| PublicationDecade | 2010 | 
    
| PublicationTitle | Medical Physics | 
    
| PublicationYear | 2010 | 
    
| Publisher | American Association of Physicists in Medicine | 
    
| Publisher_xml | – name: American Association of Physicists in Medicine | 
    
| SSID | ssj0006350 | 
    
| Score | 1.9378495 | 
    
| Snippet | Purpose: To provide streamlined methods for quickly and accurately determining the output factor for irregularly shaped electron cutouts. Measurement on a... | 
    
| SourceID | crossref wiley scitation  | 
    
| SourceType | Index Database Publisher  | 
    
| StartPage | 3205 | 
    
| SubjectTerms | Linear accelerators Medical imaging Medical treatment planning  | 
    
| Title | SU‐GG‐T‐94: An Automated Tool for Determining Output Factor for Electron CutOuts | 
    
| URI | http://dx.doi.org/10.1118/1.3468482 https://onlinelibrary.wiley.com/doi/abs/10.1118%2F1.3468482  | 
    
| Volume | 37 | 
    
| hasFullText | 1 | 
    
| inHoldings | 1 | 
    
| isFullTextHit | |
| isPrint | |
| link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV3LjtMwFLWqjnjsYBjE8JIFiM0oQxK7bcKKapjJCAiMNC0aVpFju8u2GiUbVnwC38iXcPyIm4qCgEUc14-o8rGuj6_v9SXkxSJjWV2nk0jLcR6ZKEeRcehETuRcZbGoE-ONXH4cn8_5u6vR1WDwpu9d0tTH8utOv5L_QRVlwNV4yf4DsuGjKEAe-CIFwkh_xXjnUtOds1hDzs5u3ft4zIMhQ1GE7Czkcu6VgtO2WYG3amNTs7LujJBCzkjG6BE-tc26bY7ObGAeW3vqQ-ccnbQNagMrL41SHpy2tZt9TBsI0J71b-Fvzg7RvL60TuYFF7P3Yt1ebxSsXhlhztE7o6lOwObcHNi4g2pty1I-YRFP47wvdN1NL35y9SUoS7vOWz93SHrjvZAcMz7OeIZFeC9lkF5Dsjd9W364DKsxCJVzQ_J_zN8uhe6vQuctTnIL1MNZQWzvVyzhmN0hBxtXTHoRkL9LBnq5T26W3iJin9zwyN8jny_nP759LwokMzw5f02nSxrApQZcCvhoD1zqwKUOXFvbgUs9uAdkfnY6OzmPfNSMSCbYKkUyTbhiTLE406NFHAsmZI1FTIJ3gCzrRC0SZXQiSnFAI8VEyxGrOYjKImZswu6T4XK11A8IHZvdLhpzE6IcTLRWMlVoLFLGxUiKQ_KsG7dq7S5HqdymMquSyg_uIXkeRvRPrV7asf59i6q8MK-Hf_W5R-T2Zno-JsPmutVPwB6b-qmfID8Bq5JmrQ | 
    
| linkProvider | EBSCOhost | 
    
| openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=proceeding&rft.title=Medical+Physics&rft.atitle=SU%E2%80%90GG%E2%80%90T%E2%80%9094%3A+An+Automated+Tool+for+Determining+Output+Factor+for+Electron+CutOuts&rft.au=Mallalieu%2C+L+Brewster&rft.au=Gill%2C+G&rft.au=Yuen%2C+P&rft.au=Kapur%2C+A&rft.date=2010-06-01&rft.issn=0094-2405&rft.eissn=2473-4209&rft.volume=37&rft.issue=6&rft.spage=3205&rft.epage=3205&rft_id=info:doi/10.1118%2F1.3468482 | 
    
| thumbnail_l | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=0094-2405&client=summon | 
    
| thumbnail_m | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=0094-2405&client=summon | 
    
| thumbnail_s | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=0094-2405&client=summon |