Diagnostics of porcelain insulators by partial discharges characteristics

RELEVANCE of the research is in the development of a non-destructive method for diagnosing porcelain insulators of high-voltage electrical equipment based on analysis of the characteristics of partial discharges (PDs). The problem of the final stage of breakdown of both the discharge gap and porcela...

Full description

Saved in:
Bibliographic Details
Published inIzvestiâ vysših učebnyh zavedenij. Problemy ènergetiki Vol. 26; no. 5; pp. 19 - 30
Main Authors Gataullin, A. M., Gavrilenko, A. N., Piskovatskiy, Yu. V., Minkin, A. S.
Format Journal Article
LanguageEnglish
Published Kazan State Power Engineering University 28.10.2024
Subjects
Online AccessGet full text
ISSN1998-9903
2658-5456
2658-5456
DOI10.30724/1998-9903-2024-26-5-19-30

Cover

More Information
Summary:RELEVANCE of the research is in the development of a non-destructive method for diagnosing porcelain insulators of high-voltage electrical equipment based on analysis of the characteristics of partial discharges (PDs). The problem of the final stage of breakdown of both the discharge gap and porcelain insulators recognizing is currently has not solved. THE PURPOSE. Recognition of PDs in solid insulation, study of PDs characteristics in a pre- breakdown situation, recognition of defective insulators based on PDs characteristics analysing. METHODS. The study of PDs characteristics for a defective and functional porcelain insulator were carried out. To study the characteristics of various types of PDs, including in the pre-breakdown situation, a system of surface-needle electrode system was used. RESULTS. The article describes compares the PDs characteristics obtained using standard R-400 device and a digital storage oscilloscope (DSO) using a telescopic antenna. A technique for recognizing the development of the pre-breakdown situation of the surface-needle discharge gap and the porcelain insulator was developed. The technique for recognizing a defective porcelain insulator from the amplitude-phase diagrams (APD) of PDs was developed. The method for assessing the breakdown voltage of porcelain insulators based on the characteristics of partial discharges was developed. CONCLUSION. At the moment of transition to the pre-breakdown stage were observed a sharp increase in the counter-movement of charges of opposite polarity. In the stage immediately before the breakdown, near zero values of the applied voltage of negative polarity, ordered PDs of the same polarity as the applied voltage were recorded in large numbers. These discharges led to an increase in leakage current and were interpreted as initial corona discharges. These discharges were recorded both by a telescopic antenna in a surface-needle system and in porcelain insulators.
ISSN:1998-9903
2658-5456
2658-5456
DOI:10.30724/1998-9903-2024-26-5-19-30