A Method for Evaluating the T2∗-weighting Effect in MRI

Purpose: To propose a method for evaluating the T2*-weighting effect in MRI. Methods: Multiple solutions with different concentrations of a superparamagnetic iron oxide contrast agent were made and their signal intensities on T2*-weighted images were measured. The relationship between iron concentra...

Full description

Saved in:
Bibliographic Details
Published inJapanese Journal of Radiological Technology Vol. 78; no. 4; pp. 357 - 363
Main Authors Saito, Hiroaki, Ohkubo, Masaki, Yagi, Yuta, Kanazawa, Tsutomu
Format Journal Article
LanguageJapanese
Published Kyoto Japanese Society of Radiological Technology 01.01.2022
Japan Science and Technology Agency
Subjects
Online AccessGet full text
ISSN0369-4305
1881-4883
DOI10.6009/jjrt.2022-1189

Cover

More Information
Summary:Purpose: To propose a method for evaluating the T2*-weighting effect in MRI. Methods: Multiple solutions with different concentrations of a superparamagnetic iron oxide contrast agent were made and their signal intensities on T2*-weighted images were measured. The relationship between iron concentration and signal intensity was determined, and we simulated an iron concentration map representing a simplified model of a brain microbleed and converted the pixel values in the map to signal intensity based on the determined relationship, generating a simulated T2*-weighted image. An ‘S-value’ parameter was defined to evaluate the low-intensity regions in the simulated image. S-values were obtained using T2*-weighted sequences acquired with different echo time (TE) values on three MRI scanners (Philips 1.5 T, GE 3.0 T, and Siemens 3.0 T). Another parameter (A-value) defined by the American Society for Testing and Materials (ASTM-F2119) for assessing artifacts was applied to evaluate the weighting effect in the T2*-weighted image of a laboratory-made susceptibility-effect phantom. Results: With all three scanners, the S-values increased as the TE increased, indicating enhancement of the T2*-weighting effect. For every TE, the S-values obtained for the Philips scanner were the largest, followed by those for the GE and Siemens scanners. The results of this comparative evaluation were similar to those obtained using A-values. Conclusion: Comparisons with the established A-value parameter showed our proposed method for the quantitative evaluation of the T2*-weighting effect using S-values to be valid. The proposed method has the advantage that the S-values do not depend on a specific susceptibility-effect phantom.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 14
ISSN:0369-4305
1881-4883
DOI:10.6009/jjrt.2022-1189