A Robust Auto-Planning Algorithm Based Artificial Intelligence for Pencil Beam Scanning Proton Therapy
While proton therapy has the theoretical potential for high precision, in practice, it still requires addressing uncertainties introduced by factors. However, conventional planning systems struggle to fast the optimizing plans while accounting for these numerous sources of uncertainty. We developed...
        Saved in:
      
    
          | Published in | International journal of radiation oncology, biology, physics Vol. 120; no. 2; pp. e159 - e160 | 
|---|---|
| Main Authors | , , , , , , , , , , , | 
| Format | Journal Article | 
| Language | English | 
| Published | 
            Elsevier Inc
    
        01.10.2024
     | 
| Online Access | Get full text | 
| ISSN | 0360-3016 | 
| DOI | 10.1016/j.ijrobp.2024.07.361 | 
Cover
| Abstract | While proton therapy has the theoretical potential for high precision, in practice, it still requires addressing uncertainties introduced by factors. However, conventional planning systems struggle to fast the optimizing plans while accounting for these numerous sources of uncertainty. We developed a robust auto-planning algorithm based on artificial intelligence to overcome the challenges.
The robust automatic planning algorithm has two modules. The first is a GPU-accelerated neural network dose influence matrix (NN-Dij) engine, which resulted that the Dij matrix calculation being ultra-speedy in specific gantry and uncertainty settings. The second is an interface for reference DVHs as the optimization objectives for robust auto-planning. It allows input of reference plans or results of dose predictions. When applying a weight matrix to the Dij matrix, each ROI has numbers (equal to uncertainty number) of DVHs, then calculate the punishment function (target/OAR DVH should be consistent/lower to reference), and find the worst DVH of each ROI for optimization. The robust auto-planning module ensures that all DVHs (in different uncertainties) in a plan are consistent/lower to reference DVHs. We set nine uncertainties and verified the algorithm on the lungs and head. By inputting the plan from the treatment planning system as a reference plan and the plan optimization was automatically completed.
Evaluation used the difference between DVHs. For the target and OARs, the difference was 0.32 ± 0.26Gy and 0.06 ± 0.315Gy for the lung site (a detail in Table 1) and the mean value for the head site was -0.16 ± 0.19Gy and -2.59 ± 3.06Gy. The target D95 difference for lung head cases was 0.31 ± 0.25Gy and 0.13 ± 0.47Gy. The time cost of NN-Dij and robust auto-plan was within 2 minutes on RTX3090-server.
The robust automatic planning algorithm has a significant advantage in PBS planning, for automation, efficiency, quality and robustness. This not only enhances the quality and safety of clinical treatments but also promotes the modernization and efficiency of the entire proton radiotherapy process. | 
    
|---|---|
| AbstractList | While proton therapy has the theoretical potential for high precision, in practice, it still requires addressing uncertainties introduced by factors. However, conventional planning systems struggle to fast the optimizing plans while accounting for these numerous sources of uncertainty. We developed a robust auto-planning algorithm based on artificial intelligence to overcome the challenges.
The robust automatic planning algorithm has two modules. The first is a GPU-accelerated neural network dose influence matrix (NN-Dij) engine, which resulted that the Dij matrix calculation being ultra-speedy in specific gantry and uncertainty settings. The second is an interface for reference DVHs as the optimization objectives for robust auto-planning. It allows input of reference plans or results of dose predictions. When applying a weight matrix to the Dij matrix, each ROI has numbers (equal to uncertainty number) of DVHs, then calculate the punishment function (target/OAR DVH should be consistent/lower to reference), and find the worst DVH of each ROI for optimization. The robust auto-planning module ensures that all DVHs (in different uncertainties) in a plan are consistent/lower to reference DVHs. We set nine uncertainties and verified the algorithm on the lungs and head. By inputting the plan from the treatment planning system as a reference plan and the plan optimization was automatically completed.
Evaluation used the difference between DVHs. For the target and OARs, the difference was 0.32 ± 0.26Gy and 0.06 ± 0.315Gy for the lung site (a detail in Table 1) and the mean value for the head site was -0.16 ± 0.19Gy and -2.59 ± 3.06Gy. The target D95 difference for lung head cases was 0.31 ± 0.25Gy and 0.13 ± 0.47Gy. The time cost of NN-Dij and robust auto-plan was within 2 minutes on RTX3090-server.
The robust automatic planning algorithm has a significant advantage in PBS planning, for automation, efficiency, quality and robustness. This not only enhances the quality and safety of clinical treatments but also promotes the modernization and efficiency of the entire proton radiotherapy process. | 
    
| Author | Fang, C. Xu, S. Shang, X. Zhou, Q. Le, X. Li, Z.R. Zou, Y. Liu, Y. Wang, Z. Li, N. Zhang, G. Zhao, W.  | 
    
| Author_xml | – sequence: 1 givenname: Y. surname: Liu fullname: Liu, Y. organization: National Cancer Center/ National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China – sequence: 2 givenname: X. surname: Shang fullname: Shang, X. organization: National Cancer Center/ National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China – sequence: 3 givenname: Z.R. surname: Li fullname: Li, Z.R. organization: Department of Research Algorithms, Manteia Technologies Co., Ltd, Xiamen, Fujian, China – sequence: 4 givenname: N. surname: Li fullname: Li, N. organization: Department of Oncology, Yizhou Pronton Therapy Center, Zhuozhou, Hebei, China – sequence: 5 givenname: Z. surname: Wang fullname: Wang, Z. organization: Department of Oncology, Yizhou Pronton Therapy Center, Zhuozhou, Hebei, China – sequence: 6 givenname: C. surname: Fang fullname: Fang, C. organization: Department of Oncology, Yizhou Pronton Therapy Center, Zhuozhou, Hebei, China – sequence: 7 givenname: Y. surname: Zou fullname: Zou, Y. organization: Department of Oncology, Yizhou Pronton Therapy Center, Zhuozhou, Hebei, China – sequence: 8 givenname: W. surname: Zhao fullname: Zhao, W. organization: Beihang Hangzhou Innovation Institute, Hangzhou, Zhejiang, China – sequence: 9 givenname: X. surname: Le fullname: Le, X. organization: School of Physics, Beihang University, Beijing, China – sequence: 10 givenname: Q. surname: Zhou fullname: Zhou, Q. organization: Department of Research Algorithms, Manteia Technologies Co., Ltd, Xiamen, Fujian, China – sequence: 11 givenname: G. surname: Zhang fullname: Zhang, G. organization: School of Physics, Beihang University, Beijing, China – sequence: 12 givenname: S. surname: Xu fullname: Xu, S. organization: National Cancer Center/ National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China  | 
    
| BookMark | eNqFkMtuwjAQRb2gUoH2D7rwDyS14zylqlJAfSAhFbV0bTnOGJwaG9mhEn_fIFh1w2pmce_RzJmgkXUWEHqgJKaE5o9drDvvmn2ckCSNSRGznI7QmLCcRGwI3KJJCB0hhNIiHSNV40_XHEKP60PvopUR1mq7wbXZOK_77Q7PRIAW177XSkstDF7YHozRG7ASsHIer4ZNGzwDscNf8gJYedc7i9db8GJ_vEM3SpgA95c5Rd-vL-v5e7T8eFvM62UkacZo1FCWEqhUkzBoGVWEiYowVmSZYCmUtIRE0LZs0zRheQUJKxtVkiopGGSSDPEpSs9c6V0IHhTfe70T_sgp4Sc_vONnP_zkh5OCD36G2vO5BsNtvxo8D1Kf_mu1B9nz1ulrgKd_AGm01VKYHzher_8BpBOIlw | 
    
| ContentType | Journal Article | 
    
| Copyright | 2024 | 
    
| Copyright_xml | – notice: 2024 | 
    
| DBID | AAYXX CITATION  | 
    
| DOI | 10.1016/j.ijrobp.2024.07.361 | 
    
| DatabaseName | CrossRef | 
    
| DatabaseTitle | CrossRef | 
    
| DatabaseTitleList | |
| DeliveryMethod | fulltext_linktorsrc | 
    
| Discipline | Medicine | 
    
| EndPage | e160 | 
    
| ExternalDocumentID | 10_1016_j_ijrobp_2024_07_361 S0360301624011234  | 
    
| GroupedDBID | --- --K .1- .FO 0R~ 1B1 1P~ 1RT 1~5 4.4 457 4G. 53G 5RE 7-5 AAEDT AAEDW AALRI AAWTL AAXUO ABJNI ABLJU ABNEU ABOCM ABUDA ACGFS ACIUM ADBBV AENEX AEVXI AFJKZ AFRHN AFTJW AHHHB AITUG AJUYK AKRWK ALMA_UNASSIGNED_HOLDINGS AMRAJ BELOY DU5 EBS EFKBS F5P FDB GBLVA HED HMO IHE J1W KOM LX3 M41 MO0 O9- OC~ OO- RNS ROL RPZ SDG SEL SES SSZ UV1 XH2 Z5R ~S- AFCTW EFJIC RIG SEW .55 .GJ 29J 5VS AAQFI AAQQT AAQXK AAYWO AAYXX ABEFU ABWVN ACRPL ACVFH ADCNI ADMUD ADNMO ADVLN AEUPX AFFNX AFPUW AGQPQ AGRDE AIGII AKBMS AKYEP ASPBG AVWKF AZFZN CITATION EJD FEDTE FGOYB FIRID G-2 HMK HVGLF HX~ HZ~ NQ- R2- SAE UDS X7M XPP ZGI  | 
    
| ID | FETCH-LOGICAL-c1531-b1340e9fb23ed31f03a9033755a34e818e2a1d8d442369e238bf809273e5c0f03 | 
    
| ISSN | 0360-3016 | 
    
| IngestDate | Wed Oct 01 01:56:00 EDT 2025 Sat Nov 02 16:00:44 EDT 2024 Tue Oct 14 19:28:52 EDT 2025  | 
    
| IsPeerReviewed | true | 
    
| IsScholarly | true | 
    
| Issue | 2 | 
    
| Language | English | 
    
| LinkModel | OpenURL | 
    
| MergedId | FETCHMERGED-LOGICAL-c1531-b1340e9fb23ed31f03a9033755a34e818e2a1d8d442369e238bf809273e5c0f03 | 
    
| ParticipantIDs | crossref_primary_10_1016_j_ijrobp_2024_07_361 elsevier_sciencedirect_doi_10_1016_j_ijrobp_2024_07_361 elsevier_clinicalkey_doi_10_1016_j_ijrobp_2024_07_361  | 
    
| ProviderPackageCode | CITATION AAYXX  | 
    
| PublicationCentury | 2000 | 
    
| PublicationDate | 2024-10-01 2024-10-00  | 
    
| PublicationDateYYYYMMDD | 2024-10-01 | 
    
| PublicationDate_xml | – month: 10 year: 2024 text: 2024-10-01 day: 01  | 
    
| PublicationDecade | 2020 | 
    
| PublicationTitle | International journal of radiation oncology, biology, physics | 
    
| PublicationYear | 2024 | 
    
| Publisher | Elsevier Inc | 
    
| Publisher_xml | – name: Elsevier Inc | 
    
| SSID | ssj0001174 | 
    
| Score | 2.4623117 | 
    
| Snippet | While proton therapy has the theoretical potential for high precision, in practice, it still requires addressing uncertainties introduced by factors. However,... | 
    
| SourceID | crossref elsevier  | 
    
| SourceType | Index Database Publisher  | 
    
| StartPage | e159 | 
    
| Title | A Robust Auto-Planning Algorithm Based Artificial Intelligence for Pencil Beam Scanning Proton Therapy | 
    
| URI | https://www.clinicalkey.com/#!/content/1-s2.0-S0360301624011234 https://dx.doi.org/10.1016/j.ijrobp.2024.07.361  | 
    
| Volume | 120 | 
    
| hasFullText | 1 | 
    
| inHoldings | 1 | 
    
| isFullTextHit | |
| isPrint | |
| journalDatabaseRights | – providerCode: PRVESC databaseName: Baden-Württemberg Complete Freedom Collection (Elsevier) issn: 0360-3016 databaseCode: GBLVA dateStart: 20110101 customDbUrl: isFulltext: true dateEnd: 99991231 titleUrlDefault: https://www.sciencedirect.com omitProxy: true ssIdentifier: ssj0001174 providerName: Elsevier – providerCode: PRVLSH databaseName: Elsevier Journals issn: 0360-3016 databaseCode: AKRWK dateStart: 19761001 customDbUrl: isFulltext: true mediaType: online dateEnd: 99991231 omitProxy: true ssIdentifier: ssj0001174 providerName: Library Specific Holdings  | 
    
| link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV1Lb5wwELZWG6nqpepTTfqQD72tQMaPAEdStUqbJoqijbo3BMZud5Us1RYu_S_9rx2vjXEeappeEFjYAubzzHiY-YzQOy1lLniSRSkTZoGSVVGecRGB8aMwv3QmtYl3HJ_sH57zzwuxmEx-B1lLfVfH8tetdSX_I1VoA7maKtl7SNYPCg1wDvKFI0gYjv8k48IkRvc_u1nRd2007D80Ky6-tbDm_345OwAb1ZgA_NIRRXwKGThNhuEpnC0vZgequoR57gY43bSGbWMeMA6sxoz3MYAY0E5sDMeB9T7X0lfA1GMxjA2heA_-y7Lfav_Yh3iGyPUiHu_Z_jqJz661nMRhrIJyn_U21miB1ie2utLrX0oCoNFAm6rEsYUrd2m3Hrih9W0AYhUvV5u2NiSklBtGVmZp3q-SbF8zfj4lcch2W5V2lNKMUpK0ZGZxvUPBaJAp2imOzr4eeVOfOJrv4bWG2sxtAuHNp7nd9wn8mflj9MgtRHBhUfUETdT6KXpw7FItniFdYAsufAVc2IMLb8GFR3DhEFwYwIUtuLABFx7AhS24sAPXc3T-8cP8_WHkNuWIJBjHJKoTxonKdU2ZaliiCatywlgqRMW4AvdP0SppsoaDn76fK_AIa52RHLxkJSSB21-g6bpdq5cIg_bQ0CHRlDRcK_NHX0mSyqwSoCLqfBdFw-cqf1julfJvYtpFYvim5VBXDJawBJjc0S_1_Zzfaf3JO3vu3fMJX6GH47R4jabdpldvwKnt6rcOWn8AOk6iIg | 
    
| linkProvider | Library Specific Holdings | 
    
| openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=A+Robust+Auto-Planning+Algorithm+Based+Artificial+Intelligence+for+Pencil+Beam+Scanning+Proton+Therapy&rft.jtitle=International+journal+of+radiation+oncology%2C+biology%2C+physics&rft.au=Liu%2C+Y.&rft.au=Shang%2C+X.&rft.au=Li%2C+Z.R.&rft.au=Li%2C+N.&rft.date=2024-10-01&rft.issn=0360-3016&rft.volume=120&rft.issue=2&rft.spage=e159&rft.epage=e160&rft_id=info:doi/10.1016%2Fj.ijrobp.2024.07.361&rft.externalDBID=n%2Fa&rft.externalDocID=10_1016_j_ijrobp_2024_07_361 | 
    
| thumbnail_l | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=0360-3016&client=summon | 
    
| thumbnail_m | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=0360-3016&client=summon | 
    
| thumbnail_s | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=0360-3016&client=summon |