Improving resilience of islanding protection - implementation of a Q-f droop for inverter-based generation
As the prevalence of distributed generation (DG) continues to increase in the GB network, anti-islanding protection has been the subject of industry focus, with work done to alter the existing Rate of Change of Frequency (ROCOF) settings. However, there are still concerns regarding the resilience an...
Saved in:
| Published in | 19th International Conference on AC and DC Power Transmission (ACDC 2023) Vol. 2023; pp. 122 - 130 |
|---|---|
| Main Authors | , , , , , |
| Format | Conference Proceeding |
| Language | English |
| Published |
The Institution of Engineering and Technology
2023
|
| Online Access | Get full text |
| DOI | 10.1049/icp.2023.1318 |
Cover
| Abstract | As the prevalence of distributed generation (DG) continues to increase in the GB network, anti-islanding protection has been the subject of industry focus, with work done to alter the existing Rate of Change of Frequency (ROCOF) settings. However, there are still concerns regarding the resilience and security of this method based upon non-detection zones (NDZ), and the potential of system-wide events and network faults leading to nuisance tripping. This paper provides a review of the theory and literature, exploring the issues with power system islanding and the current anti-islanding protection methods. A novel protection method, based on a reactive power - frequency (Q-f) droop, is developed and implemented into a Simulink inverter-connected DG model, to test under various distribution network scenarios including islanding and system-wide frequency excursions. This new method was compared to the existing ROCOF method and showed improved performance in all network scenarios studies. The Q-f droop method had no NDZ and was developed to be customisable for a range of network regulation requirements. Finally, aspects of the method such as multi-DG operation, financial and practical implications have been explored. |
|---|---|
| AbstractList | As the prevalence of distributed generation (DG) continues to increase in the GB network, anti-islanding protection has been the subject of industry focus, with work done to alter the existing Rate of Change of Frequency (ROCOF) settings. However, there are still concerns regarding the resilience and security of this method based upon non-detection zones (NDZ), and the potential of system-wide events and network faults leading to nuisance tripping. This paper provides a review of the theory and literature, exploring the issues with power system islanding and the current anti-islanding protection methods. A novel protection method, based on a reactive power - frequency (Q-f) droop, is developed and implemented into a Simulink inverter-connected DG model, to test under various distribution network scenarios including islanding and system-wide frequency excursions. This new method was compared to the existing ROCOF method and showed improved performance in all network scenarios studies. The Q-f droop method had no NDZ and was developed to be customisable for a range of network regulation requirements. Finally, aspects of the method such as multi-DG operation, financial and practical implications have been explored. |
| Author | Kent, M. A. Williams, S. J. Hendry, R. Dysko, A. Peebles, A. S. Kemp-Garcia, R. C. |
| Author_xml | – sequence: 1 givenname: M. A. surname: Kent fullname: Kent, M. A. organization: Electronic & Electrical Engineering, University of Strathclyde, Royal College Building, 204 George St, Glasgow, Scotland – sequence: 2 givenname: A. S. surname: Peebles fullname: Peebles, A. S. organization: Electronic & Electrical Engineering, University of Strathclyde, Royal College Building, 204 George St, Glasgow, Scotland – sequence: 3 givenname: S. J. surname: Williams fullname: Williams, S. J. organization: Electronic & Electrical Engineering, University of Strathclyde, Royal College Building, 204 George St, Glasgow, Scotland – sequence: 4 givenname: R. surname: Hendry fullname: Hendry, R. organization: Electronic & Electrical Engineering, University of Strathclyde, Royal College Building, 204 George St, Glasgow, Scotland – sequence: 5 givenname: R. C. surname: Kemp-Garcia fullname: Kemp-Garcia, R. C. organization: Electronic & Electrical Engineering, University of Strathclyde, Royal College Building, 204 George St, Glasgow, Scotland – sequence: 6 givenname: A. surname: Dysko fullname: Dysko, A. organization: Electronic & Electrical Engineering, University of Strathclyde, Royal College Building, 204 George St, Glasgow, Scotland |
| BookMark | eNotkEtLxDAUhSMo6IyzdOcif6A1t7fpYymDj4EBEXQ93CY3Q6RNSloG_PfW0dWB73ycxVmJyxADC3EHKgdVtg_ejHmhCswBobkQK2iw1dhUGq7FZpp8pzSgVrqEG_G1G8YUTz4cZeLJ956DYRmd9FNPwf7ypZ_ZzD4GmUk_jD0PHGY6g0Uk-Z45aVOMo3QxSR9OnGZOWUcTW3nkwOks34orR_3Em_9ci8_np4_ta7Z_e9ltH_eZgaKds8pRR20Bne5UoTS6qgRtoIIagZBUY12JtuaKq5p0QwbRkMXGlI7bzmlci_u_Xc_MhzH5gdL3ARTg8gDiD0GaWTk |
| ContentType | Conference Proceeding |
| DBID | 6IE 6IF 6IG 6IH 6IL 6IM 6IN CBEJK RIE RIL RIO |
| DOI | 10.1049/icp.2023.1318 |
| DatabaseName | IEEE Electronic Library (IEL) Conference Proceedings IEEE Proceedings Order Plans (POP All) 2005-Present IEEE Proceedings Order Plan (POP) 2005-present IEEE Proceedings Order Plan (POP) 1998-present by volume IEEE Xplore POP ALL IEEE Proceedings Order Plan (POP) 2005-present by volume IEEE Xplore POP ALL IEEE Xplore All Conference Proceedings IEEE Electronic Library (IEL) IEEE Proceedings Order Plans (POP All) 1998-Present IEEE Proceedings Order Plans (POP) 1998-present |
| DatabaseTitleList | |
| Database_xml | – sequence: 1 dbid: RIE name: IEEE Electronic Library (IEL) url: https://proxy.k.utb.cz/login?url=https://ieeexplore.ieee.org/ sourceTypes: Publisher |
| DeliveryMethod | fulltext_linktorsrc |
| EISBN | 1839538651 9781839538650 |
| EndPage | 130 |
| ExternalDocumentID | 10136513 |
| Genre | orig-research |
| GroupedDBID | 6IE 6IF 6IG 6IH 6IL 6IM 6IN AAWTH ALMA_UNASSIGNED_HOLDINGS BEFXN BFFAM BGNUA BKEBE BPEOZ CBEJK OCL RIE RIL RIO |
| ID | FETCH-LOGICAL-c129t-6faba921b5b02053f6415c161731a3a08df43d7e6e67a58ac33cad38c4fe9bf53 |
| IEDL.DBID | RIE |
| IngestDate | Wed Aug 27 02:13:45 EDT 2025 |
| IsPeerReviewed | false |
| IsScholarly | false |
| Language | English |
| LinkModel | DirectLink |
| MergedId | FETCHMERGED-LOGICAL-c129t-6faba921b5b02053f6415c161731a3a08df43d7e6e67a58ac33cad38c4fe9bf53 |
| PageCount | 9 |
| ParticipantIDs | ieee_primary_10136513 |
| PublicationCentury | 2000 |
| PublicationDate | 2023-00-00 |
| PublicationDateYYYYMMDD | 2023-01-01 |
| PublicationDate_xml | – year: 2023 text: 2023-00-00 |
| PublicationDecade | 2020 |
| PublicationTitle | 19th International Conference on AC and DC Power Transmission (ACDC 2023) |
| PublicationTitleAbbrev | ACDC 2023 |
| PublicationYear | 2023 |
| Publisher | The Institution of Engineering and Technology |
| Publisher_xml | – name: The Institution of Engineering and Technology |
| SSID | ssib051350541 |
| Score | 1.8208239 |
| Snippet | As the prevalence of distributed generation (DG) continues to increase in the GB network, anti-islanding protection has been the subject of industry focus,... |
| SourceID | ieee |
| SourceType | Publisher |
| StartPage | 122 |
| Title | Improving resilience of islanding protection - implementation of a Q-f droop for inverter-based generation |
| URI | https://ieeexplore.ieee.org/document/10136513 |
| Volume | 2023 |
| hasFullText | 1 |
| inHoldings | 1 |
| isFullTextHit | |
| isPrint | |
| link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwjV1LS8NAEF60J08qVnyzB68bm2yySc9iKR6KgoXeyj5mJFrTUtNLf72zm6SKIHgLw8KGnZ1830zmwditwxyJF4Oguxv70I0VhpivQI2Ig4L8FhcSZCdqPE0fZ9msLVYPtTAAEJLPIPKP4V--W9qND5WRhfukLD-jdj8vVFOs1V0eEhOYp3HbR5OI711pfUPKREax9DM9fkxPCeAxOmSTbtsmZ-Q92tQmsttfHRn__V5HrP9dp8efdgh0zPagOmFvuzgBJ1e6XATb5Uvk5eeiqWHhbXMGUgkXvPzoUsiDgBZq_iyQO-LUK06clpeVH9oMa-Ehz_HX0KnaL-6z6ejh5X4s2okKwhKu10KhNnqYxCYzRBMziYrw23oXR8Za6kHhMJUuBwUq11mhrZRWO1nYFGFoMJOnrFctKzhjPMkt2brSUGhyMe2gyBNMwCj6fhAYxvac9f1BzVdN04x5d0YXf8gv2YHXVRPduGK9er2Ba8L72twEPX8BSOSszQ |
| linkProvider | IEEE |
| linkToHtml | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwjV1LS8NAEF6kHvSkYkWtjz143dhkH0nPYqlai0ILvZV9SrSmpaYXf72zm6SKIHgLm4WEnd1830xmvkHoyrjUAS-2BPZu7EM3mihgvsRJ51w3A7_FhATZkRhM2P2UT-ti9VALY60NyWc28pfhX75Z6LUPlcEJ90lZvkftNmeM8apcq9k-cAPgnMW1kiZQ3-tce0nKhEYx9V09fvRPCfDR30Oj5sFV1shbtC5VpD9_aTL--832Ufu7Ug8_bTDoAG3Z4hC9biIFGJzpfB5OL144nH_MqyoWXMszgFEwwfl7k0QeBmCixM_EYQOseomB1eK88G2b7Yp40DP4JWhV-8ltNOnfjm8GpO6pQDQge0mEk0r2klhxBUSRUycAwbV3cmgsqexmxjFqUiusSCXPpKZUS0MzzZztKcfpEWoVi8IeI5ykGk67kDaT4GTqbpYmLrFKwBcE4DDWJ6jtF2q2rGQzZs0anf4xfol2BuPH4Wx4N3rooF1vtyrWcYZa5WptzwH9S3URbP4FgiqwGg |
| openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Abook&rft.genre=proceeding&rft.title=19th+International+Conference+on+AC+and+DC+Power+Transmission+%28ACDC+2023%29&rft.atitle=Improving+resilience+of+islanding+protection+-+implementation+of+a+Q-f+droop+for+inverter-based+generation&rft.au=Kent%2C+M.+A.&rft.au=Peebles%2C+A.+S.&rft.au=Williams%2C+S.+J.&rft.au=Hendry%2C+R.&rft.date=2023-01-01&rft.pub=The+Institution+of+Engineering+and+Technology&rft.volume=2023&rft.spage=122&rft.epage=130&rft_id=info:doi/10.1049%2Ficp.2023.1318&rft.externalDocID=10136513 |