Validation of Hematology Rapid Reporting System for Complete Blood Cell Count with Differential
Background: Complete blood cell count (CBC) test, peripheral blood smears (PBS), and automatic hematology analyzers are used to screen pa- tients with high-risk hematology malignancies. In this study, the workflow of urgent and routine samples and methods to improve the detection rate of blasts were...
Saved in:
| Published in | Laboratory Medicine Online Vol. 12; no. 1; pp. 33 - 39 |
|---|---|
| Main Authors | , , , |
| Format | Journal Article |
| Language | English |
| Published |
대한진단검사의학회
01.01.2022
|
| Subjects | |
| Online Access | Get full text |
| ISSN | 2093-6338 2093-6338 |
| DOI | 10.47429/lmo.2022.12.1.33 |
Cover
| Abstract | Background: Complete blood cell count (CBC) test, peripheral blood smears (PBS), and automatic hematology analyzers are used to screen pa- tients with high-risk hematology malignancies. In this study, the workflow of urgent and routine samples and methods to improve the detection rate of blasts were evaluated. The purpose of this study was to validate the hematology rapid reporting system (HRS) for CBC and establish a strategy for the effective use of an automated hematology analyzer in clinical laboratories.
Methods: The flag performances of UniCel DxH 800 (Beckman Coulter, USA) and XE-2100 (Sysmex, Japan) systems used for blood tests were analyzed for urgent and routine samples. The results were compared with PBS results. Each test method’s sensitivity and specificity were deter- mined to identify the most efficient blast detection method. In addition, receiver operating characteristic (ROC) curves of various parameters such as CBC and age were analyzed.
Results: The sensitivity and specificity of HRS were 66.80% and 99.85%, respectively, with urgent flags (four flags) and 92.95% and 98.49%, respectively, with routine flags (15 flags). The sensitivity of HRS for routine samples was significantly different from that for urgent samples (66.80% vs. 92.95%; < 0.0001), but no significant difference was observed in the specificity for HRS between routine and urgent samples (99.85% vs. 98.49%; = 1.00).
Conclusions: HRS using flags and blast history can be effectively used in clinical laboratories. HRS can be used as an effective reporting work- flow for differential CBC in clinical laboratories. KCI Citation Count: 0 |
|---|---|
| AbstractList | Background: Complete blood cell count (CBC) test, peripheral blood smears (PBS), and automatic hematology analyzers are used to screen pa- tients with high-risk hematology malignancies. In this study, the workflow of urgent and routine samples and methods to improve the detection rate of blasts were evaluated. The purpose of this study was to validate the hematology rapid reporting system (HRS) for CBC and establish a strategy for the effective use of an automated hematology analyzer in clinical laboratories.
Methods: The flag performances of UniCel DxH 800 (Beckman Coulter, USA) and XE-2100 (Sysmex, Japan) systems used for blood tests were analyzed for urgent and routine samples. The results were compared with PBS results. Each test method’s sensitivity and specificity were deter- mined to identify the most efficient blast detection method. In addition, receiver operating characteristic (ROC) curves of various parameters such as CBC and age were analyzed.
Results: The sensitivity and specificity of HRS were 66.80% and 99.85%, respectively, with urgent flags (four flags) and 92.95% and 98.49%, respectively, with routine flags (15 flags). The sensitivity of HRS for routine samples was significantly different from that for urgent samples (66.80% vs. 92.95%; < 0.0001), but no significant difference was observed in the specificity for HRS between routine and urgent samples (99.85% vs. 98.49%; = 1.00).
Conclusions: HRS using flags and blast history can be effectively used in clinical laboratories. HRS can be used as an effective reporting work- flow for differential CBC in clinical laboratories. KCI Citation Count: 0 |
| Author | Lee, Jungmin Kim, Jeeyong Yoon, Soo-Young Park, Ji Young |
| Author_xml | – sequence: 1 givenname: Jungmin surname: Lee fullname: Lee, Jungmin organization: Department of Laboratory Medicine, Korea University Guro Hospital, Korea University College of Medicine, Seoul, Korea – sequence: 2 givenname: Soo-Young surname: Yoon fullname: Yoon, Soo-Young organization: Department of Laboratory Medicine, Korea University Guro Hospital, Korea University College of Medicine, Seoul, Korea – sequence: 3 givenname: Ji Young surname: Park fullname: Park, Ji Young organization: Department of Laboratory Medicine, Korea University Guro Hospital, Korea University College of Medicine, Seoul, Korea – sequence: 4 givenname: Jeeyong orcidid: 0000-0002-0426-2572 surname: Kim fullname: Kim, Jeeyong organization: Department of Laboratory Medicine, Korea University Guro Hospital, Korea University College of Medicine, Seoul, Korea |
| BackLink | https://www.kci.go.kr/kciportal/ci/sereArticleSearch/ciSereArtiView.kci?sereArticleSearchBean.artiId=ART002794614$$DAccess content in National Research Foundation of Korea (NRF) |
| BookMark | eNqNUE1LAzEUDFLBWvsDvOXqoWs-9qN7rPWjhYJQq9eQZF9qaHazZLfI_ntj68GjMDDD481j3lyjUeMbQOiWkiQtUlbeu9onjDCW0IiE8ws0ZqTks5zz-eiPvkLTrrOKkDknRVqWYyQ-pLOV7K1vsDd4BbXsvfP7AW9layu8hdaH3jZ7_DZ0PdTY-ICXvm4d9IAfnPcVXoJzcXZsevxl-0_8aI2BAE1vpbtBl0a6Dqa_PEHvz0-75Wq2eX1ZLxebmaY0hisrCTkomUMls4wVjKVag1ZglCwZz0xWMEpJruYpUUQXVaaUYVyDLDLKopqgu_PdJhhx0FZ4aU-89-IQxGK7W4uyJCmNr08QO-8em1YOX9I50QZbyzAISsSpUREbFT-NChohOI8mejbp4LsugPmH5xswF3y_ |
| Cites_doi | 10.1532/LH96.05019 10.1111/ijlh.12651 10.5858/2006-130-596-LPATRO 10.1111/ijlh.12225 10.1309/AJCPDLR4KGKAFW4W 10.3343/lmo.2013.3.3.131 10.1056/NEJMra043442 10.11406/rinketsu.61.564 |
| ContentType | Journal Article |
| DBID | AAYXX CITATION ADTOC UNPAY ACYCR |
| DOI | 10.47429/lmo.2022.12.1.33 |
| DatabaseName | CrossRef Unpaywall for CDI: Periodical Content Unpaywall Korean Citation Index |
| DatabaseTitle | CrossRef |
| DatabaseTitleList | |
| Database_xml | – sequence: 1 dbid: UNPAY name: Unpaywall url: https://proxy.k.utb.cz/login?url=https://unpaywall.org/ sourceTypes: Open Access Repository |
| DeliveryMethod | fulltext_linktorsrc |
| EISSN | 2093-6338 |
| EndPage | 39 |
| ExternalDocumentID | oai_kci_go_kr_ARTI_9904108 10.47429/lmo.2022.12.1.33 10_47429_lmo_2022_12_1_33 |
| GroupedDBID | 5-W 8JR 8XY AAYXX ACYCR ALMA_UNASSIGNED_HOLDINGS CITATION EF. ADTOC UNPAY |
| ID | FETCH-LOGICAL-c1193-9dae6eba6eda5527224ccecbefba9235f5721106b840b0c7d5bbf23cea7512f23 |
| IEDL.DBID | UNPAY |
| ISSN | 2093-6338 |
| IngestDate | Tue Nov 21 21:24:05 EST 2023 Tue Aug 19 22:46:56 EDT 2025 Tue Jul 01 04:32:40 EDT 2025 |
| IsDoiOpenAccess | true |
| IsOpenAccess | true |
| IsPeerReviewed | true |
| IsScholarly | true |
| Issue | 1 |
| Language | English |
| License | cc-by-nc |
| LinkModel | DirectLink |
| MergedId | FETCHMERGED-LOGICAL-c1193-9dae6eba6eda5527224ccecbefba9235f5721106b840b0c7d5bbf23cea7512f23 |
| Notes | https://doi.org/10.47429/lmo.2022.12.1.33 |
| ORCID | 0000-0002-0426-2572 |
| OpenAccessLink | https://proxy.k.utb.cz/login?url=https://labmedonline.org/journal/download_pdf.php?doi=10.47429/lmo.2022.12.1.33 |
| PageCount | 7 |
| ParticipantIDs | nrf_kci_oai_kci_go_kr_ARTI_9904108 unpaywall_primary_10_47429_lmo_2022_12_1_33 crossref_primary_10_47429_lmo_2022_12_1_33 |
| ProviderPackageCode | CITATION AAYXX |
| PublicationCentury | 2000 |
| PublicationDate | 2022-01-01 2022-01 |
| PublicationDateYYYYMMDD | 2022-01-01 |
| PublicationDate_xml | – month: 01 year: 2022 text: 2022-01-01 day: 01 |
| PublicationDecade | 2020 |
| PublicationTitle | Laboratory Medicine Online |
| PublicationYear | 2022 |
| Publisher | 대한진단검사의학회 |
| Publisher_xml | – name: 대한진단검사의학회 |
| References | ref8 ref7 ref9 ref4 ref3 ref6 ref5 ref2 ref1 |
| References_xml | – ident: ref3 doi: 10.1532/LH96.05019 – ident: ref6 doi: 10.1111/ijlh.12651 – ident: ref8 – ident: ref9 doi: 10.5858/2006-130-596-LPATRO – ident: ref7 doi: 10.1111/ijlh.12225 – ident: ref2 doi: 10.1309/AJCPDLR4KGKAFW4W – ident: ref1 doi: 10.3343/lmo.2013.3.3.131 – ident: ref4 doi: 10.1056/NEJMra043442 – ident: ref5 doi: 10.11406/rinketsu.61.564 |
| SSID | ssib008307499 |
| Score | 2.1708891 |
| Snippet | Background: Complete blood cell count (CBC) test, peripheral blood smears (PBS), and automatic hematology analyzers are used to screen pa- tients with... |
| SourceID | nrf unpaywall crossref |
| SourceType | Open Website Open Access Repository Index Database |
| StartPage | 33 |
| SubjectTerms | 임상병리학 |
| Title | Validation of Hematology Rapid Reporting System for Complete Blood Cell Count with Differential |
| URI | https://labmedonline.org/journal/download_pdf.php?doi=10.47429/lmo.2022.12.1.33 https://www.kci.go.kr/kciportal/ci/sereArticleSearch/ciSereArtiView.kci?sereArticleSearchBean.artiId=ART002794614 |
| UnpaywallVersion | publishedVersion |
| Volume | 12 |
| hasFullText | 1 |
| inHoldings | 1 |
| isFullTextHit | |
| isPrint | |
| ispartofPNX | Laboratory Medicine Online, 2022, 12(1), , pp.33-39 |
| journalDatabaseRights | – providerCode: PRVERR databaseName: KoreaMed Open Access customDbUrl: eissn: 2093-6338 dateEnd: 99991231 omitProxy: true ssIdentifier: ssib008307499 issn: 2093-6338 databaseCode: 5-W dateStart: 20110101 isFulltext: true titleUrlDefault: https://koreamed.org/journals providerName: Korean Association of Medical Journal Editors |
| link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwrV1bS8MwFA5ue_DJCypOdATxSWm3rvfHOR1TcIo4nU8hl1MZq20ZHaK_3pO2ExVBBKG0fUhLc5LmfF-S8x1Cjnhoe2ADGJbyleFEng5WjizD9cEBEUKgiiwRVyNvOHYuJ-5khVwvY2Gw6ugFSpWIYiG_Mmlbae34lCuWqagQjsBfHhGs6SC3C9vxsw7k63b11J5l2naNNDwXwXmdNMajm96jTjGH3N3wkJGVa5s_P_fFO9WSOZ5XF0nGX194HH9yPIN1ki0_udxvMjMXuTDl2zc1x3-s0wZZq0Aq7ZW9apOsQLJF2D1C9jIDE00jOtRir8WcPL3l2VTREsqjJ6SlCjpFOEz1cIM9A-ip3iBP-xDHVIfB51RPANOzKj0LDjPxNhkPzu_6Q6NKz2BIC2GfESoOHgjugeJaxw3BgJQgBUSCI2x0I7dgl55ADik60leuEFHXlsB9RBl4t0PqSZrALqEgbUciMeQiwJcINwxU4CgLhwceCR_sJjleNgvLShUOhuylsBNDOzFtJ2bhwWwsfIgNx2ZyyrR2tr4-pWw2Z8gQLhh6X8fqBE1y8tGuv79y70-l90k9ny_gANFKLlqk5hoPraofvgOIs-ya |
| linkProvider | Unpaywall |
| linkToUnpaywall | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwrV1dS8MwFA1ue_DJD1ScqATxSWm3rm3aPs7pmIJTxMl8Cvm4lbHalrEh-uu9aTtREUQQStuHtDQ3ae45Se65hByLyGXgAliODrTlxcwEK8eO5QfggYwg1EWWiOshG4y8q7E_XiE3y1gYrDp6gVIloljIr0za0kY7PhOa5zouhCPwl0cEa3vI7aJW8mwC-TodM7Xn2K5bIw3mIzivk8ZoeNt9NCnmkLtbDBlZubb583NfvFMtneF5dZHm4vVFJMknx9NfJ_nyk8v9JlN7MZe2evum5viPddogaxVIpd2yV22SFUi3CH9AyF5mYKJZTAdG7LWYk6d3Ip9oWkJ59IS0VEGnCIepGW6wZwA9MxvkaQ-ShJow-Dk1E8D0vErPgsNMsk1G_Yv73sCq0jNYykHYZ0VaAAMpGGhhdNwQDCgFSkIsBcJGP_YLdskkckjZVoH2pYw7rgIRIMrAux1ST7MUdgkF5XoKiaGQIb5E-lGoQ087ODyIWAbgNsnJsll4XqpwcGQvhZ042okbO3EHD-5i4SNsOD5VE260s831KePTGUeGcMnR-3pOO2yS0492_f2Ve38qvU_q89kCDhCtzOVh1QPfAQMo68A |
| openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Validation+of+Hematology+Rapid+Reporting+System+for+Complete+Blood+Cell+Count+with+Differential&rft.jtitle=Laboratory+Medicine+Online%2C+12%281%29&rft.au=%EC%9D%B4%EC%A0%95%EB%AF%BC&rft.au=%EC%9C%A4%EC%88%98%EC%98%81&rft.au=%EB%B0%95%EC%A7%80%EC%98%81&rft.au=%EA%B9%80%EC%A7%80%EC%9A%A9&rft.date=2022-01-01&rft.pub=%EB%8C%80%ED%95%9C%EC%A7%84%EB%8B%A8%EA%B2%80%EC%82%AC%EC%9D%98%ED%95%99%ED%9A%8C&rft.eissn=2093-6338&rft.spage=33&rft.epage=39&rft_id=info:doi/10.47429%2Flmo.2022.12.1.33&rft.externalDBID=n%2Fa&rft.externalDocID=oai_kci_go_kr_ARTI_9904108 |
| thumbnail_l | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=2093-6338&client=summon |
| thumbnail_m | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=2093-6338&client=summon |
| thumbnail_s | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=2093-6338&client=summon |