Abridgment of circuit breaker recovery voltages: Magnitudes and rates of rise
This paper shows the conditions affecting the magnitude and rate of rise of recovery voltage at the terminals of an oil circuit breaker upon interruption of a short circuit; also explaining their effect in quantitative terms. The most common locations, and a rough idea of the magnitude of the capaci...
Saved in:
Published in | Journal of the A.I.E.E. Vol. 49; no. 12; pp. 1017 - 1021 |
---|---|
Main Authors | , |
Format | Journal Article |
Language | English |
Published |
The American Institute of Electrical Engineers
01.12.1930
|
Subjects | |
Online Access | Get full text |
ISSN | 0095-9804 2376-5976 |
DOI | 10.1109/JAIEE.1930.6537542 |
Cover
Abstract | This paper shows the conditions affecting the magnitude and rate of rise of recovery voltage at the terminals of an oil circuit breaker upon interruption of a short circuit; also explaining their effect in quantitative terms. The most common locations, and a rough idea of the magnitude of the capacitances affecting the rate of rise of recovery voltage for various types of short circuit, are indicated, and calculations of the recovery voltage curve for several representative cases at both low and high voltages are presented. In some cases cathode ray oscillograms are given for comparison with the calculated curves. While at present no systematic data regarding the effect of the rate of recovery voltage rise upon circuit breaker operation appear to be available, several tests showing a very pronounced effect - some of them made by the authors and some by others - are reported briefly. There are presented factors whose numerical value lakes into account: the number of phases involved in the short circuit and the ground connections of short circuit and generator; the decrement of short-circuit current previous to interruption, and the effect of unequal reactances in the direct and quadrature axes of synchronous machines. The paper also indicates how one may calculate the effect of displacement and initial load current, besides briefly discussing the effect of saturation. Magnetic oscillograms to verify the most important of the points brought out are shown. A discussion of the method by which overvoltages are built up during the interruption of transmission line charging currents is presented at the end of the paper. |
---|---|
AbstractList | This paper shows the conditions affecting the magnitude and rate of rise of recovery voltage at the terminals of an oil circuit breaker upon interruption of a short circuit; also explaining their effect in quantitative terms. The most common locations, and a rough idea of the magnitude of the capacitances affecting the rate of rise of recovery voltage for various types of short circuit, are indicated, and calculations of the recovery voltage curve for several representative cases at both low and high voltages are presented. In some cases cathode ray oscillograms are given for comparison with the calculated curves. While at present no systematic data regarding the effect of the rate of recovery voltage rise upon circuit breaker operation appear to be available, several tests showing a very pronounced effect - some of them made by the authors and some by others - are reported briefly. There are presented factors whose numerical value lakes into account: the number of phases involved in the short circuit and the ground connections of short circuit and generator; the decrement of short-circuit current previous to interruption, and the effect of unequal reactances in the direct and quadrature axes of synchronous machines. The paper also indicates how one may calculate the effect of displacement and initial load current, besides briefly discussing the effect of saturation. Magnetic oscillograms to verify the most important of the points brought out are shown. A discussion of the method by which overvoltages are built up during the interruption of transmission line charging currents is presented at the end of the paper. |
Author | Park, Robert H. Skeats, Wilfred F. |
Author_xml | – sequence: 1 givenname: Robert H. surname: Park fullname: Park, Robert H. organization: Stone and Webster Corporation – sequence: 2 givenname: Wilfred F. surname: Skeats fullname: Skeats, Wilfred F. organization: General Electric Co., Schenectady, N. Y |
BookMark | eNp9kMFOAjEQhhuDiYi8gF76AovT7na79UYIKgbiRc-bbjslVdg1bSXh7V0EPXjwNJPMfP-ffJdk0HYtEnLNYMIYqNun6WI-nzCVw6QUuRQFPyNDnssyE0qWAzIEUCJTFRQXZBzjGwAwkBLyakhW0yZ4u95im2jnqPHBfPpEm4D6HQMNaLodhj3ddZuk1xjv6EqvW58-LUaqW0uDTv3Wo8FHvCLnTm8ijk9zRF7v5y-zx2z5_LCYTZeZYYzzDHMjC84NVxbAldwZYVExWwlRqLJoGmNBCt5Y6ZhjJValhab_ywsHzMoiHxF-zDWhizGgqz-C3-qwrxnUByf1t5P64KQ-Oemh6g9kfNLJd20K2m_-R2-OqEfE366f6xfTPHEq |
CitedBy_id | crossref_primary_10_1109_T_AIEE_1931_5055825 |
ContentType | Journal Article |
DBID | AAYXX CITATION |
DOI | 10.1109/JAIEE.1930.6537542 |
DatabaseName | CrossRef |
DatabaseTitle | CrossRef |
DatabaseTitleList | |
DeliveryMethod | fulltext_linktorsrc |
Discipline | Engineering |
EISSN | 2376-5976 |
EndPage | 1021 |
ExternalDocumentID | 10_1109_JAIEE_1930_6537542 6537542 |
Genre | orig-research |
GroupedDBID | 0R~ 6IK AAFWJ AAJGR AAWTH ABAZT ABQJQ ABVLG ACGFS AFFNX AGQYO AHBIQ AI. ALLEH ALMA_UNASSIGNED_HOLDINGS BEFXN BFFAM BGNUA BKEBE BPEOZ IEQBH IFIPE IPLJI JAVBF M43 O9- OCL RIE RNS TN5 VH1 AAYXX CITATION |
ID | FETCH-LOGICAL-c1122-e3c7422c29d00f62fc5de91d8554964bbcd0752bd7f1f16e86d0bf6234f01d743 |
IEDL.DBID | RIE |
ISSN | 0095-9804 |
IngestDate | Tue Jul 01 04:18:02 EDT 2025 Thu Apr 24 23:03:24 EDT 2025 Wed Aug 27 02:11:52 EDT 2025 |
IsPeerReviewed | false |
IsScholarly | false |
Issue | 12 |
Language | English |
License | https://ieeexplore.ieee.org/Xplorehelp/downloads/license-information/IEEE.html https://doi.org/10.15223/policy-029 https://doi.org/10.15223/policy-037 |
LinkModel | DirectLink |
MergedId | FETCHMERGED-LOGICAL-c1122-e3c7422c29d00f62fc5de91d8554964bbcd0752bd7f1f16e86d0bf6234f01d743 |
PageCount | 5 |
ParticipantIDs | crossref_primary_10_1109_JAIEE_1930_6537542 crossref_citationtrail_10_1109_JAIEE_1930_6537542 ieee_primary_6537542 |
ProviderPackageCode | CITATION AAYXX |
PublicationCentury | 1900 |
PublicationDate | 1930-Dec. 1930-12-00 |
PublicationDateYYYYMMDD | 1930-12-01 |
PublicationDate_xml | – month: 12 year: 1930 text: 1930-Dec. |
PublicationDecade | 1930 |
PublicationTitle | Journal of the A.I.E.E. |
PublicationTitleAbbrev | JAIEE |
PublicationYear | 1930 |
Publisher | The American Institute of Electrical Engineers |
Publisher_xml | – name: The American Institute of Electrical Engineers |
SSID | ssj0001077038 |
Score | 1.1485367 |
Snippet | This paper shows the conditions affecting the magnitude and rate of rise of recovery voltage at the terminals of an oil circuit breaker upon interruption of a... |
SourceID | crossref ieee |
SourceType | Enrichment Source Index Database Publisher |
StartPage | 1017 |
SubjectTerms | Capacitance Circuit breakers Circuit faults Generators Impedance Wheels Windings |
Title | Abridgment of circuit breaker recovery voltages: Magnitudes and rates of rise |
URI | https://ieeexplore.ieee.org/document/6537542 |
Volume | 49 |
hasFullText | 1 |
inHoldings | 1 |
isFullTextHit | |
isPrint | |
journalDatabaseRights | – providerCode: PRVIEE databaseName: IEEE Xplore customDbUrl: eissn: 2376-5976 dateEnd: 19301231 omitProxy: false ssIdentifier: ssj0001077038 issn: 0095-9804 databaseCode: RIE dateStart: 19240101 isFulltext: true titleUrlDefault: https://ieeexplore.ieee.org/ providerName: IEEE |
link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwjV1LS8QwEA7unvTgW3yTgzdtN03TtPW2iLIsrCcFb6WdTEGUruy2B_31TtLuuoqItxJmQpgMM9-k82DsQqpcJkIWXgqp8lQgwNpB8MI8jAyQRwV0Wb73evSoxk_R0xq7WtbCIKJLPkPffrp_-WYKjX0qG-jIDWztsV4cp22t1td7iohJeVvDa8cPJkItamREOhgPKXbyCawIv9vkmx9aGazi_MrdFpssTtSmk7z4TV348PGjWeN_j7zNNjuAyYetRuywNax22cZK28E9Nhm6Mi3Lyaclh-cZNM81p-A4f8EZtzEyKfg7J8tVk7mZX_NJbpOMGoNznleG2_YSc8tKFgL32ePd7cPNyOvGKnhA4Ep6GALFwxJkaoQotSwhMpgGxiaspVoVBRjCEbIwcRmUgcZEG1EQXahKERhCHAesX00rPGQcosiIMFcJKq00oYVSE3WMskQgICOPWLAQcgZdz3E7-uI1c7GHSDN3MZm9mKwT1RG7XPK8tR03_qTes0JfUnbLx78vn7B1y9ymo5yyfj1r8IxARV2cO236BMMmxlI |
linkProvider | IEEE |
linkToHtml | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwjV1LT-MwEB7xOACHXZ5adnn4wA0SHMdxm71VK1B5lBNI3KJkPJEqULtqkwP8esZOWh5CiFtkzVjWeDTzjTMPgCOlc9WVqghSTHWgI4nODmIQ53FikT0qks_yvTH9O315n9wvwMm8FoaIfPIZhe7T_8u3Y6zdU9mpSfzA1kVYTjiq6DTVWq8vKrLD6tuYXjeAsCv1rEpGpqeXPY6eQoYrMmy3eeeJ3oxW8Z7l_CcMZmdqEkoewroqQnz-0K7xu4dehx8txBS9Ric2YIFGm7D2pvHgFgx6vlDLcYpxKXA4wXpYCQ6P8weaCBcls4o_CbZdFRuc6V8xyF2aUW1pKvKRFa7BxNSxso2gbbg7P7v91w_awQoBMrxSAcXIEbFClVopS6NKTCylkXUpa6nRRYGWkYQqbKeMyshQ11hZMF2sSxlZxhw7sDQaj-gXCEwSK-Ncd0kbbRgvlIapO6RKQoYyaheimZAzbLuOu-EXj5mPPmSa-YvJ3MVkrah24XjO87_pufEl9ZYT-pyyXf79-fIhrPRvB9fZ9cXN1R9YdRs1ySl7sFRNatpniFEVB16zXgBd58mj |
openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Abridgment+of+circuit+breaker+recovery+voltages%3A+Magnitudes+and+rates+of+rise&rft.jtitle=Journal+of+the+A.I.E.E.&rft.au=Park%2C+Robert+H.&rft.au=Skeats%2C+Wilfred+F.&rft.date=1930-12-01&rft.issn=0095-9804&rft.eissn=2376-5976&rft.volume=49&rft.issue=12&rft.spage=1017&rft.epage=1021&rft_id=info:doi/10.1109%2FJAIEE.1930.6537542&rft.externalDBID=n%2Fa&rft.externalDocID=10_1109_JAIEE_1930_6537542 |
thumbnail_l | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=0095-9804&client=summon |
thumbnail_m | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=0095-9804&client=summon |
thumbnail_s | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=0095-9804&client=summon |