TU-AB-207A-01: Image Acquisition Physics and Hardware

Practicing medical physicists are often time charged with the tasks of evaluating and troubleshooting complex image quality issues related to CT scanners. This course will equip them with a solid and practical understanding of common CT imaging chain and its major components with emphasis on acquisi...

Full description

Saved in:
Bibliographic Details
Published inMedical physics (Lancaster) Vol. 43; no. 6; pp. 3739 - 3740
Main Author Li, B.
Format Journal Article
LanguageEnglish
Published American Association of Physicists in Medicine 01.06.2016
Subjects
Online AccessGet full text
ISSN0094-2405
2473-4209
DOI10.1118/1.4957436

Cover

Abstract Practicing medical physicists are often time charged with the tasks of evaluating and troubleshooting complex image quality issues related to CT scanners. This course will equip them with a solid and practical understanding of common CT imaging chain and its major components with emphasis on acquisition physics and hardware, reconstruction, artifacts, image quality, dose, and advanced clinical applications. The core objective is to explain the effects of these major system components on the image quality. This course will not focus on the rapid-changing advanced technologies given the two-hour time limit, but the fundamental principles discussed in this course may facilitate better understanding of those more complicated technologies. The course will begin with an overview of CT acquisition physics and geometry. X-ray tube and CT detector are important acquisition hardware critical to the overall image quality. Each of these two subsystems consists of several major components. An in-depth description of the function and failure modes of these components will be provided. Examples of artifacts related to these failure modes will be presented: off-focal radiation, tube arcing, heel effect, oil bubble, offset drift effect, cross-talk effect, and bad pixels. The fundamentals of CT image reconstruction will first be discussed on an intuitive level. Approaches that do not require rigorous derivation of mathematical formulations will be presented. This is followed by a detailed derivation of the Fourier slice theorem: the foundation of the FBP algorithm. FBP for parallel-beam, fan-beam, and cone-beam geometries will be discussed. To address the issue of radiation dose related to x-ray CT, recent advances in iterative reconstruction, their advantages, and clinical applications will also be described. Because of the nature of fundamental physics and mathematics, limitations in data acquisition, and non-ideal conditions of major system components, image artifact often arise in the reconstructed images. Because of the limited scope of this course, only major imaging artifacts, their appearance, and possible mitigation and corrections will be discussed. Assessment of the performance of a CT scanner is a complicated subject. Procedures to measure common image quality metrics such as high contrast spatial resolution, low contrast detectability, and slice profile will be described. The reason why these metrics used for FBP may not be sufficient for statistical iterative reconstruction will be explained. Optimizing radiation dose requires comprehension of CT dose metrics. This course will briefly describe various dose metrics, and interaction with acquisition parameters and patient habitus. CT is among the most frequently used imaging tools due to its superior image quality, easy to operate, and a broad range of applications. This course will present several interesting CT applications such as a mobile CT unit on an ambulance for stroke patients, low dose lung cancer screening, and single heartbeat cardiac CT. Learning Objectives: 1. Understand the function and impact of major components of X-ray tube on the image quality. 2. Understand the function and impact of major components of CT detector on the image quality. 3. Be familiar with the basic procedure of CT image reconstruction. 4. Understand the effect of image reconstruction on CT image quality and artifacts. 5. Understand the root causes of common CT image artifacts. 6. Be familiar with image quality metrics especially high and low contrast resolution, noise power spectrum, slice sensitivity profile, etc. 7. Understand why basic image quality metrics used for FBP may not be sufficient to characterize the performance of advanced iterative reconstruction. 8. Be familiar with various CT dose metrics and their interaction with acquisition parameters. 9. New development in advanced CT clinical applications. JH: Employee of GE Healthcare. FD: No disclosure.; J. Hsieh, Jiang Hsieh is an employee of GE Healthcare.
AbstractList Practicing medical physicists are often time charged with the tasks of evaluating and troubleshooting complex image quality issues related to CT scanners. This course will equip them with a solid and practical understanding of common CT imaging chain and its major components with emphasis on acquisition physics and hardware, reconstruction, artifacts, image quality, dose, and advanced clinical applications. The core objective is to explain the effects of these major system components on the image quality. This course will not focus on the rapid-changing advanced technologies given the two-hour time limit, but the fundamental principles discussed in this course may facilitate better understanding of those more complicated technologies. The course will begin with an overview of CT acquisition physics and geometry. X-ray tube and CT detector are important acquisition hardware critical to the overall image quality. Each of these two subsystems consists of several major components. An in-depth description of the function and failure modes of these components will be provided. Examples of artifacts related to these failure modes will be presented: off-focal radiation, tube arcing, heel effect, oil bubble, offset drift effect, cross-talk effect, and bad pixels. The fundamentals of CT image reconstruction will first be discussed on an intuitive level. Approaches that do not require rigorous derivation of mathematical formulations will be presented. This is followed by a detailed derivation of the Fourier slice theorem: the foundation of the FBP algorithm. FBP for parallel-beam, fan-beam, and cone-beam geometries will be discussed. To address the issue of radiation dose related to x-ray CT, recent advances in iterative reconstruction, their advantages, and clinical applications will also be described. Because of the nature of fundamental physics and mathematics, limitations in data acquisition, and non-ideal conditions of major system components, image artifact often arise in the reconstructed images. Because of the limited scope of this course, only major imaging artifacts, their appearance, and possible mitigation and corrections will be discussed. Assessment of the performance of a CT scanner is a complicated subject. Procedures to measure common image quality metrics such as high contrast spatial resolution, low contrast detectability, and slice profile will be described. The reason why these metrics used for FBP may not be sufficient for statistical iterative reconstruction will be explained. Optimizing radiation dose requires comprehension of CT dose metrics. This course will briefly describe various dose metrics, and interaction with acquisition parameters and patient habitus. CT is among the most frequently used imaging tools due to its superior image quality, easy to operate, and a broad range of applications. This course will present several interesting CT applications such as a mobile CT unit on an ambulance for stroke patients, low dose lung cancer screening, and single heartbeat cardiac CT. Learning Objectives: 1. Understand the function and impact of major components of X-ray tube on the image quality. 2. Understand the function and impact of major components of CT detector on the image quality. 3. Be familiar with the basic procedure of CT image reconstruction. 4. Understand the effect of image reconstruction on CT image quality and artifacts. 5. Understand the root causes of common CT image artifacts. 6. Be familiar with image quality metrics especially high and low contrast resolution, noise power spectrum, slice sensitivity profile, etc. 7. Understand why basic image quality metrics used for FBP may not be sufficient to characterize the performance of advanced iterative reconstruction. 8. Be familiar with various CT dose metrics and their interaction with acquisition parameters. 9. New development in advanced CT clinical applications. JH: Employee of GE Healthcare. FD: No disclosure.; J. Hsieh, Jiang Hsieh is an employee of GE Healthcare.
Practicing medical physicists are often time charged with the tasks of evaluating and troubleshooting complex image quality issues related to CT scanners. This course will equip them with a solid and practical understanding of common CT imaging chain and its major components with emphasis on acquisition physics and hardware, reconstruction, artifacts, image quality, dose, and advanced clinical applications. The core objective is to explain the effects of these major system components on the image quality. This course will not focus on the rapid‐changing advanced technologies given the two‐hour time limit, but the fundamental principles discussed in this course may facilitate better understanding of those more complicated technologies. The course will begin with an overview of CT acquisition physics and geometry. X‐ray tube and CT detector are important acquisition hardware critical to the overall image quality. Each of these two subsystems consists of several major components. An in‐depth description of the function and failure modes of these components will be provided. Examples of artifacts related to these failure modes will be presented: off‐focal radiation, tube arcing, heel effect, oil bubble, offset drift effect, cross‐talk effect, and bad pixels. The fundamentals of CT image reconstruction will first be discussed on an intuitive level. Approaches that do not require rigorous derivation of mathematical formulations will be presented. This is followed by a detailed derivation of the Fourier slice theorem: the foundation of the FBP algorithm. FBP for parallel‐beam, fan‐beam, and cone‐beam geometries will be discussed. To address the issue of radiation dose related to x‐ray CT, recent advances in iterative reconstruction, their advantages, and clinical applications will also be described. Because of the nature of fundamental physics and mathematics, limitations in data acquisition, and non‐ideal conditions of major system components, image artifact often arise in the reconstructed images. Because of the limited scope of this course, only major imaging artifacts, their appearance, and possible mitigation and corrections will be discussed. Assessment of the performance of a CT scanner is a complicated subject. Procedures to measure common image quality metrics such as high contrast spatial resolution, low contrast detectability, and slice profile will be described. The reason why these metrics used for FBP may not be sufficient for statistical iterative reconstruction will be explained. Optimizing radiation dose requires comprehension of CT dose metrics. This course will briefly describe various dose metrics, and interaction with acquisition parameters and patient habitus. CT is among the most frequently used imaging tools due to its superior image quality, easy to operate, and a broad range of applications. This course will present several interesting CT applications such as a mobile CT unit on an ambulance for stroke patients, low dose lung cancer screening, and single heartbeat cardiac CT. Learning Objectives: 1.Understand the function and impact of major components of X‐ray tube on the image quality. 2.Understand the function and impact of major components of CT detector on the image quality. 3.Be familiar with the basic procedure of CT image reconstruction. 4.Understand the effect of image reconstruction on CT image quality and artifacts. 5.Understand the root causes of common CT image artifacts. 6.Be familiar with image quality metrics especially high and low contrast resolution, noise power spectrum, slice sensitivity profile, etc. 7.Understand why basic image quality metrics used for FBP may not be sufficient to characterize the performance of advanced iterative reconstruction. 8.Be familiar with various CT dose metrics and their interaction with acquisition parameters. 9.New development in advanced CT clinical applications. JH: Employee of GE Healthcare. FD: No disclosure.; J. Hsieh, Jiang Hsieh is an employee of GE Healthcare.
Abstract only Practicing medical physicists are often time charged with the tasks of evaluating and troubleshooting complex image quality issues related to CT scanners. This course will equip them with a solid and practical understanding of common CT imaging chain and its major components with emphasis on acquisition physics and hardware, reconstruction, artifacts, image quality, dose, and advanced clinical applications. The core objective is to explain the effects of these major system components on the image quality. This course will not focus on the rapid‐changing advanced technologies given the two‐hour time limit, but the fundamental principles discussed in this course may facilitate better understanding of those more complicated technologies. The course will begin with an overview of CT acquisition physics and geometry. X‐ray tube and CT detector are important acquisition hardware critical to the overall image quality. Each of these two subsystems consists of several major components. An in‐depth description of the function and failure modes of these components will be provided. Examples of artifacts related to these failure modes will be presented: off‐focal radiation, tube arcing, heel effect, oil bubble, offset drift effect, cross‐talk effect, and bad pixels. The fundamentals of CT image reconstruction will first be discussed on an intuitive level. Approaches that do not require rigorous derivation of mathematical formulations will be presented. This is followed by a detailed derivation of the Fourier slice theorem: the foundation of the FBP algorithm. FBP for parallel‐beam, fan‐beam, and cone‐beam geometries will be discussed. To address the issue of radiation dose related to x‐ray CT, recent advances in iterative reconstruction, their advantages, and clinical applications will also be described. Because of the nature of fundamental physics and mathematics, limitations in data acquisition, and non‐ideal conditions of major system components, image artifact often arise in the reconstructed images. Because of the limited scope of this course, only major imaging artifacts, their appearance, and possible mitigation and corrections will be discussed. Assessment of the performance of a CT scanner is a complicated subject. Procedures to measure common image quality metrics such as high contrast spatial resolution, low contrast detectability, and slice profile will be described. The reason why these metrics used for FBP may not be sufficient for statistical iterative reconstruction will be explained. Optimizing radiation dose requires comprehension of CT dose metrics. This course will briefly describe various dose metrics, and interaction with acquisition parameters and patient habitus. CT is among the most frequently used imaging tools due to its superior image quality, easy to operate, and a broad range of applications. This course will present several interesting CT applications such as a mobile CT unit on an ambulance for stroke patients, low dose lung cancer screening, and single heartbeat cardiac CT. Learning Objectives: Understand the function and impact of major components of X‐ray tube on the image quality. Understand the function and impact of major components of CT detector on the image quality. Be familiar with the basic procedure of CT image reconstruction. Understand the effect of image reconstruction on CT image quality and artifacts. Understand the root causes of common CT image artifacts. Be familiar with image quality metrics especially high and low contrast resolution, noise power spectrum, slice sensitivity profile, etc. Understand why basic image quality metrics used for FBP may not be sufficient to characterize the performance of advanced iterative reconstruction. Be familiar with various CT dose metrics and their interaction with acquisition parameters. New development in advanced CT clinical applications. JH: Employee of GE Healthcare. FD: No disclosure.; J. Hsieh, Jiang Hsieh is an employee of GE Healthcare.
Author Li, B.
Author_xml – sequence: 1
  givenname: B.
  surname: Li
  fullname: Li, B.
BookMark eNp9j09LwzAchoNMsJse_Aa9KmT-8qdJ462O6QYTd9jOIUtTjWytJpPRb-9Ke9XTCy8PL-8zRqO6qR1CtwSmhJD8gUy5yiRn4gIllEuGOQU1QgmA4phyyK7QOMZPABAsgwRlmy0unjAFWWAgj-nyYN5dWtjvHx_90Td1uv5oo7cxNXWZLkwoTya4a3RZmX10N0NO0PZ5vpkt8OrtZTkrVtgSkALnYMFYU0onmOMycxU7PwPVNVVOzY4xUkpKgamcW6kE2wlWUkd4xSnLJZugu37XhibG4Cr9FfzBhFYT0J2vJnrwPbO4Z09-79q_Qf26Hvj7no_WH02n-s_4Lyi7YHM
CODEN MPHYA6
ContentType Journal Article
Copyright American Association of Physicists in Medicine
2016 American Association of Physicists in Medicine
Copyright_xml – notice: American Association of Physicists in Medicine
– notice: 2016 American Association of Physicists in Medicine
DBID AAYXX
CITATION
DOI 10.1118/1.4957436
DatabaseName CrossRef
DatabaseTitle CrossRef
DatabaseTitleList

CrossRef
DeliveryMethod fulltext_linktorsrc
Discipline Medicine
Physics
EISSN 2473-4209
EndPage 3740
ExternalDocumentID 10_1118_1_4957436
MP7436
Genre miscellaneous
GroupedDBID ---
--Z
-DZ
.GJ
0R~
1OB
1OC
29M
2WC
33P
36B
3O-
4.4
476
53G
5GY
5RE
5VS
AAHHS
AANLZ
AAQQT
AASGY
AAXRX
AAZKR
ABCUV
ABEFU
ABFTF
ABJNI
ABLJU
ABQWH
ABTAH
ABXGK
ACAHQ
ACBEA
ACCFJ
ACCZN
ACGFO
ACGFS
ACGOF
ACPOU
ACSMX
ACXBN
ACXQS
ADBBV
ADBTR
ADKYN
ADOZA
ADXAS
ADZMN
AEEZP
AEGXH
AEIGN
AENEX
AEQDE
AEUYR
AFBPY
AFFPM
AHBTC
AIACR
AIAGR
AIURR
AIWBW
AJBDE
ALMA_UNASSIGNED_HOLDINGS
ALUQN
AMYDB
ASPBG
BFHJK
C45
CS3
DCZOG
DRFUL
DRMAN
DRSTM
DU5
EBD
EBS
EJD
EMB
EMOBN
F5P
G8K
HDBZQ
HGLYW
I-F
KBYEO
LATKE
LEEKS
LOXES
LUTES
LYRES
MEWTI
O9-
OVD
P2P
P2W
PALCI
PHY
RJQFR
RNS
ROL
SAMSI
SUPJJ
SV3
TEORI
TN5
TWZ
USG
WOHZO
WXSBR
XJT
ZGI
ZVN
ZXP
ZY4
ZZTAW
AAHQN
AAIPD
AAMMB
AAMNL
AAYCA
ABDPE
ADMLS
AEFGJ
AEYWJ
AFWVQ
AGHNM
AGXDD
AGYGG
AIDQK
AIDYY
AITYG
ALVPJ
AAYXX
CITATION
ID FETCH-LOGICAL-c1076-80c0acad7e63e475ef343609ad7ef82ab331d72203984c7963b63d2e14f423873
ISSN 0094-2405
IngestDate Tue Jul 01 03:54:15 EDT 2025
Wed Aug 20 07:25:59 EDT 2025
Fri Jun 21 00:19:33 EDT 2024
IsPeerReviewed true
IsScholarly true
Issue 6
Language English
License http://onlinelibrary.wiley.com/termsAndConditions#vor
LinkModel OpenURL
MergedId FETCHMERGED-LOGICAL-c1076-80c0acad7e63e475ef343609ad7ef82ab331d72203984c7963b63d2e14f423873
PageCount 2
ParticipantIDs wiley_primary_10_1118_1_4957436_MP7436
crossref_primary_10_1118_1_4957436
scitation_primary_10_1118_1_4957436
ProviderPackageCode CITATION
AAYXX
PublicationCentury 2000
PublicationDate 20160600
June 2016
2016-06-00
PublicationDateYYYYMMDD 2016-06-01
PublicationDate_xml – month: 06
  year: 2016
  text: 20160600
PublicationDecade 2010
PublicationTitle Medical physics (Lancaster)
PublicationYear 2016
Publisher American Association of Physicists in Medicine
Publisher_xml – name: American Association of Physicists in Medicine
SSID ssj0006350
Score 2.170517
Snippet Practicing medical physicists are often time charged with the tasks of evaluating and troubleshooting complex image quality issues related to CT scanners. This...
Abstract only Practicing medical physicists are often time charged with the tasks of evaluating and troubleshooting complex image quality issues related to CT...
SourceID crossref
wiley
scitation
SourceType Index Database
Publisher
StartPage 3739
SubjectTerms Computed tomography
Germanium
Image sensors
Medical image artifacts
Medical image contrast
Medical image reconstruction
Medical X‐ray imaging
Vacuum tubes
Title TU-AB-207A-01: Image Acquisition Physics and Hardware
URI http://dx.doi.org/10.1118/1.4957436
https://onlinelibrary.wiley.com/doi/abs/10.1118%2F1.4957436
Volume 43
hasFullText 1
inHoldings 1
isFullTextHit
isPrint
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV1bS8MwFA664eVFdCreKSq-dTaXNa0-dV5Q2WTgBr6VXlLwwaljQ_DJn-Bv9Jd40qTZplPUl7QLyUrytSffSc4Fof3Y5T4nKbMjVzCbecK1YyxThqWpLxjPPJq7Rzev3YsOu7qt3Q4TF-beJf24mrxM9Cv5D6pQB7hKL9k_IGv-FCrgHvCFEhCG8ncYd4ytQlA3t8ThgfnhYKnzX95L05wgeRrcKRutPOdNEaBZnt4_R70xo6DiAOdRt5OZP-T2h0rkYXYPGrkxQL06unmA3aGRUyEQfSYPWNTBssjrCOPUZsTxR4WkiqWkXwa3BUOmdETuUa5CEuk1lHIVg2mCfJY-B7gKahlQlwkxsD-tTcZiUOkqXohD3XUalQkHulRC5eC02bgxyy8wKOV3pEemw0lB50Pz3DESMgdcQ5k9jCsoOcNoL6IFrRpYgcJ5CU2JbgXNNrXxQwXNaMyW0XG78_76FtShkGDDxcFHVg6yNQKypTtYALJVgLyCOudn7ZMLW2fBsBNQzWW06MSJkijlwqXw9dRERmEEji9rMo9EMaU45YQ41PdYwkGgxi5NicAsA6rscbqKSt2HrlhDFpXBCFP4bCMgoqzm-Snoy1lMuY-zmmDOOtotpiV8VMFOwi8Tv472zIT91Oogn8rvW4TNlrxs_OaZm2h--PZuoVK_NxDbQAb78Y6G_wOPwFCH
linkProvider EBSCOhost
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=TU%E2%80%90AB%E2%80%90207A%E2%80%9001%3A+Image+Acquisition+Physics+and+Hardware&rft.jtitle=Medical+physics+%28Lancaster%29&rft.au=Li%2C+B.&rft.date=2016-06-01&rft.issn=0094-2405&rft.eissn=2473-4209&rft.volume=43&rft.issue=6Part33&rft.spage=3739&rft.epage=3740&rft_id=info:doi/10.1118%2F1.4957436&rft.externalDBID=n%2Fa&rft.externalDocID=10_1118_1_4957436
thumbnail_l http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=0094-2405&client=summon
thumbnail_m http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=0094-2405&client=summon
thumbnail_s http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=0094-2405&client=summon