Influence of LASIK on scanning laser polarimetric measurement of the retinal nerve fibre layer with fixed angle and customised corneal polarisation compensation

Background/aim: Retinal nerve fibre layer thickness (RNFLT), as measured with scanning laser polarimetry using the fixed angle corneal polarisation compensator (SLP-F), has been found to be reduced after uncomplicated laser assisted in situ keratomileusis (LASIK) compared to the pre-LASIK measuremen...

Full description

Saved in:
Bibliographic Details
Published inBritish journal of ophthalmology Vol. 87; no. 10; pp. 1241 - 1246
Main Authors Holló, G, Katsanos, A, Kóthy, P, Kerek, A, Süveges, I
Format Journal Article
LanguageEnglish
Published BMA House, Tavistock Square, London, WC1H 9JR BMJ Publishing Group Ltd 01.10.2003
BMJ
BMJ Publishing Group LTD
2003 British Journal of Ophthalmology
Subjects
Online AccessGet full text
ISSN0007-1161
1468-2079
1468-2079
DOI10.1136/bjo.87.10.1241

Cover

Abstract Background/aim: Retinal nerve fibre layer thickness (RNFLT), as measured with scanning laser polarimetry using the fixed angle corneal polarisation compensator (SLP-F), has been found to be reduced after uncomplicated laser assisted in situ keratomileusis (LASIK) compared to the pre-LASIK measurement. Since this virtual RNFLT thinning is attributed to the corneal changes induced by the LASIK, the authors investigated whether customised corneal polarisation compensation (SLP-C), which compensates for the actual corneal polarisation during each measurement, can avoid the LASIK induced, virtual changes of the polarimetric RNFLT values. Methods: Scanning laser polarimetry using both the SLP-F and SLP-C methods (GDx-Access, software version 5.0) was performed on 15 consecutive healthy subjects with no eye disease who underwent LASIK for ametropia correction. The SLP measurements were performed before the surgery, then on day 1 and day 6 after LASIK. Thickness data from images of one randomly selected eye per subject were analysed using the ANOVA and Scheffe multiple comparison tests. Results: Superior maximum, inferior maximum, normalised superior area, and normalised inferior area (SLP parameters representing the RNFLT at the superior and inferior poles of the optic nerve head) remained unchanged with SLP-C (ANOVA, p>0.05) but decreased (superior maximum, normalised superior area, Scheffe test, p<0.05) or tended to decrease (inferior maximum) after LASIK, when measured using SLP-F. In contrast, certain other parameters—namely, superior ratio and inferior ratio (representing the ratios between the superior or the inferior sector and the temporal sector), maximal modulation, and ellipse modulation decreased with SLP-C (Scheffe test, p<0.05), but remained stable with SLP-F (ANOVA, p>0.05) after LASIK. Superior to nasal ratio, symmetry of the superior and inferior RNFLT as well as the parameter showing the probability of having glaucoma (called “the number”) remained unchanged with both types of corneal compensation (ANOVA, p>0.05). With SLP-C the parameter ellipse average thickness increased after LASIK (Scheffe test, p = 0.021). No parameter value altered between day 1 and day 6 after LASIK, for either method. Conclusion: The results suggest that the LASIK induced decrease of the polarimetric RNFLT, which is consistently detected with polarimeters when using the fixed angle corneal polarisation compensator, is due to alterations of the corneal polarisation. The use of customised corneal polarisation compensation avoids this virtual decrease of the polarimetric RNFLTHowever, our results suggestan increase of the measured retardation in the temporal quadrant of the SLP-C image after LASIK. Since ratios of parameters using the temporal RNFLT in the denominator are important in the polarimetric glaucoma diagnosis algorithm, their decrease as a consequence of using SLP-C needs further investigation.
AbstractList Background/aim: Retinal nerve fibre layer thickness (RNFLT), as measured with scanning laser polarimetry using the fixed angle corneal polarisation compensator (SLP-F), has been found to be reduced after uncomplicated laser assisted in situ keratomileusis (LASIK) compared to the pre-LASIK measurement. Since this virtual RNFLT thinning is attributed to the corneal changes induced by the LASIK, the authors investigated whether customised corneal polarisation compensation (SLP-C), which compensates for the actual corneal polarisation during each measurement, can avoid the LASIK induced, virtual changes of the polarimetric RNFLT values. Methods: Scanning laser polarimetry using both the SLP-F and SLP-C methods (GDx-Access, software version 5.0) was performed on 15 consecutive healthy subjects with no eye disease who underwent LASIK for ametropia correction. The SLP measurements were performed before the surgery, then on day 1 and day 6 after LASIK. Thickness data from images of one randomly selected eye per subject were analysed using the ANOVA and Scheffe multiple comparison tests. Results: Superior maximum, inferior maximum, normalised superior area, and normalised inferior area (SLP parameters representing the RNFLT at the superior and inferior poles of the optic nerve head) remained unchanged with SLP-C (ANOVA, p>0.05) but decreased (superior maximum, normalised superior area, Scheffe test, p<0.05) or tended to decrease (inferior maximum) after LASIK, when measured using SLP-F. In contrast, certain other parameters-namely, superior ratio and inferior ratio (representing the ratios between the superior or the inferior sector and the temporal sector), maximal modulation, and ellipse modulation decreased with SLP-C (Scheffe test, p<0.05), but remained stable with SLP-F (ANOVA, p>0.05) after LASIK. Superior to nasal ratio, symmetry of the superior and inferior RNFLT as well as the parameter showing the probability of having glaucoma (called "the number") remained unchanged with both types of corneal compensation (ANOVA, p>0.05). With SLP-C the parameter ellipse average thickness increased after LASIK (Scheffe test, p = 0.021). No parameter value altered between day 1 and day 6 after LASIK, for either method. Conclusion: The results suggest that the LASIK induced decrease of the polarimetric RNFLT, which is consistently detected with polarimeters when using the fixed angle corneal polarisation compensator, is due to alterations of the corneal polarisation. The use of customised corneal polarisation compensation avoids this virtual decrease of the polarimetric RNFLTHowever, our results suggestan increase of the measured retardation in the temporal quadrant of the SLP-C image after LASIK. Since ratios of parameters using the temporal RNFLT in the denominator are important in the polarimetric glaucoma diagnosis algorithm, their decrease as a consequence of using SLP-C needs further investigation.
Retinal nerve fibre layer thickness (RNFLT), as measured with scanning laser polarimetry using the fixed angle corneal polarisation compensator (SLP-F), has been found to be reduced after uncomplicated laser assisted in situ keratomileusis (LASIK) compared to the pre-LASIK measurement. Since this virtual RNFLT thinning is attributed to the corneal changes induced by the LASIK, the authors investigated whether customised corneal polarisation compensation (SLP-C), which compensates for the actual corneal polarisation during each measurement, can avoid the LASIK induced, virtual changes of the polarimetric RNFLT values. Scanning laser polarimetry using both the SLP-F and SLP-C methods (GDx-Access, software version 5.0) was performed on 15 consecutive healthy subjects with no eye disease who underwent LASIK for ametropia correction. The SLP measurements were performed before the surgery, then on day 1 and day 6 after LASIK. Thickness data from images of one randomly selected eye per subject were analysed using the ANOVA and Scheffe multiple comparison tests. Superior maximum, inferior maximum, normalised superior area, and normalised inferior area (SLP parameters representing the RNFLT at the superior and inferior poles of the optic nerve head) remained unchanged with SLP-C (ANOVA, p>0.05) but decreased (superior maximum, normalised superior area, Scheffe test, p<0.05) or tended to decrease (inferior maximum) after LASIK, when measured using SLP-F. In contrast, certain other parameters-namely, superior ratio and inferior ratio (representing the ratios between the superior or the inferior sector and the temporal sector), maximal modulation, and ellipse modulation decreased with SLP-C (Scheffe test, p<0.05), but remained stable with SLP-F (ANOVA, p>0.05) after LASIK. Superior to nasal ratio, symmetry of the superior and inferior RNFLT as well as the parameter showing the probability of having glaucoma (called "the number") remained unchanged with both types of corneal compensation (ANOVA, p>0.05). With SLP-C the parameter ellipse average thickness increased after LASIK (Scheffe test, p = 0.021). No parameter value altered between day 1 and day 6 after LASIK, for either method. The results suggest that the LASIK induced decrease of the polarimetric RNFLT, which is consistently detected with polarimeters when using the fixed angle corneal polarisation compensator, is due to alterations of the corneal polarisation. The use of customised corneal polarisation compensation avoids this virtual decrease of the polarimetric RNFLTHowever, our results suggest an increase of the measured retardation in the temporal quadrant of the SLP-C image after LASIK. Since ratios of parameters using the temporal RNFLT in the denominator are important in the polarimetric glaucoma diagnosis algorithm, their decrease as a consequence of using SLP-C needs further investigation.
Retinal nerve fibre layer thickness (RNFLT), as measured with scanning laser polarimetry using the fixed angle corneal polarisation compensator (SLP-F), has been found to be reduced after uncomplicated laser assisted in situ keratomileusis (LASIK) compared to the pre-LASIK measurement. Since this virtual RNFLT thinning is attributed to the corneal changes induced by the LASIK, the authors investigated whether customised corneal polarisation compensation (SLP-C), which compensates for the actual corneal polarisation during each measurement, can avoid the LASIK induced, virtual changes of the polarimetric RNFLT values.BACKGROUND/AIMRetinal nerve fibre layer thickness (RNFLT), as measured with scanning laser polarimetry using the fixed angle corneal polarisation compensator (SLP-F), has been found to be reduced after uncomplicated laser assisted in situ keratomileusis (LASIK) compared to the pre-LASIK measurement. Since this virtual RNFLT thinning is attributed to the corneal changes induced by the LASIK, the authors investigated whether customised corneal polarisation compensation (SLP-C), which compensates for the actual corneal polarisation during each measurement, can avoid the LASIK induced, virtual changes of the polarimetric RNFLT values.Scanning laser polarimetry using both the SLP-F and SLP-C methods (GDx-Access, software version 5.0) was performed on 15 consecutive healthy subjects with no eye disease who underwent LASIK for ametropia correction. The SLP measurements were performed before the surgery, then on day 1 and day 6 after LASIK. Thickness data from images of one randomly selected eye per subject were analysed using the ANOVA and Scheffe multiple comparison tests.METHODSScanning laser polarimetry using both the SLP-F and SLP-C methods (GDx-Access, software version 5.0) was performed on 15 consecutive healthy subjects with no eye disease who underwent LASIK for ametropia correction. The SLP measurements were performed before the surgery, then on day 1 and day 6 after LASIK. Thickness data from images of one randomly selected eye per subject were analysed using the ANOVA and Scheffe multiple comparison tests.Superior maximum, inferior maximum, normalised superior area, and normalised inferior area (SLP parameters representing the RNFLT at the superior and inferior poles of the optic nerve head) remained unchanged with SLP-C (ANOVA, p>0.05) but decreased (superior maximum, normalised superior area, Scheffe test, p<0.05) or tended to decrease (inferior maximum) after LASIK, when measured using SLP-F. In contrast, certain other parameters-namely, superior ratio and inferior ratio (representing the ratios between the superior or the inferior sector and the temporal sector), maximal modulation, and ellipse modulation decreased with SLP-C (Scheffe test, p<0.05), but remained stable with SLP-F (ANOVA, p>0.05) after LASIK. Superior to nasal ratio, symmetry of the superior and inferior RNFLT as well as the parameter showing the probability of having glaucoma (called "the number") remained unchanged with both types of corneal compensation (ANOVA, p>0.05). With SLP-C the parameter ellipse average thickness increased after LASIK (Scheffe test, p = 0.021). No parameter value altered between day 1 and day 6 after LASIK, for either method.RESULTSSuperior maximum, inferior maximum, normalised superior area, and normalised inferior area (SLP parameters representing the RNFLT at the superior and inferior poles of the optic nerve head) remained unchanged with SLP-C (ANOVA, p>0.05) but decreased (superior maximum, normalised superior area, Scheffe test, p<0.05) or tended to decrease (inferior maximum) after LASIK, when measured using SLP-F. In contrast, certain other parameters-namely, superior ratio and inferior ratio (representing the ratios between the superior or the inferior sector and the temporal sector), maximal modulation, and ellipse modulation decreased with SLP-C (Scheffe test, p<0.05), but remained stable with SLP-F (ANOVA, p>0.05) after LASIK. Superior to nasal ratio, symmetry of the superior and inferior RNFLT as well as the parameter showing the probability of having glaucoma (called "the number") remained unchanged with both types of corneal compensation (ANOVA, p>0.05). With SLP-C the parameter ellipse average thickness increased after LASIK (Scheffe test, p = 0.021). No parameter value altered between day 1 and day 6 after LASIK, for either method.The results suggest that the LASIK induced decrease of the polarimetric RNFLT, which is consistently detected with polarimeters when using the fixed angle corneal polarisation compensator, is due to alterations of the corneal polarisation. The use of customised corneal polarisation compensation avoids this virtual decrease of the polarimetric RNFLTHowever, our results suggest an increase of the measured retardation in the temporal quadrant of the SLP-C image after LASIK. Since ratios of parameters using the temporal RNFLT in the denominator are important in the polarimetric glaucoma diagnosis algorithm, their decrease as a consequence of using SLP-C needs further investigation.CONCLUSIONThe results suggest that the LASIK induced decrease of the polarimetric RNFLT, which is consistently detected with polarimeters when using the fixed angle corneal polarisation compensator, is due to alterations of the corneal polarisation. The use of customised corneal polarisation compensation avoids this virtual decrease of the polarimetric RNFLTHowever, our results suggest an increase of the measured retardation in the temporal quadrant of the SLP-C image after LASIK. Since ratios of parameters using the temporal RNFLT in the denominator are important in the polarimetric glaucoma diagnosis algorithm, their decrease as a consequence of using SLP-C needs further investigation.
Audience Professional
Academic
Author Kerek, A
Kóthy, P
Holló, G
Süveges, I
Katsanos, A
AuthorAffiliation 1 1st Department of Ophthalmology, Semmelweis University, Budapest, Hungary
2 Optimum Private Laser Eye Institute, Budapest, Hungary
AuthorAffiliation_xml – name: 1 1st Department of Ophthalmology, Semmelweis University, Budapest, Hungary
– name: 2 Optimum Private Laser Eye Institute, Budapest, Hungary
Author_xml – sequence: 1
  givenname: G
  surname: Holló
  fullname: Holló, G
  organization: Optimum Private Laser Eye Institute, Budapest, Hungary
– sequence: 2
  givenname: A
  surname: Katsanos
  fullname: Katsanos, A
  organization: Optimum Private Laser Eye Institute, Budapest, Hungary
– sequence: 3
  givenname: P
  surname: Kóthy
  fullname: Kóthy, P
  organization: Optimum Private Laser Eye Institute, Budapest, Hungary
– sequence: 4
  givenname: A
  surname: Kerek
  fullname: Kerek, A
  organization: Optimum Private Laser Eye Institute, Budapest, Hungary
– sequence: 5
  givenname: I
  surname: Süveges
  fullname: Süveges, I
  organization: Optimum Private Laser Eye Institute, Budapest, Hungary
BackLink http://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&idt=15149658$$DView record in Pascal Francis
https://www.ncbi.nlm.nih.gov/pubmed/14507758$$D View this record in MEDLINE/PubMed
BookMark eNqFkk2P0zAQhiO0iP2AK0cUCYHEIV07aeLkglRVLFRbgfgUN8txxq2LYxc72d3-G34q06aisFq0ipRoJs87Y78zp9GRdRai6CklI0qz4rxeuVHJRtswHdMH0QkdF2WSElYdRSeEEJZQWtDj6DSEFYZpQdmj6JiOc8JYXp5Ev2ZWmR6shNipeD75PLuMnY2DFNZqu4iNCODjtTPC6xY6r2Xcggi9hxZst9V0S4g9dNoKE1vwVxArXXtA5QaV17pbYuIGmljYhQF8N7HsQ-daHTApnbeAyqFDEJ3G7tK1a7BD8Dh6qIQJ8GT_PYu-Xrz5Mn2XzD-8nU0n86TOq6xLsobQpqKCpkrmsqCkrhtS0LqULC_SWlZ5IYRoxmlRQSkzyFitMiVrplilGtFkZ9H5ULe3a7G5FsbwNV5Z-A2nhG-95ug1L9kuRK9R8XpQrPu6hUaiH14cVE5o_u8fq5d84a44rbbzIVjg5b6Adz97CB1HTyQYIyy4PnCWMxxeWSL4_Ba4cr1HwwOnjJVYKqMpUslALYQBrq1y2FUuAIciDG6N0pieUFLRlBSsQn50B49PA62Wdwqe_X3hgz_7bULgxR4QuEBGeWGlDgcup-Oq2HHjgZPeheBBcam73bTxBNr83_DRLdm9E9o7okMHN39o4X_wgmUs5--_Tfmn7OLjd5qX_BL5VwNft6v7av8GR88adw
CODEN BJOPAL
CitedBy_id crossref_primary_10_1038_sj_eye_6701431
crossref_primary_10_1016_j_jcrs_2005_12_069
crossref_primary_10_1007_s00417_009_1273_5
crossref_primary_10_1016_j_ajo_2003_11_041
crossref_primary_10_1016_j_jcrs_2004_09_054
crossref_primary_10_3928_1081_597X_20050902_13
crossref_primary_10_3928_1542_8877_20050901_08
crossref_primary_10_1177_112067210501500402
crossref_primary_10_1007_s00347_005_1197_3
crossref_primary_10_1016_j_ophtha_2004_08_019
crossref_primary_10_1097_01_ijg_0000195598_24763_98
crossref_primary_10_3928_1081_597X_20050501_18
crossref_primary_10_1016_j_jbiomech_2013_04_008
crossref_primary_10_1097_01_ijg_0000212286_55174_2e
crossref_primary_10_1556_APhysiol_91_2004_2_4
crossref_primary_10_1038_sj_eye_6701429
crossref_primary_10_1016_j_jcrs_2004_12_045
crossref_primary_10_1016_S0181_5512_07_89631_8
ContentType Journal Article
Copyright 2003 British Orthodontic Society
2004 INIST-CNRS
COPYRIGHT 2003 BMJ Publishing Group Ltd.
Copyright: 2003 (c) 2003 British Orthodontic Society
2003 British Journal of Ophthalmology 2003
Copyright_xml – notice: 2003 British Orthodontic Society
– notice: 2004 INIST-CNRS
– notice: COPYRIGHT 2003 BMJ Publishing Group Ltd.
– notice: Copyright: 2003 (c) 2003 British Orthodontic Society
– notice: 2003 British Journal of Ophthalmology 2003
DBID BSCLL
AAYXX
CITATION
IQODW
CGR
CUY
CVF
ECM
EIF
NPM
3V.
7X7
7XB
88E
8FI
8FJ
8FK
ABUWG
AFKRA
BENPR
BTHHO
CCPQU
FYUFA
GHDGH
K9.
M0S
M1P
PHGZM
PHGZT
PJZUB
PKEHL
PPXIY
PQEST
PQQKQ
PQUKI
7X8
5PM
ADTOC
UNPAY
DOI 10.1136/bjo.87.10.1241
DatabaseName Istex
CrossRef
Pascal-Francis
Medline
MEDLINE
MEDLINE (Ovid)
MEDLINE
MEDLINE
PubMed
ProQuest Central (Corporate)
Health & Medical Collection
ProQuest Central (purchase pre-March 2016)
Medical Database (Alumni Edition)
Hospital Premium Collection
Hospital Premium Collection (Alumni Edition)
ProQuest Central (Alumni) (purchase pre-March 2016)
ProQuest Central (Alumni)
ProQuest Central UK/Ireland
ProQuest Central
BMJ Journals
ProQuest One Community College
Health Research Premium Collection
Health Research Premium Collection (Alumni)
ProQuest Health & Medical Complete (Alumni)
Health & Medical Collection (Alumni)
Medical Database
ProQuest Central Premium
ProQuest One Academic (New)
ProQuest Health & Medical Research Collection
ProQuest One Academic Middle East (New)
ProQuest One Health & Nursing
ProQuest One Academic Eastern Edition (DO NOT USE)
ProQuest One Academic
ProQuest One Academic UKI Edition
MEDLINE - Academic
PubMed Central (Full Participant titles)
Unpaywall for CDI: Periodical Content
Unpaywall
DatabaseTitle CrossRef
MEDLINE
Medline Complete
MEDLINE with Full Text
PubMed
MEDLINE (Ovid)
ProQuest One Academic Middle East (New)
ProQuest One Academic Eastern Edition
ProQuest Health & Medical Complete (Alumni)
ProQuest Central (Alumni Edition)
ProQuest One Community College
ProQuest One Health & Nursing
ProQuest Hospital Collection
Health Research Premium Collection (Alumni)
ProQuest Hospital Collection (Alumni)
ProQuest Central
ProQuest Health & Medical Complete
Health Research Premium Collection
ProQuest Medical Library
ProQuest One Academic UKI Edition
Health and Medicine Complete (Alumni Edition)
BMJ Journals
Health & Medical Research Collection
ProQuest Central (New)
ProQuest One Academic
ProQuest One Academic (New)
ProQuest Medical Library (Alumni)
ProQuest Central (Alumni)
MEDLINE - Academic
DatabaseTitleList ProQuest One Academic Middle East (New)
MEDLINE
MEDLINE - Academic



Database_xml – sequence: 1
  dbid: NPM
  name: PubMed
  url: https://proxy.k.utb.cz/login?url=http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed
  sourceTypes: Index Database
– sequence: 2
  dbid: EIF
  name: MEDLINE
  url: https://proxy.k.utb.cz/login?url=https://www.webofscience.com/wos/medline/basic-search
  sourceTypes: Index Database
– sequence: 3
  dbid: UNPAY
  name: Unpaywall
  url: https://proxy.k.utb.cz/login?url=https://unpaywall.org/
  sourceTypes: Open Access Repository
– sequence: 4
  dbid: BENPR
  name: ProQuest Central
  url: http://www.proquest.com/pqcentral?accountid=15518
  sourceTypes: Aggregation Database
DeliveryMethod fulltext_linktorsrc
Discipline Medicine
EISSN 1468-2079
EndPage 1246
ExternalDocumentID 10.1136/bjo.87.10.1241
PMC1920790
4012345401
A109120679
14507758
15149658
10_1136_bjo_87_10_1241
ark_67375_NVC_R3FQX158_K
bjophthalmol
Genre Research Support, Non-U.S. Gov't
Journal Article
GeographicLocations United Kingdom
GeographicLocations_xml – name: United Kingdom
GroupedDBID ---
-~X
.55
.GJ
.VT
0R~
18M
23N
2WC
354
39C
3O-
4.4
40O
53G
5GY
5RE
5VS
6J9
7X7
7~S
88E
8FI
8FJ
8R4
8R5
AAHLL
AAKAS
AAOJX
AAWJN
ABAAH
ABJNI
ABKDF
ABMQD
ABTFR
ABUWG
ABVAJ
ACCCW
ACGFO
ACGFS
ACGTL
ACHTP
ACMFJ
ACNCT
ACOAB
ACOFX
ACQSR
ACTZY
ADBBV
ADCEG
ADZCM
AENEX
AFKRA
AFWFF
AGQPQ
AHMBA
AHNKE
AHQMW
AJYBZ
ALIPV
ALMA_UNASSIGNED_HOLDINGS
ASPBG
AVWKF
AZFZN
BAWUL
BENPR
BLJBA
BOMFT
BPHCQ
BTFSW
BTHHO
BVXVI
C1A
C45
CAG
CCPQU
COF
CS3
CXRWF
DIK
DU5
E3Z
EBS
EJD
F5P
FYUFA
H13
HAJ
HMCUK
HYE
HZ~
IAO
IEA
IHR
IOF
ITC
J5H
KQ8
L7B
M1P
N9A
NTWIH
NXWIF
O9-
OK1
OVD
P2P
PHGZT
PQQKQ
PROAC
PSQYO
Q2X
R53
RHI
RMJ
RPM
RV8
TEORI
TR2
UAW
UKHRP
UYXKK
V24
VM9
W8F
WH7
WOQ
X7M
XOL
YFH
YQY
ZGI
3V.
BSCLL
RHF
AAFWJ
AAYXX
ACQHZ
AERUA
CITATION
PHGZM
PJZUB
PPXIY
PUEGO
IQODW
CGR
CUY
CVF
ECM
EIF
NPM
PMFND
7XB
8FK
K9.
PKEHL
PQEST
PQUKI
7X8
5PM
ADTOC
UNPAY
ID FETCH-LOGICAL-b593t-3d01d91a12fc5c610bbd061b8c7562bc956aaad4269e8c3e37bf3fcb7f79fdad3
IEDL.DBID 7X7
ISSN 0007-1161
1468-2079
IngestDate Tue Aug 19 17:42:39 EDT 2025
Tue Sep 30 15:32:40 EDT 2025
Fri Sep 05 07:38:45 EDT 2025
Sat Jul 26 02:30:05 EDT 2025
Fri Jun 13 01:08:56 EDT 2025
Tue Jun 10 21:31:14 EDT 2025
Thu Jan 02 23:03:58 EST 2025
Mon Jul 21 09:11:50 EDT 2025
Wed Oct 01 01:40:13 EDT 2025
Thu Apr 24 23:08:24 EDT 2025
Wed Oct 30 09:23:59 EDT 2024
Thu Apr 24 23:05:32 EDT 2025
IsDoiOpenAccess true
IsOpenAccess true
IsPeerReviewed true
IsScholarly true
Issue 10
Keywords Human
Measurement
Cornea
Scanning
Keratomileusis
In situ
Retina
Thickness
Nerve
Eye
Surgery
Compensation
Laser
Measurement method
Polarimetry
Nerve fiber
Language English
License CC BY 4.0
LinkModel DirectLink
MergedId FETCHMERGED-LOGICAL-b593t-3d01d91a12fc5c610bbd061b8c7562bc956aaad4269e8c3e37bf3fcb7f79fdad3
Notes ark:/67375/NVC-R3FQX158-K
local:0871241
istex:FB77E577267C9F1BC7DA2EBDABD06E976C42E3D6
PMID:14507758
Correspondence to: Gábor Holló MD, 1st Department of Ophthalmology, Semmelweis University, H-1083, Budapest, Tömö u, 25–29, Hungary; hg@szem1.sote.hu
href:bjophthalmol-87-1241.pdf
ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 14
content type line 23
Correspondence to: … Gábor Holló MD, 1st Department of Ophthalmology, Semmelweis University, H-1083, Budapest, Tömö u, 25–29, Hungary; …hg@szem1.sote.hu
OpenAccessLink https://proxy.k.utb.cz/login?url=https://bjo.bmj.com/content/bjophthalmol/87/10/1241.full.pdf
PMID 14507758
PQID 1778903312
PQPubID 2041039
PageCount 6
ParticipantIDs unpaywall_primary_10_1136_bjo_87_10_1241
pubmedcentral_primary_oai_pubmedcentral_nih_gov_1920790
proquest_miscellaneous_75711688
proquest_journals_1778903312
gale_infotracgeneralonefile_A109120679
gale_infotracacademiconefile_A109120679
pubmed_primary_14507758
pascalfrancis_primary_15149658
crossref_citationtrail_10_1136_bjo_87_10_1241
crossref_primary_10_1136_bjo_87_10_1241
istex_primary_ark_67375_NVC_R3FQX158_K
bmj_primary_10_1136_bjo_87_10_1241
ProviderPackageCode CITATION
AAYXX
PublicationCentury 2000
PublicationDate 2003-10-01
PublicationDateYYYYMMDD 2003-10-01
PublicationDate_xml – month: 10
  year: 2003
  text: 2003-10-01
  day: 01
PublicationDecade 2000
PublicationPlace BMA House, Tavistock Square, London, WC1H 9JR
PublicationPlace_xml – name: BMA House, Tavistock Square, London, WC1H 9JR
– name: London
– name: England
PublicationTitle British journal of ophthalmology
PublicationTitleAlternate Br J Ophthalmol
PublicationYear 2003
Publisher BMJ Publishing Group Ltd
BMJ
BMJ Publishing Group LTD
2003 British Journal of Ophthalmology
Publisher_xml – name: BMJ Publishing Group Ltd
– name: BMJ
– name: BMJ Publishing Group LTD
– name: 2003 British Journal of Ophthalmology
SSID ssj0002617
Score 1.831868
Snippet Background/aim: Retinal nerve fibre layer thickness (RNFLT), as measured with scanning laser polarimetry using the fixed angle corneal polarisation compensator...
Retinal nerve fibre layer thickness (RNFLT), as measured with scanning laser polarimetry using the fixed angle corneal polarisation compensator (SLP-F), has...
SourceID unpaywall
pubmedcentral
proquest
gale
pubmed
pascalfrancis
crossref
istex
bmj
SourceType Open Access Repository
Aggregation Database
Index Database
Enrichment Source
Publisher
StartPage 1241
SubjectTerms Adult
Aged
Analysis
Analysis of Variance
Biological and medical sciences
Blindness
Care and treatment
Clinical Science - Extended Reports
Comparative analysis
Compensation
Cornea
corneal compensator
Glaucoma
Health aspects
Humans
Keratomileusis, Laser In Situ
Lasers
LASIK
Medical sciences
Methodology
Methods
Microscopy, Polarization
Middle Aged
Nerve Fibers
Optic Nerve - anatomy & histology
Optics
Polariscope
Postoperative Period
Prevention
Ratios
Refractive Surgical Procedures
Retina - anatomy & histology
Retinal diseases
retinal nerve fibre layer thickness
scanning laser polarimetry
Software
Surgery
Surgery (general aspects). Transplantations, organ and tissue grafts. Graft diseases
Surgery of the eye and orbit
Tomography
Visually disabled persons
SummonAdditionalLinks – databaseName: Unpaywall
  dbid: UNPAY
  link: http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV3db9MwELe2VgJe-P4IjGEhxHhJltRNnEi8VBPVxljFV1F5QJbt2Ou2NqnaVAz-Gv5U7pK0pTA0xEulxI7tXM_275y73xHyTKoQUHzSck3kaxcQsXIV7JNubCMZ-YnhKsLY4aNetN9vvx6Egw3ychELo05zT41Pq2gG5GfKCrw3GRZDORrno90YQ8V3YVcKPDyg9iap3STNCD8vNUiz33vb-VwhXu4GQUWXisFFLZ8nNWdjwKKym5h7JbsCJoPfhD7XdqZ6fW6irM_RYVLOQGa2SnZxERr906ny6jybyG9f5Wj0y47VvUG-LN61clQ58-aF8vT332gg_1cYN8n1GsrSTqV7t8iGyW6TK0f1x_o75MfBIgEKzS190_lwcEjzjMIblmmSKOB2M6UTtK1PxpjYS9Px6sQSnwFwSjHKErvJ0DWTWrDuDTwJhgLFI2S4cW5SKrPjkYHflOo5oFnQXbgJdnUGMLjuofJaouhCD5Z7eXGX9LuvPu7tu3VCCFeFCStclvpBmgQyaFkdagB-SqWAR1SsOcA4pcHWk1KmGJ1rYs0M48oyqxW3PLGpTNk90sjyzDwglEfGtsF6C6wv2zIBM1HHCsBaO9SW-SpxyFOQvJhUlB-iNJVYJED6IublJQjdIe5CY4SuKdUxs8for_V3lvUva3kHFVDgKgMtalkHS8Dgka9LdJDPFZn3YaDP12oeV2zlF1YslXnZs5yeoVcfD0Xv0554z7rvBkEYi0OHbK9p-2qoAK6RK8ghWwv1F_WKNxMBx5BqxoKWQ54si-H_xg9QMjP5fCZ4yGFOxtDA_WqurJpuh8jFCCV8bRYtKyAL-npJdjIs2dDBRIG57TvkxXK-XSLch_9e9RG5tvLe3CKNYjo3jwGFFmq7Xmx-Aurxh-Q
  priority: 102
  providerName: Unpaywall
Title Influence of LASIK on scanning laser polarimetric measurement of the retinal nerve fibre layer with fixed angle and customised corneal polarisation compensation
URI http://bjo.bmj.com/content/87/10/1241.full
https://api.istex.fr/ark:/67375/NVC-R3FQX158-K/fulltext.pdf
https://www.ncbi.nlm.nih.gov/pubmed/14507758
https://www.proquest.com/docview/1778903312
https://www.proquest.com/docview/75711688
https://pubmed.ncbi.nlm.nih.gov/PMC1920790
https://bjo.bmj.com/content/bjophthalmol/87/10/1241.full.pdf
UnpaywallVersion publishedVersion
Volume 87
hasFullText 1
inHoldings 1
isFullTextHit
isPrint
journalDatabaseRights – providerCode: PRVAFT
  databaseName: Open Access Digital Library
  customDbUrl:
  eissn: 1468-2079
  dateEnd: 20051231
  omitProxy: true
  ssIdentifier: ssj0002617
  issn: 0007-1161
  databaseCode: KQ8
  dateStart: 19170101
  isFulltext: true
  titleUrlDefault: http://grweb.coalliance.org/oadl/oadl.html
  providerName: Colorado Alliance of Research Libraries
– providerCode: PRVBFR
  databaseName: Free Medical Journals
  customDbUrl:
  eissn: 1468-2079
  dateEnd: 20071231
  omitProxy: true
  ssIdentifier: ssj0002617
  issn: 0007-1161
  databaseCode: DIK
  dateStart: 19170101
  isFulltext: true
  titleUrlDefault: http://www.freemedicaljournals.com
  providerName: Flying Publisher
– providerCode: PRVAQN
  databaseName: PubMed Central Free
  customDbUrl:
  eissn: 1468-2079
  dateEnd: 20071231
  omitProxy: true
  ssIdentifier: ssj0002617
  issn: 0007-1161
  databaseCode: RPM
  dateStart: 19170101
  isFulltext: true
  titleUrlDefault: https://www.ncbi.nlm.nih.gov/pmc/
  providerName: National Library of Medicine
– providerCode: PRVPQU
  databaseName: Health & Medical Collection
  customDbUrl:
  eissn: 1468-2079
  dateEnd: 20250403
  omitProxy: true
  ssIdentifier: ssj0002617
  issn: 0007-1161
  databaseCode: 7X7
  dateStart: 19220101
  isFulltext: true
  titleUrlDefault: https://search.proquest.com/healthcomplete
  providerName: ProQuest
– providerCode: PRVPQU
  databaseName: ProQuest Central
  customDbUrl: http://www.proquest.com/pqcentral?accountid=15518
  eissn: 1468-2079
  dateEnd: 20250403
  omitProxy: true
  ssIdentifier: ssj0002617
  issn: 0007-1161
  databaseCode: BENPR
  dateStart: 19220101
  isFulltext: true
  titleUrlDefault: https://www.proquest.com/central
  providerName: ProQuest
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwhV1bb9MwFLbYKgEviDsZo1gIMV6yJXUTJ0-oTKs2xqoxKOqeLNuxx7Y2Kb2I8W_4qZyTuCkVg71EcnyVfWx_xz7-DiGvpYoAxact38SB9gERK1_BPuknNpZxkBquYnw7fNSL9_vtD4No4A7cps6scrEmlgt1Vmg8I98JOT7ZZCxsvRt_99FrFN6uOhcaa6QRAlRBqeaDWuEq2cYr-Mv9EKCNI20MWbyjLorthG-X9AroDX5NjS5Wtia3QDews6_QYlJOodNs5e3iOjj6t1XlnXk-lj9_yOHwjy2re5_cc1iTdirheEBumfwhuX3kbtMfkV8HCw8ltLD0Y-fzwSEtcgotKP0YUQDWZkLHqPyej9Dzlqaj5ZEi5gH0SPEZJFaTo-0ktaB-G8gJSJ7iGS_8uDIZlfnZ0MA3o3oOcBOEC36C4psDTnU1VGZFFG3cQbUuA49Jv7v3ZXffdx4bfBWlbOazLAizNJRhy-pIAzJTKgPAoBLNAWcpDcqYlDLD57Mm0cwwriyzWnHLU5vJjD0h63mRm2eE8tjYNqhXoQ1kW6agx-lEAZpqR9qyQKUeeQVDJsYVJ4codRkWCxhXkfAyCOPqEX8xokI7znN0vTH8Z_qtOv1NJW-hgAhcBqBELd1rBmg8EmqJDhKuIjU-NPTNSsqzik782oSlsNU1y8klmt3xSPS-7ooT1v00CKNEHHqkuSKNy6YC-kUyH49sLsRTuCVpKpYTyCMv62gYb7whkrkp5lPBIw7zJIECnlayvCy6HSFZIsTwFSmvEyBN-WpMfv6tpCuHiRnwNPDI23o-3NC5G_9v_3Nyd2lSuUnWZ5O5eQHQcKaa5fxvksb7vd7xSbM8u4NQv3fcOf0Ny6ZoBA
linkProvider ProQuest
linkToHtml http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwtV1bb9MwFLZ2kRgviDuBsVkIGC_ZkjqJkweEqkHV0nYSsE19M7bjjI02Kb1o27_hF_AbOSe3UjHY014qJXZsq-fY_o59zncIeSmVDyg-atgmcLQNiFjZCvZJO0wCGTiR4SrA2OH-QdA-8j4O_MEK-VXFwqBbZbUm5gt1nGk8I99zOYZsMuY23o1_2Jg1Cm9XqxQahVp0zeU5mGzTt533IN9XjUbrw-F-2y6zCtjKj9jMZrHjxpEr3UaifQ3oQakYNjUVag5YQGkwGKSUMYZ4mlAzw7hKWKIVT3iUxDJm0O4qWfeY4yFXPx_UBl7Obl7AbW67AKVKkkiXBXvqLNsN-W5O54DZ51fV6GxpKyw3hHUU7gV6aMopCCkpsmtcBX__9uLcmKdjeXkuh8M_tsjWXXKnxLa0WSjjPbJi0vvkVr-8vX9AfnaqjCg0S2iv-aXTpVlKYQR53iQKQN5M6BiN7dMRZvrSdLQ4wsRvAK1SDLvEblL01aQJmPsGvgTLgeKZMry4MDGV6cnQwG9M9RzgLSgzvARDOwVcXPZQuDFR9KkHUz5_eEiObkSWj8hamqXmCaE8MIkH5pybONKTEdiNOlSA3jxfJ8xRkUVegMjEuOAAEbntxAIBchUhzx9BrhaxK4kKXXKsY6qP4T_r79T1r2t5BxVE4LIDLWpZRk_A4JHASzSR4BWp-GGgr5dqnhT05VdWzJWt7llOvqObH_fFwfG--MxanwauH4quRbaWtHExVEDbSB5kkc1KPUW5BE7FYsJaZLsuBnnjjZRMTTafCu5zmCchNPC40OVF056P5IxQwpe0vK6AtOjLJenpt5weHWwWh0eORd7U8-GaP_fp_8e_TTbah_2e6HUOus_I7YU75yZZm03m5jnA0pnaytcCSr7e9OLzG6VEooA
linkToPdf http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwtV1bb9MwFLZ2kQYviDuBsVkIGC9Zk7qJkweEqo1qpdvEbahvxnbssdEmpRdt-zf8Dn4d5-RWKgZ72kulxI5t9Rwff8c-_g4hz6UKAMXHTdeEnnYBEStXwTrpRjaUoRcbrkK8O3xwGO4dtd71g_4S-VXdhcGwysom5oY6yTTukTd8jlc2GfObDVuGRbzf7bwZ_XAxgxSetFbpNAoV6ZmLM3DfJq-7uyDrF81m5-3nnT23zDDgqiBmU5clnp_EvvSbVgcakIRSCSxwKtIccIHS4DxIKRO87mkizQzjyjKrFbc8tolMGLS7TFY5azEMJ-P92tnLmc4L6M1dH2BVSRjps7ChTrPtiG_n1A6YiX5ZDU8XlsVycVhFQZ9jtKacgMBskWnjMij8d0TnjVk6khdncjD4Y7ns3Ca3SpxL24Vi3iFLJr1L1g7Kk_x75Ge3yo5CM0v325-6PZqlFEaQ51CiAOrNmI7Q8T4ZYtYvTYfz7Uz8BpArxSuY2E2KcZvUgutv4EvwIijuL8OLc5NQmR4PDPwmVM8A6oJiw0twulPAyGUPRUgTxfh6cOvzh_vk6Fpk-YCspFlqHhHKQ2Nb4Nr51pMtGYMPqSMFSK4VaMs8FTvkGYhMjAo-EJH7USwUIFcR8fwR5OoQt5Ko0CXfOqb9GPyz_lZd_6qWt1BBBJogaFHL8iYFDB7JvEQbyV6Rlh8G-nKh5nFBZX5pxVzZ6p7l-DuG_PFAHH7ZER9Z50PfDyLRc8jGgjbOhwrIG4mEHLJeqacozeFEzCevQzbrYpA3nk7J1GSzieABh3kSQQMPC12eN90KkKgRSviCltcVkCJ9sSQ9-ZZTpYP_4vHYc8irej5c8ec-_v_4N8kamB2x3z3sPSE355Gd62RlOp6Zp4BQp2ojNwWUfL1u2_MbS6Omuw
linkToUnpaywall http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV3db9MwELe2VgJe-P4IjGEhxHhJltRNnEi8VBPVxljFV1F5QJbt2Ou2NqnaVAz-Gv5U7pK0pTA0xEulxI7tXM_275y73xHyTKoQUHzSck3kaxcQsXIV7JNubCMZ-YnhKsLY4aNetN9vvx6Egw3ychELo05zT41Pq2gG5GfKCrw3GRZDORrno90YQ8V3YVcKPDyg9iap3STNCD8vNUiz33vb-VwhXu4GQUWXisFFLZ8nNWdjwKKym5h7JbsCJoPfhD7XdqZ6fW6irM_RYVLOQGa2SnZxERr906ny6jybyG9f5Wj0y47VvUG-LN61clQ58-aF8vT332gg_1cYN8n1GsrSTqV7t8iGyW6TK0f1x_o75MfBIgEKzS190_lwcEjzjMIblmmSKOB2M6UTtK1PxpjYS9Px6sQSnwFwSjHKErvJ0DWTWrDuDTwJhgLFI2S4cW5SKrPjkYHflOo5oFnQXbgJdnUGMLjuofJaouhCD5Z7eXGX9LuvPu7tu3VCCFeFCStclvpBmgQyaFkdagB-SqWAR1SsOcA4pcHWk1KmGJ1rYs0M48oyqxW3PLGpTNk90sjyzDwglEfGtsF6C6wv2zIBM1HHCsBaO9SW-SpxyFOQvJhUlB-iNJVYJED6IublJQjdIe5CY4SuKdUxs8for_V3lvUva3kHFVDgKgMtalkHS8Dgka9LdJDPFZn3YaDP12oeV2zlF1YslXnZs5yeoVcfD0Xv0554z7rvBkEYi0OHbK9p-2qoAK6RK8ghWwv1F_WKNxMBx5BqxoKWQ54si-H_xg9QMjP5fCZ4yGFOxtDA_WqurJpuh8jFCCV8bRYtKyAL-npJdjIs2dDBRIG57TvkxXK-XSLch_9e9RG5tvLe3CKNYjo3jwGFFmq7Xmx-Aurxh-Q
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Influence+of+LASIK+on+scanning+laser+polarimetric+measurement+of+the+retinal+nerve+fibre+layer+with+fixed+angle+and+customised+corneal+polarisation+compensation&rft.jtitle=British+journal+of+ophthalmology&rft.au=Holl%C3%B3%2C+G&rft.au=Katsanos%2C+A&rft.au=K%C3%B3thy%2C+P&rft.au=Kerek%2C+A&rft.date=2003-10-01&rft.pub=BMJ+Publishing+Group+LTD&rft.issn=0007-1161&rft.eissn=1468-2079&rft.volume=87&rft.issue=10&rft.spage=1241&rft_id=info:doi/10.1136%2Fbjo.87.10.1241&rft.externalDBID=HAS_PDF_LINK&rft.externalDocID=4012345401
thumbnail_l http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=0007-1161&client=summon
thumbnail_m http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=0007-1161&client=summon
thumbnail_s http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=0007-1161&client=summon