Left atrial size and function: assessment using echocardiographic automatic boundary detection
OBJECTIVE--To evaluate the waveforms of left atrial area changes obtained by automated boundary detection with newly developed acoustic quantification technology. DESIGN--All subjects had measurements of left atrial areas taken in the apical four chamber, parasternal long axis, and parasternal short...
Saved in:
| Published in | British Heart Journal Vol. 74; no. 6; pp. 664 - 670 |
|---|---|
| Main Authors | , , , , |
| Format | Journal Article |
| Language | English |
| Published |
London
BMJ Publishing Group Ltd and British Cardiovascular Society
01.12.1995
BMJ BMJ Publishing Group LTD |
| Subjects | |
| Online Access | Get full text |
| ISSN | 0007-0769 1355-6037 1468-201X 1468-201X 2053-5864 |
| DOI | 10.1136/hrt.74.6.664 |
Cover
| Summary: | OBJECTIVE--To evaluate the waveforms of left atrial area changes obtained by automated boundary detection with newly developed acoustic quantification technology. DESIGN--All subjects had measurements of left atrial areas taken in the apical four chamber, parasternal long axis, and parasternal short axis views using both conventional echocardiographic methods and automatic boundary detection on two occasions separated by at least a week. On the second visit measurements were also repeated in healthy volunteers after acute intravenous volume loading with 1 litre of saline over 2-5 minutes. SETTING--A university medical school echocardiographic laboratory. SUBJECTS--12 healthy male volunteers and 8 patients with cardiac disease (5 with congestive heart failure, 1 with mitral stenosis, and 2 with hypertensive left ventricular hypertrophy, and dilated left atria). RESULTS--There was close correlation between conventionally derived left atrial areas and those obtained by automatic boundary detection, particularly in the apical four chamber view (r = 0.98). Both inter and intra observer variabilities (coefficient of variation) for left atrial areas measured by automatic boundary detection were good (4.7-14.2% and 8.1-18.6% respectively). The reproducibility (coefficient of variation) for derived indices of left atrial function, however, was much poorer (10.4-104.8% and 12.5-88% respectively). After acute volume loading significant increases in left atrial area were observed at all stages in the cardiac cycle. CONCLUSIONS--These data demonstrate that although the reproducibility of left atrial functional indices is poor, instantaneous left atrial cavity measurements with automatic boundary detection are reproducible. This suggests that automatic boundary detection may assist in serial non-invasive measurement of left atrial size to assess disease states and treatments. |
|---|---|
| Bibliography: | istex:AC165D1D9006A234450ED963D95109D54C2047EA PMID:8541175 local:heartjnl;74/6/664 ark:/67375/NVC-40TW1SSW-X href:heartjnl-74-664.pdf ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 14 content type line 23 |
| ISSN: | 0007-0769 1355-6037 1468-201X 1468-201X 2053-5864 |
| DOI: | 10.1136/hrt.74.6.664 |