Multilevel Validation of a Male Neck Finite Element Model With Active Musculature

Computational models of the human neck have been developed to assess human response in impact scenarios; however, the assessment and validation of such models is often limited to a small number of experimental data sets despite being used to evaluate the efficacy of safety systems and potential for...

Full description

Saved in:
Bibliographic Details
Published inJournal of biomechanical engineering Vol. 143; no. 1
Main Authors Barker, Jeffrey B, Cronin, Duane S
Format Journal Article
LanguageEnglish
Published United States 01.01.2021
Subjects
Online AccessGet more information
ISSN1528-8951
DOI10.1115/1.4047866

Cover

Abstract Computational models of the human neck have been developed to assess human response in impact scenarios; however, the assessment and validation of such models is often limited to a small number of experimental data sets despite being used to evaluate the efficacy of safety systems and potential for injury risk in motor vehicle collisions. In this study, a full neck model (NM) with active musculature was developed from previously validated motion segment models of the cervical spine. Tissue mechanical properties were implemented from experimental studies, and were not calibrated. The neck model was assessed with experimental studies at three levels of increasing complexity: ligamentous cervical spine in axial rotation, axial tension, frontal impact, and rear impact; postmortem human subject (PMHS) rear sled impact; and human volunteer frontal and lateral sled tests using an open-loop muscle control strategy. The neck model demonstrated good correlation with the experiments ranging from quasi-static to dynamic, assessed using kinematics, kinetics, and tissue-level response. The contributions of soft tissues, neck curvature, and muscle activation were associated with higher stiffness neck response, particularly for low severity frontal impact. Experiments presenting single-value data limited assessment of the model, while complete load history data and cross-correlation enabled improved evaluation of the model over the full loading history. Tissue-level metrics demonstrated higher variability and therefore lower correlation relative to gross kinematics, and also demonstrated a dependence on the local tissue geometry. Thus, it is critical to assess models at the gross kinematic and the tissue levels.
AbstractList Computational models of the human neck have been developed to assess human response in impact scenarios; however, the assessment and validation of such models is often limited to a small number of experimental data sets despite being used to evaluate the efficacy of safety systems and potential for injury risk in motor vehicle collisions. In this study, a full neck model (NM) with active musculature was developed from previously validated motion segment models of the cervical spine. Tissue mechanical properties were implemented from experimental studies, and were not calibrated. The neck model was assessed with experimental studies at three levels of increasing complexity: ligamentous cervical spine in axial rotation, axial tension, frontal impact, and rear impact; postmortem human subject (PMHS) rear sled impact; and human volunteer frontal and lateral sled tests using an open-loop muscle control strategy. The neck model demonstrated good correlation with the experiments ranging from quasi-static to dynamic, assessed using kinematics, kinetics, and tissue-level response. The contributions of soft tissues, neck curvature, and muscle activation were associated with higher stiffness neck response, particularly for low severity frontal impact. Experiments presenting single-value data limited assessment of the model, while complete load history data and cross-correlation enabled improved evaluation of the model over the full loading history. Tissue-level metrics demonstrated higher variability and therefore lower correlation relative to gross kinematics, and also demonstrated a dependence on the local tissue geometry. Thus, it is critical to assess models at the gross kinematic and the tissue levels.
Author Cronin, Duane S
Barker, Jeffrey B
Author_xml – sequence: 1
  givenname: Jeffrey B
  surname: Barker
  fullname: Barker, Jeffrey B
  organization: Department of MME, University of Waterloo, 200 University Avenue West, Waterloo, ON N2 L 3G1, Canada
– sequence: 2
  givenname: Duane S
  surname: Cronin
  fullname: Cronin, Duane S
  organization: Department of MME, University of Waterloo, 200 University Avenue West, Waterloo, ON N2 L 3G1, Canada
BackLink https://www.ncbi.nlm.nih.gov/pubmed/32696042$$D View this record in MEDLINE/PubMed
BookMark eNo1j8tKw0AUQAdR7EMX_oDMD6TOnUzmsSylVaFRBB_LcpO5wdFpUpJJwb9XUFdnczhwZuy07Vpi7ArEAgCKG1gooYzV-oRNoZA2s66ACZsNw4cQAFaJczbJpXZaKDllT-UYU4h0pMhfMQaPKXQt7xqOvMRI_IHqT74JbUjE15H21CZedv5HfwvpnS_rFI7Ey3Gox4hp7OmCnTUYB7r845y9bNbPq7ts-3h7v1puM8yFThlWkOc-d0JaJYXQKLRtHGnRKFJUSOeNrMDJ2hcGjEKESpMzmlSjrEcj5-z6t3sYqz353aEPe-y_dv9v8humzU4u
CitedBy_id crossref_primary_10_1002_jor_25196
crossref_primary_10_1080_10255842_2022_2112187
crossref_primary_10_4271_09_12_02_0020
crossref_primary_10_1007_s10439_022_03089_7
crossref_primary_10_1002_cnm_3761
crossref_primary_10_1097_JS9_0000000000001941
crossref_primary_10_1016_j_finmec_2022_100163
crossref_primary_10_1093_milmed_usad204
crossref_primary_10_1016_j_jmbbm_2024_106740
crossref_primary_10_3390_biology11071030
crossref_primary_10_1007_s10439_021_02783_2
crossref_primary_10_4271_09_12_03_0014
crossref_primary_10_3389_fbioe_2021_693120
crossref_primary_10_1007_s10439_023_03396_7
crossref_primary_10_1080_15389588_2021_1918685
crossref_primary_10_3389_fbioe_2021_681134
ContentType Journal Article
Copyright Copyright © 2021 by ASME.
Copyright_xml – notice: Copyright © 2021 by ASME.
DBID NPM
DOI 10.1115/1.4047866
DatabaseName PubMed
DatabaseTitle PubMed
DatabaseTitleList PubMed
Database_xml – sequence: 1
  dbid: NPM
  name: PubMed
  url: https://proxy.k.utb.cz/login?url=http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed
  sourceTypes: Index Database
DeliveryMethod no_fulltext_linktorsrc
Discipline Medicine
Engineering
Forestry
EISSN 1528-8951
ExternalDocumentID 32696042
Genre Research Support, Non-U.S. Gov't
Journal Article
GroupedDBID ---
-~X
.DC
29J
4.4
5AI
5GY
ABJNI
ACBEA
ACGFO
ACGFS
ACKMT
ADPDT
AGNGV
ALMA_UNASSIGNED_HOLDINGS
CS3
EBS
F5P
H~9
L7B
NPM
P2P
RAI
RNS
RXW
TAE
TN5
UKR
ID FETCH-LOGICAL-a306t-ab133d3902842006a068f9e60f4e4e529d72b192cd57174aa1b6e976e4f48da72
IngestDate Mon Jul 21 06:03:04 EDT 2025
IsPeerReviewed true
IsScholarly true
Issue 1
Keywords model validation
active muscle
cross-correlation
finite element neck model
human body model
impact
Language English
License Copyright © 2021 by ASME.
LinkModel OpenURL
MergedId FETCHMERGED-LOGICAL-a306t-ab133d3902842006a068f9e60f4e4e529d72b192cd57174aa1b6e976e4f48da72
PMID 32696042
ParticipantIDs pubmed_primary_32696042
PublicationCentury 2000
PublicationDate 2021-Jan-01
PublicationDateYYYYMMDD 2021-01-01
PublicationDate_xml – month: 01
  year: 2021
  text: 2021-Jan-01
  day: 01
PublicationDecade 2020
PublicationPlace United States
PublicationPlace_xml – name: United States
PublicationTitle Journal of biomechanical engineering
PublicationTitleAlternate J Biomech Eng
PublicationYear 2021
SSID ssj0011840
Score 2.443367
Snippet Computational models of the human neck have been developed to assess human response in impact scenarios; however, the assessment and validation of such models...
SourceID pubmed
SourceType Index Database
Title Multilevel Validation of a Male Neck Finite Element Model With Active Musculature
URI https://www.ncbi.nlm.nih.gov/pubmed/32696042
Volume 143
hasFullText
inHoldings 1
isFullTextHit
isPrint
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnZ1LS8NAEMcXqyD1IL7fsgdvIbXZbPM4SrEUoYLYijeZZDcg1lakXvz0zuxumlAqPi4hZGkI-0sns7Mz_2HsgkTdBATCV0kCvlSh9kFpXPN0dAqAn9A4p3rnwW3UH8mbx85j2eLeVZfMslb-ubSu5D9U8RpypSrZP5Cd3xQv4DnyxSMSxuOvGJvq2TGl_XgP6E-rufsH3gANP1qw_MXrPZNb6V3bPHHT_GyMxoB2a4yt8wYfJhm11BZZ4qqaGn0qETZEdSVhWMVB3112hqsMq5o5d0l815q2D0CP9r4eZxBBLc6gnW0UiZ-kTh-2NJ5WZKn-liwxyqRfEbQkKQHZHis1OG-vhg66kaQTI34eXdDHLocarBHH1LzjluI1bh-J1q9OTwqf4nL-DE22Xv5uYT1h_IrhFtt0s8yvLN1ttqInO2yjJhO5w9apfyo15cPTgcuF2GV3FX1e0efTggMn-pzoc0ufO_rc0OdEn1v6vEZ_j41618Nu33cNMnzAld7MhywIQxWSAI-k0BC0o6RIddQupJa6I1IViwxd-Fx1cNUuAYIs0uh_alnIREEs9tnqZDrRh4yLHHRBZcpBVNDecJaGiuqmoR0kEIbRETuws_T0ZlVQnsr5O_525IQ1qxfplK0V-LfTZ-jDzbJzg-kLUYVEnw
linkProvider National Library of Medicine
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Multilevel+Validation+of+a+Male+Neck+Finite+Element+Model+With+Active+Musculature&rft.jtitle=Journal+of+biomechanical+engineering&rft.au=Barker%2C+Jeffrey+B&rft.au=Cronin%2C+Duane+S&rft.date=2021-01-01&rft.eissn=1528-8951&rft.volume=143&rft.issue=1&rft_id=info:doi/10.1115%2F1.4047866&rft_id=info%3Apmid%2F32696042&rft_id=info%3Apmid%2F32696042&rft.externalDocID=32696042