M14 - backflow prevention and cross-connection control : recommended practices
"The purpose of this manual is to educate and inform interested backflow prevention and cross-connection control program managers and administrators about the most current practices; to explore advantages and disadvantages of various policies regarding backflow prevention programs; and to provi...
Saved in:
| Other Authors | |
|---|---|
| Format | Electronic eBook |
| Language | English |
| Published |
Denver, CO :
American Water Works Association,
[2024]
|
| Edition | Fifth edition. |
| Subjects | |
| Online Access | Full text |
| ISBN | 9781613006412 1613006411 9781647171087 |
| Physical Description | 1 online resource |
Cover
| LEADER | 00000cam a22000008i 4500 | ||
|---|---|---|---|
| 001 | kn-on1377817754 | ||
| 003 | OCoLC | ||
| 005 | 20240717213016.0 | ||
| 006 | m o d | ||
| 007 | cr cn||||||||| | ||
| 008 | 230421s2024 cou ob 001 0 eng | ||
| 040 | |a DLC |b eng |e rda |c DLC | ||
| 020 | |a 9781613006412 |q (adobe pdf) | ||
| 020 | |a 1613006411 | ||
| 020 | |z 9781647171087 |q (paperback) | ||
| 035 | |a (OCoLC)1377817754 | ||
| 042 | |a pcc | ||
| 130 | 0 | |a Recommended practices for backflow prevention and cross-connection control. | |
| 245 | 1 | 0 | |a M14 - backflow prevention and cross-connection control : |b recommended practices / |c [edited] by Mitch LeBas. |
| 246 | 3 | 0 | |a Backflow prevention and cross-connection control : |b recommended practices |
| 250 | |a Fifth edition. | ||
| 264 | 1 | |a Denver, CO : |b American Water Works Association, |c [2024] | |
| 300 | |a 1 online resource | ||
| 336 | |a text |b txt |2 rdacontent | ||
| 337 | |a computer |b c |2 rdamedia | ||
| 338 | |a online resource |b cr |2 rdacarrier | ||
| 504 | |a Includes bibliographical references and index. | ||
| 506 | |a Plný text je dostupný pouze z IP adres počítačů Univerzity Tomáše Bati ve Zlíně nebo vzdáleným přístupem pro zaměstnance a studenty | ||
| 520 | |a "The purpose of this manual is to educate and inform interested backflow prevention and cross-connection control program managers and administrators about the most current practices; to explore advantages and disadvantages of various policies regarding backflow prevention programs; and to provide thoughtful and meaningful topics for consideration when developing, implementing, and managing programs"-- |c Provided by publisher. | ||
| 590 | |a Knovel |b Knovel (All titles) | ||
| 650 | 0 | |a Backsiphonage (Plumbing) |x Prevention. | |
| 650 | 0 | |a Cross-connections (Plumbing) | |
| 655 | 7 | |a elektronické knihy |7 fd186907 |2 czenas | |
| 655 | 9 | |a electronic books |2 eczenas | |
| 700 | 1 | |a LeBas, Mitch, |e editor. | |
| 776 | 0 | 8 | |i Print version: |a Recommended practices for backflow prevention and cross-connection control |t M14 - backflow prevention and cross-connection control |b Fifth edition. |d Denver, CO : American Water Works Association, [2023] |z 9781647171087 |w (DLC) 2023018351 |
| 856 | 4 | 0 | |u https://proxy.k.utb.cz/login?url=https://app.knovel.com/hotlink/toc/id:kpBPCCCR02/backflow-prevention-and?kpromoter=marc |y Full text |