Thermal guidelines for data processing environments.

"Covers equipment operating environment guidelines for air-cooled equipment, environmental guidelines for liquid-cooled equipment, facility temperature and humidity measurement, equipment placement and airflow patterns, equipment manufacturers' heat load and airflow requirements reporting,...

Full description

Saved in:
Bibliographic Details
Corporate Author: ASHRAE (Firm), (Author)
Format: eBook
Language: English
Published: Peachtree Corners, GA : ASHRAE, [2021]
Edition: Fifth edition.
Series: ASHRAE datacom series ; book 1
Subjects:
ISBN: 9781947192652
1947192655
9781947192645
1947192647
Physical Description: 1 online resource (x, 156 pages) : illustrations

Cover

Table of contents

LEADER 02346cam a2200457 i 4500
001 kn-on1284926100
003 OCoLC
005 20240717213016.0
006 m o d
007 cr cn|||||||||
008 211109s2021 gau ob 000 0 eng d
040 |a N$T  |b eng  |e rda  |e pn  |c N$T  |d N$T  |d OCLCF  |d OCLCO  |d OCLCQ  |d OCLCO  |d OCLCQ  |d OCLCO  |d NUI  |d COA 
020 |a 9781947192652  |q (electronic bk.) 
020 |a 1947192655  |q (electronic bk.) 
020 |z 9781947192645 
020 |a 1947192647 
020 |a 9781947192645 
024 8 |a (WaSeSS)ssj0002551229 
035 |a (OCoLC)1284926100  |z (OCoLC)1340063364 
245 0 0 |a Thermal guidelines for data processing environments. 
250 |a Fifth edition. 
264 1 |a Peachtree Corners, GA :  |b ASHRAE,  |c [2021] 
300 |a 1 online resource (x, 156 pages) :  |b illustrations 
336 |a text  |b txt  |2 rdacontent 
337 |a computer  |b c  |2 rdamedia 
338 |a online resource  |b cr  |2 rdacarrier 
490 0 |a ASHRAE datacom series ;  |v book 1 
504 |a Includes bibliographical references. 
506 |a Plný text je dostupný pouze z IP adres počítačů Univerzity Tomáše Bati ve Zlíně nebo vzdáleným přístupem pro zaměstnance a studenty 
520 |a "Covers equipment operating environment guidelines for air-cooled equipment, environmental guidelines for liquid-cooled equipment, facility temperature and humidity measurement, equipment placement and airflow patterns, equipment manufacturers' heat load and airflow requirements reporting, and methods for increasing energy efficiency and avoiding electrostatic discharge"--  |c Provided by publisher 
590 |a Knovel  |b Knovel (All titles) 
650 0 |a Data processing service centers  |x Cooling. 
650 0 |a Data processing service centers  |x Heating and ventilation. 
650 0 |a Buildings  |x Environmental engineering. 
650 0 |a Data processing service centers  |x Design and construction. 
650 0 |a Electronic data processing departments  |x Equipment and supplies  |x Protection. 
650 0 |a Electronic apparatus and appliances  |x Cooling. 
655 7 |a elektronické knihy  |7 fd186907  |2 czenas 
655 9 |a electronic books  |2 eczenas 
710 2 |a ASHRAE (Firm),  |e author. 
856 4 0 |u https://proxy.k.utb.cz/login?url=https://app.knovel.com/hotlink/toc/id:kpTGDPEE11/thermal-guidelines-for?kpromoter=marc  |y Full text