Nuclear service water piping : the Salem Nuclear Generating Station of the Public Service Electric & Gas Company, New Jersey, U.S.A.
The Salem Nuclear Generating Station is located in the state of New Jersey on the east coast of the United States of America. It has two 1,100 MW operating units which went into service in 1977 and 1981. Despite regular inspection and maintenance of its service water system, both units began experie...
Saved in:
Corporate Author: | |
---|---|
Format: | eBook |
Language: | English |
Published: |
Toronto, Ont. :
Nickel Institute,
1995.
|
Series: | Case study (Nickel Development Institute (Canada)) ;
no. 15001, 1994. |
Subjects: | |
ISBN: | 9781523131723 1523131721 |
Physical Description: | 1 online resource (4 pages) : illustrations |
LEADER | 02344cam a2200373 i 4500 | ||
---|---|---|---|
001 | kn-on1256731086 | ||
003 | OCoLC | ||
005 | 20240717213016.0 | ||
006 | m o d | ||
007 | cr cn||||||||| | ||
008 | 210616s1995 onca o 000 0 eng d | ||
040 | |a HUA |b eng |e rda |e pn |c HUA |d OCLCO |d OCLCF |d OCLCO |d VLB |d OCLCO | ||
020 | |a 9781523131723 |q (electronic bk.) | ||
020 | |a 1523131721 |q (electronic bk.) | ||
035 | |a (OCoLC)1256731086 | ||
245 | 0 | 0 | |a Nuclear service water piping : |b the Salem Nuclear Generating Station of the Public Service Electric & Gas Company, New Jersey, U.S.A. |
264 | 1 | |a Toronto, Ont. : |b Nickel Institute, |c 1995. | |
300 | |a 1 online resource (4 pages) : |b illustrations | ||
336 | |a text |b txt |2 rdacontent | ||
337 | |a computer |b c |2 rdamedia | ||
338 | |a online resource |b cr |2 rdacarrier | ||
490 | 1 | |a NiDI case study ; |v no. 15001, 1994 | |
506 | |a Plný text je dostupný pouze z IP adres počítačů Univerzity Tomáše Bati ve Zlíně nebo vzdáleným přístupem pro zaměstnance a studenty | ||
520 | |a The Salem Nuclear Generating Station is located in the state of New Jersey on the east coast of the United States of America. It has two 1,100 MW operating units which went into service in 1977 and 1981. Despite regular inspection and maintenance of its service water system, both units began experiencing numerous problems with corrosion of the in-plant service water piping. This led the utility to thoroughly evaluate the problem and possible replacement materials and to conduct an extensive testing program. The results obtained from both the testing program and the plant's service experience with the various replacement materials are described in this case study. | ||
590 | |a Knovel |b Knovel (All titles) | ||
610 | 2 | 0 | |a Salem Nuclear Power Plant (N.J.) |
610 | 2 | 7 | |a Salem Nuclear Power Plant (N.J.) |2 fast |0 (OCoLC)fst01916700 |
650 | 0 | |a Nuclear power plants |x Piping. | |
655 | 7 | |a elektronické knihy |7 fd186907 |2 czenas | |
655 | 9 | |a electronic books |2 eczenas | |
710 | 2 | |a Nickel Institute. | |
776 | 0 | 8 | |i Print version: |t Nuclear service water piping |
830 | 0 | |a Case study (Nickel Development Institute (Canada)) ; |v no. 15001, 1994. | |
856 | 4 | 0 | |u https://proxy.k.utb.cz/login?url=https://app.knovel.com/hotlink/toc/id:kpNSWPTSN1/nuclear-service-water?kpromoter=marc |y Full text |