Power transformer condition monitoring and diagnosis

The following topics are dealt with: power transformer; condition monitoring; dissolved gas analysis; partial discharges; moisture analysis; paper; thermal ageing and mechanical oscillations.

Saved in:
Bibliographic Details
Other Authors: Abu-Siada, Ahmed, (Editor)
Format: eBook
Language: English
Published: London : Institution of Engineering and Technology, 2018.
Series: IET energy engineering series ; 104.
Subjects:
ISBN: 9781785612558
1785612557
9781523121045
1523121041
9781785612541
1785612549
Physical Description: 1 online resource (xix, 304 pages) : illustrations

Cover

Table of contents

LEADER 05176cam a2200505 i 4500
001 kn-on1043671012
003 OCoLC
005 20240717213016.0
006 m o d
007 cr cn|||||||||
008 180709t20182018enka ob 001 0 eng d
040 |a UAB  |b eng  |e rda  |e pn  |c UAB  |d UAB  |d LGG  |d UIU  |d OCLCF  |d CDN  |d OTZ  |d STF  |d EBLCP  |d OCL  |d U3G  |d YDX  |d CUS  |d MERUC  |d CUV  |d UKAHL  |d KNOVL  |d N$T  |d OCLCQ  |d OCLCO  |d OCLCQ  |d OCLCO  |d OCLCQ  |d OCLCO  |d BRX  |d SXB 
020 |a 9781785612558  |q (electronic bk.) 
020 |a 1785612557  |q (electronic bk.) 
020 |a 9781523121045  |q (electronic bk.) 
020 |a 1523121041  |q (electronic bk.) 
020 |z 9781785612541 
020 |z 1785612549 
035 |a (OCoLC)1043671012  |z (OCoLC)1057432947 
245 0 0 |a Power transformer condition monitoring and diagnosis /  |c edited by Ahmed Abu-Siada. 
264 1 |a London :  |b Institution of Engineering and Technology,  |c 2018. 
264 4 |c ©2018 
300 |a 1 online resource (xix, 304 pages) :  |b illustrations 
336 |a text  |b txt  |2 rdacontent 
337 |a computer  |b c  |2 rdamedia 
338 |a online resource  |b cr  |2 rdacarrier 
490 1 |a IET Energy Engineering ;  |v 104 
504 |a Includes bibliographical references and index. 
506 |a Plný text je dostupný pouze z IP adres počítačů Univerzity Tomáše Bati ve Zlíně nebo vzdáleným přístupem pro zaměstnance a studenty 
520 |a The following topics are dealt with: power transformer; condition monitoring; dissolved gas analysis; partial discharges; moisture analysis; paper; thermal ageing and mechanical oscillations. 
505 0 |a Intro; Contents; About the editor; Preface; List of acronyms; 1. Dissolved gas analysis, measurements and interpretations -- Carlos Gamez; 1.1 Introduction; 1.2 Insulating liquids; 1.2.1 Mineral oil; 1.3 The transformer as a chemical reactor; 1.3.1 Gas production mechanisms; 1.4 Oil analysis; 1.4.1 Gas chromatography; 1.5 Oil sampling; 1.5.1 Bottle sampling; 1.5.2 Syringe sampling; 1.6 Interpretation techniques; 1.6.1 Fault types; 1.6.2 Techniques that rely on the gas profile; 1.6.3 Techniques that rely on ratios; 1.6.4 Techniques that rely on rates of change; 1.6.5 Putting it all together 
505 8 |a 1.7 Future of oil analysis1.7.1 Online monitors; 1.7.2 Larger datasets; 1.7.3 Analysis automation; References; 2. Partial discharges: keys for condition monitoring and diagnosis of power transformers -- Ricardo Albarracıń, Guillermo Robles, Jorge Alfredo Ardila-Rey, Andrea Cavallini and Renzo Passaglia; Abstract; 2.1 Introduction; 2.2 Dielectric materials used in power transformers; 2.3 Effects of ageing in insulation systems of power transformers; 2.3.1 Thermal stress; 2.3.2 Mechanical stress; 2.3.3 Electrical stress; 2.3.4 Ambient stress 
505 8 |a 2.4 Condition monitoring techniques in power transformers2.4.1 Electrical measurements; 2.4.2 Apparent charge estimation: quasi-integration and calibration; 2.4.3 PD detection in transformers; 2.4.4 Unconventional methods of partial discharge measurements in power transformers; 2.4.5 Methods of partial discharge analysis; 2.5 Conclusions; Acknowledgements; References; 3. Moisture analysis for power transformers -- Beleń Garcıá, Alexander Ceśpedes and Diego Garcıá; 3.1 Introduction; 3.2 Moisture in transformer insulation 
505 8 |a 3.2.1 Risks associated to the presence of high levels of moisture in transformers3.2.2 Sources of moisture contamination in transformers; 3.3 Moisture dynamics in transformers; 3.3.1 Adsorption and desorption of moisture in cellulosic insulation; 3.3.2 Moisture distribution within transformer solid insulation; 3.3.3 Solubility of water in oil; 3.3.4 Moisture equilibrium between paper and oil; 3.3.5 Moisture equilibrium in alternative fluids; 3.3.6 Moisture dynamics in a transformer under operation; 3.4 Monitoring of moisture content in oil; 3.4.1 Periodical sampling of oil 
505 8 |a 3.4.2 On-line measure of oil moisture with capacitive sensors3.4.3 Interpretation of the moisture content of oil; 3.5 Estimation of the moisture content of solid insulation from moisture in oil measures; 3.5.1 Determination of moisture content of paper using the equilibrium charts; 3.5.2 Improved methodologies to estimate the moisture content of paper from the measures of moisture content of oil; 3.6 Dielectric response methods for the estimation of moisture in solid insulation; 3.6.1 Theoretical principles; 3.6.2 Frequency dielectric spectroscopy; 3.6.3 Recovery voltage method 
590 |a Knovel  |b Knovel (All titles) 
630 0 7 |a Monitoring  |2 fast 
650 0 |a Electric transformers  |x Testing. 
650 0 |a Electric discharges. 
655 7 |a elektronické knihy  |7 fd186907  |2 czenas 
655 9 |a electronic books  |2 eczenas 
700 1 |a Abu-Siada, Ahmed,  |e editor. 
776 0 8 |i Print version:  |t Power transformer condition monitoring and diagnosis.  |d London : Institution of Engineering and Technology, 2018  |z 9781785612541  |w (OCoLC)1045058025 
830 0 |a IET energy engineering series ;  |v 104. 
856 4 0 |u https://proxy.k.utb.cz/login?url=https://app.knovel.com/hotlink/toc/id:kpPTCMD00B/power-transformer-condition?kpromoter=marc  |y Full text