Limits of detection in chemical analysis
Details methods for computing valid limits of detection.-Clearly explains analytical detection limit theory, thereby mitigating incorrect detection limit concepts, methodologies and results -Extensive use of computer simulations that are freely available to readers -Curated short-list of important r...
Saved in:
Main Author: | |
---|---|
Format: | eBook |
Language: | English |
Published: |
Hoboken, NJ :
John Wiley & Sons,
2017.
|
Series: | Chemical analysis ;
v. 185. |
Subjects: | |
ISBN: | 9781523114948 1523114940 9781119188971 1119188970 9781119188988 1119188989 9781119188995 1119188997 9781119189008 1119189004 |
Physical Description: | 1 online resource |
LEADER | 03942cam a2200505 i 4500 | ||
---|---|---|---|
001 | kn-ocn971615718 | ||
003 | OCoLC | ||
005 | 20240717213016.0 | ||
006 | m o d | ||
007 | cr cn||||||||| | ||
008 | 170206s2017 nju ob 001 0 eng | ||
040 | |a DLC |b eng |e rda |e pn |c DLC |d N$T |d IDEBK |d YDX |d DG1 |d UIU |d OCLCF |d UPM |d MERUC |d DEBSZ |d VGM |d OTZ |d VLB |d OCLCO |d W2U |d OCLCQ |d EBLCP |d MERER |d OCLCQ |d DEBBG |d OCLCQ |d KNOVL |d KSU |d STF |d NLE |d INT |d AU@ |d CEF |d ERL |d UKMGB |d UWO |d RECBK |d LVT |d LOA |d U3W |d ICG |d U3G |d COCUF |d VT2 |d DKC |d ZCU |d K6U |d OCLCQ |d UKAHL |d UX1 |d DLC |d S9I |d ERF |d UKBTH |d UHL |d NJT |d NLW |d OCLCQ |d SFB |d UAB |d UKCRE |d MM9 |d LUN |d N9V |d SDF |d S2H |d EUN |d REDDC |d HS0 |d OCL |d OCLCO |d N$T |d OCLCQ |d OCLCO |d OCLCQ |d OCLCO |d SXB |d OCLCQ |d OCLCO | ||
020 | |a 9781523114948 |q (electronic bk.) | ||
020 | |a 1523114940 |q (electronic bk.) | ||
020 | |a 9781119188971 |q (electronic bk.) | ||
020 | |a 1119188970 |q (electronic bk.) | ||
020 | |z 9781119188988 | ||
020 | |z 1119188989 | ||
020 | |z 9781119188995 | ||
020 | |z 1119188997 | ||
020 | |z 9781119189008 | ||
020 | |z 1119189004 | ||
020 | |z 1119188970 | ||
024 | 8 | |a 13528625 | |
035 | |a (OCoLC)971615718 |z (OCoLC)975224226 |z (OCoLC)1088953737 |z (OCoLC)1100437529 |z (OCoLC)1104667209 |z (OCoLC)1124371032 |z (OCoLC)1148160280 | ||
042 | |a pcc | ||
100 | 1 | |a Voigtman, Edward, |d 1949- |e author. |1 https://id.oclc.org/worldcat/entity/E39PCjvMB7GbJ4PMXPDFx4HY8y | |
245 | 1 | 0 | |a Limits of detection in chemical analysis / |c Edward Voigtman. |
264 | 1 | |a Hoboken, NJ : |b John Wiley & Sons, |c 2017. | |
300 | |a 1 online resource | ||
336 | |a text |b txt |2 rdacontent | ||
337 | |a computer |b c |2 rdamedia | ||
338 | |a online resource |b cr |2 rdacarrier | ||
490 | 1 | |a Chemical analysis : a series of monographs on analytical chemistry and its applications ; |v volume 185 | |
504 | |a Includes bibliographical references and index. | ||
506 | |a Plný text je dostupný pouze z IP adres počítačů Univerzity Tomáše Bati ve Zlíně nebo vzdáleným přístupem pro zaměstnance a studenty | ||
520 | |a Details methods for computing valid limits of detection.-Clearly explains analytical detection limit theory, thereby mitigating incorrect detection limit concepts, methodologies and results -Extensive use of computer simulations that are freely available to readers -Curated short-list of important references for limits of detection -Videos, screencasts, and animations are provided at an associated website, to enhance understanding -Illustrated, with many detailed examples and cogent explanations. | ||
505 | 0 | |a Background -- Chemical measurement systems and their errors -- The response, net response and content domains -- Traditional limits of detection -- Modern limits of detection -- Receiver operating characteristics -- Statistics of an ideal model CMS -- If only the true intercept is unknown -- If only the true slope is unknown -- If the true intercept and true slope are both unknown -- If only the population standard deviation is unknown -- If only the true slope is known -- If only the true intercept is known -- If all three parameters are unknown -- Bootstrapped detection limits in a real CMS -- Four relevant considerations -- Neyman-Pearson hypothesis testing -- Heteroscedastic noises -- Limits of quantitation -- The sampled step function -- The sampled rectangular pulse -- The sampled triangular pulse -- The sampled Gaussian pulse -- Parting considerations. | |
590 | |a Knovel |b Knovel (All titles) | ||
650 | 0 | |a Analytical chemistry. | |
655 | 7 | |a elektronické knihy |7 fd186907 |2 czenas | |
655 | 9 | |a electronic books |2 eczenas | |
776 | 0 | 8 | |i Print version: |a Voigtman, Edward, 1949- |t Limits of detection in chemical analysis. |d Hoboken, NJ : John Wiley & Sons, 2017 |z 9781119188971 |w (DLC) 2017000471 |
830 | 0 | |a Chemical analysis ; |v v. 185. | |
856 | 4 | 0 | |u https://proxy.k.utb.cz/login?url=https://app.knovel.com/hotlink/toc/id:kpLDCA0001/limits-of-detection?kpromoter=marc |y Full text |