Boiler water treatment principles and practice : charts and notes for field use
Table of Contents: About the Author - Saturated steam temperatures at various boiler pressures - Boiler Energy and Power Units - Typical gross heating values of common fuels (based on approximately 80% fuel to steam efficiency) - Typical energy consumption and output ratings for a fire tube boiler -...
Saved in:
Main Author: | |
---|---|
Format: | eBook |
Language: | English |
Published: |
[New York?] :
Chemical Publishing Company, Inc.,
2013.
|
Edition: | First edition. |
Subjects: | |
ISBN: | 9781523102723 1523102721 082060173X 9780820601731 |
Physical Description: | 1 online resource (vi, 56 pages) |
LEADER | 05542cam a2200409 i 4500 | ||
---|---|---|---|
001 | kn-ocn953706335 | ||
003 | OCoLC | ||
005 | 20240717213016.0 | ||
006 | m o d | ||
007 | cr cn||||||||| | ||
008 | 160719s2013 nyu o 000 0 eng d | ||
040 | |a SINTU |b eng |e rda |e pn |c SINTU |d KNOVL |d COO |d STF |d OCLCQ |d S4S |d VT2 |d OCLCQ |d RRP |d WYU |d AU@ |d OCLCQ |d OCLCO |d OCLCQ |d OCLCO |d OCLCL |d SXB | ||
020 | |a 9781523102723 |q (electronic bk.) | ||
020 | |a 1523102721 |q (electronic bk.) | ||
020 | |a 082060173X | ||
020 | |a 9780820601731 | ||
020 | |z 082060173X | ||
020 | |z 9780820601731 | ||
024 | 3 | |a 9780820601731 | |
035 | |a (OCoLC)953706335 |z (OCoLC)960707478 |z (OCoLC)961884883 |z (OCoLC)1096660363 | ||
100 | 1 | |a Frayne, Colin. | |
245 | 1 | 0 | |a Boiler water treatment principles and practice : |b charts and notes for field use / |c Colin Frayne. |
250 | |a First edition. | ||
264 | 1 | |a [New York?] : |b Chemical Publishing Company, Inc., |c 2013. | |
300 | |a 1 online resource (vi, 56 pages) | ||
336 | |a text |b txt |2 rdacontent | ||
337 | |a computer |b c |2 rdamedia | ||
338 | |a online resource |b cr |2 rdacarrier | ||
506 | |a Plný text je dostupný pouze z IP adres počítačů Univerzity Tomáše Bati ve Zlíně nebo vzdáleným přístupem pro zaměstnance a studenty | ||
520 | 8 | |a Table of Contents: About the Author - Saturated steam temperatures at various boiler pressures - Boiler Energy and Power Units - Typical gross heating values of common fuels (based on approximately 80% fuel to steam efficiency) - Typical energy consumption and output ratings for a fire tube boiler - Steam tables suitable for pressure deaerators - Calculating Blowdown - Coefficients of thermal conductivity for some heat-exchanger metals and boiler deposits - Types of water or steam commonly employed in most HW heating and steam generating plants - Commonly occurring minerals in natural MU water sources - Specific waterside / steamside problems affecting MPHW and HPHW boiler plants - Salt concentration indicators - Summary of waterside / steamside problems affecting LPHW and LP steam heating boiler plants - FW contamination from MU water - FW contamination from returned condensate - Problems associated with the final FW blend - Deposition of boiler section waterside surfaces by alkaline earth metal salts, other inorganic salts and organics - Silica and silicate crystalline scales and deposits affecting boiler section waterside surfaces - Iron oxide and other boiler section corrosion debris deposits - Boiler section corrosion problems involving oxygen, concentration cells and low pH - Stress and high temperature related corrosion - Steam purity, quality and other operational problems - Specification for grades of high-quality water suitable for higher pressure WT boilers - Practical considerations for a RW ion-exchange softener - Types of Internal Treatment Program - Carbonate Cycle Requirement Calculations - Phosphate-Cycle Requirement Calculations - A Guide to Tannin Residuals in BW - Carbonate-Cycle Program. BW Carbonate Reserve Requirements by Pressure and Sulfate Concentration - Carbonate-Cycle Coagulation and Precipitation Program. Recommended BW Control Limits for Non-Highly-Rated FT Boilers Employing Hard or Partially Softened FW - Phosphate-Cycle Coagulation and Precipitation Program. Recommended BW Control Limits for Non-Highly-Rated FT Boilers Employing Hard, Partially Softened, or Fully Softened FW - Phosphate-Cycle Coagulation and Precipitation Program. Recommended BW Control Limits for Non-Highly-Rated WT Boilers Employing Hard, Partially Softened, or Fully Softened FW - Chelant demand (ppm product) per 1ppm substrate EDTA Chelant or All-Polymer/All-Organic Program. Recommended BW Control Limits for Fired WT Boilers Employing Demineralized or Similar Quality FW - Oxygen Solubility at Atmospheric Pressure - Properties of Oxygen Scavengers - Carbon Dioxide Evolution from FW Alkalinity - Amine Requirement to Reach a Stable Condensate pH - Amine Basicity Dissociation Constants - Neutralizing Amine Summary Notes - Some DR values for CO2, NH3 and neutralizing amines at various pressures - Calculating Alkalinity Feed-Rate Requirements - ASME Consensus table 1: Suggested water chemistry limits. Industrial watertube, high duty, primary fuel fired, drum typeMakeup water percentage: Up to 100% of feedwater. Conditions: Includes superheater, turbine drives or process restriction on steam purity] - ASME Consensus table 2: Suggested chemistry limits. Industrial watertube, high duty, primary fuel fired, drum type] - ASME Consensus table 3: Suggested chemistry limits. Industrial firetube, high duty, primary fuel fired] - ASME Consensus table 4: Suggested water chemistry limits. Industrial coil type, watertube, high duty, primary fuel fired rapid steam generators] - ASME Consensus table 5: Suggested water chemistry limits. Marine propulsion, watertube, oil fired drum type] - ASME Consensus table 6: Suggested water chemistry limits. Electrode, high voltage, forced circulation jet type] - Notes. | |
590 | |a Knovel |b Knovel (All titles) | ||
650 | 0 | |a Feed-water purification. | |
650 | 0 | |a Boilers |x Water-supply. | |
655 | 7 | |a elektronické knihy |7 fd186907 |2 czenas | |
655 | 9 | |a electronic books |2 eczenas | |
776 | 0 | 8 | |i Print version: |a Frayne, Colin. |t Boiler water treatment principles and practice. |b First edition |z 082060173X |w (OCoLC)853649292 |
856 | 4 | 0 | |u https://proxy.k.utb.cz/login?url=https://app.knovel.com/hotlink/toc/id:kpBWTPPCNO/boiler-water-treatment?kpromoter=marc |y Full text |