Boiler water treatment principles and practice : charts and notes for field use

Table of Contents: About the Author - Saturated steam temperatures at various boiler pressures - Boiler Energy and Power Units - Typical gross heating values of common fuels (based on approximately 80% fuel to steam efficiency) - Typical energy consumption and output ratings for a fire tube boiler -...

Full description

Saved in:
Bibliographic Details
Main Author: Frayne, Colin.
Format: eBook
Language: English
Published: [New York?] : Chemical Publishing Company, Inc., 2013.
Edition: First edition.
Subjects:
ISBN: 9781523102723
1523102721
082060173X
9780820601731
Physical Description: 1 online resource (vi, 56 pages)

Cover

Table of contents

LEADER 05542cam a2200409 i 4500
001 kn-ocn953706335
003 OCoLC
005 20240717213016.0
006 m o d
007 cr cn|||||||||
008 160719s2013 nyu o 000 0 eng d
040 |a SINTU  |b eng  |e rda  |e pn  |c SINTU  |d KNOVL  |d COO  |d STF  |d OCLCQ  |d S4S  |d VT2  |d OCLCQ  |d RRP  |d WYU  |d AU@  |d OCLCQ  |d OCLCO  |d OCLCQ  |d OCLCO  |d OCLCL  |d SXB 
020 |a 9781523102723  |q (electronic bk.) 
020 |a 1523102721  |q (electronic bk.) 
020 |a 082060173X 
020 |a 9780820601731 
020 |z 082060173X 
020 |z 9780820601731 
024 3 |a 9780820601731 
035 |a (OCoLC)953706335  |z (OCoLC)960707478  |z (OCoLC)961884883  |z (OCoLC)1096660363 
100 1 |a Frayne, Colin. 
245 1 0 |a Boiler water treatment principles and practice :  |b charts and notes for field use /  |c Colin Frayne. 
250 |a First edition. 
264 1 |a [New York?] :  |b Chemical Publishing Company, Inc.,  |c 2013. 
300 |a 1 online resource (vi, 56 pages) 
336 |a text  |b txt  |2 rdacontent 
337 |a computer  |b c  |2 rdamedia 
338 |a online resource  |b cr  |2 rdacarrier 
506 |a Plný text je dostupný pouze z IP adres počítačů Univerzity Tomáše Bati ve Zlíně nebo vzdáleným přístupem pro zaměstnance a studenty 
520 8 |a Table of Contents: About the Author - Saturated steam temperatures at various boiler pressures - Boiler Energy and Power Units - Typical gross heating values of common fuels (based on approximately 80% fuel to steam efficiency) - Typical energy consumption and output ratings for a fire tube boiler - Steam tables suitable for pressure deaerators - Calculating Blowdown - Coefficients of thermal conductivity for some heat-exchanger metals and boiler deposits - Types of water or steam commonly employed in most HW heating and steam generating plants - Commonly occurring minerals in natural MU water sources - Specific waterside / steamside problems affecting MPHW and HPHW boiler plants - Salt concentration indicators - Summary of waterside / steamside problems affecting LPHW and LP steam heating boiler plants - FW contamination from MU water - FW contamination from returned condensate - Problems associated with the final FW blend - Deposition of boiler section waterside surfaces by alkaline earth metal salts, other inorganic salts and organics - Silica and silicate crystalline scales and deposits affecting boiler section waterside surfaces - Iron oxide and other boiler section corrosion debris deposits - Boiler section corrosion problems involving oxygen, concentration cells and low pH - Stress and high temperature related corrosion - Steam purity, quality and other operational problems - Specification for grades of high-quality water suitable for higher pressure WT boilers - Practical considerations for a RW ion-exchange softener - Types of Internal Treatment Program - Carbonate Cycle Requirement Calculations - Phosphate-Cycle Requirement Calculations - A Guide to Tannin Residuals in BW - Carbonate-Cycle Program. BW Carbonate Reserve Requirements by Pressure and Sulfate Concentration - Carbonate-Cycle Coagulation and Precipitation Program. Recommended BW Control Limits for Non-Highly-Rated FT Boilers Employing Hard or Partially Softened FW - Phosphate-Cycle Coagulation and Precipitation Program. Recommended BW Control Limits for Non-Highly-Rated FT Boilers Employing Hard, Partially Softened, or Fully Softened FW - Phosphate-Cycle Coagulation and Precipitation Program. Recommended BW Control Limits for Non-Highly-Rated WT Boilers Employing Hard, Partially Softened, or Fully Softened FW - Chelant demand (ppm product) per 1ppm substrate EDTA Chelant or All-Polymer/All-Organic Program. Recommended BW Control Limits for Fired WT Boilers Employing Demineralized or Similar Quality FW - Oxygen Solubility at Atmospheric Pressure - Properties of Oxygen Scavengers - Carbon Dioxide Evolution from FW Alkalinity - Amine Requirement to Reach a Stable Condensate pH - Amine Basicity Dissociation Constants - Neutralizing Amine Summary Notes - Some DR values for CO2, NH3 and neutralizing amines at various pressures - Calculating Alkalinity Feed-Rate Requirements - ASME Consensus table 1: Suggested water chemistry limits. Industrial watertube, high duty, primary fuel fired, drum typeMakeup water percentage: Up to 100% of feedwater. Conditions: Includes superheater, turbine drives or process restriction on steam purity] - ASME Consensus table 2: Suggested chemistry limits. Industrial watertube, high duty, primary fuel fired, drum type] - ASME Consensus table 3: Suggested chemistry limits. Industrial firetube, high duty, primary fuel fired] - ASME Consensus table 4: Suggested water chemistry limits. Industrial coil type, watertube, high duty, primary fuel fired rapid steam generators] - ASME Consensus table 5: Suggested water chemistry limits. Marine propulsion, watertube, oil fired drum type] - ASME Consensus table 6: Suggested water chemistry limits. Electrode, high voltage, forced circulation jet type] - Notes. 
590 |a Knovel  |b Knovel (All titles) 
650 0 |a Feed-water purification. 
650 0 |a Boilers  |x Water-supply. 
655 7 |a elektronické knihy  |7 fd186907  |2 czenas 
655 9 |a electronic books  |2 eczenas 
776 0 8 |i Print version:  |a Frayne, Colin.  |t Boiler water treatment principles and practice.  |b First edition  |z 082060173X  |w (OCoLC)853649292 
856 4 0 |u https://proxy.k.utb.cz/login?url=https://app.knovel.com/hotlink/toc/id:kpBWTPPCNO/boiler-water-treatment?kpromoter=marc  |y Full text