Inspection of air conditioning systems

CIBSE TM44 is used as the guidance for air conditioning inspections in the UK, the Republic of Ireland, Malta and Gibraltar. The guidance is primarily intended to support inspections which are carried out for compliance with the EPBD, but will also be useful to anyone who wishes to assess the energy...

Full description

Saved in:
Bibliographic Details
Main Author: Hitchin, Roger.
Corporate Author: Chartered Institution of Building Services Engineers.
Other Authors: Butcher, Ken.
Format: eBook
Language: English
Published: London : CIBSE, [2012]
Edition: Second edition, 2012 edition.
Series: CIBSE ; TM44 : 2012.
Subjects:
ISBN: 9781680150223
1680150227
9781906846206
1906846200
Physical Description: 1 online resource (29 pages)

Cover

Table of contents

LEADER 04472cam a2200469 i 4500
001 kn-ocn890596758
003 OCoLC
005 20240717213016.0
006 m o d
007 cr cn|||||||||
008 140915s2012 enk ob 000 0 eng d
040 |a KNOVL  |b eng  |e rda  |e pn  |c KNOVL  |d COO  |d ZCU  |d OCLCQ  |d STF  |d OCLCQ  |d OCLCF  |d GILDS  |d CEF  |d RRP  |d OCLCQ  |d YOU  |d OCLCQ  |d OCLCO  |d HNC  |d OCLCQ  |d OCLCO  |d SXB 
020 |a 9781680150223  |q (electronic bk.) 
020 |a 1680150227  |q (electronic bk.) 
020 |z 9781906846206 
020 |z 1906846200 
035 |a (OCoLC)890596758 
100 1 |a Hitchin, Roger. 
245 1 0 |a Inspection of air conditioning systems /  |c [principal author, Roger Hitchin ; editor, Ken Butcher]. 
250 |a Second edition, 2012 edition. 
264 1 |a London :  |b CIBSE,  |c [2012] 
264 4 |c ©2012 
300 |a 1 online resource (29 pages) 
336 |a text  |b txt  |2 rdacontent 
337 |a computer  |b c  |2 rdamedia 
338 |a online resource  |b cr  |2 rdacarrier 
490 1 |a CIBSE ;  |v TM44 : 2012 
504 |a Includes bibliographical references. 
505 0 0 |g 1.  |t Introduction:  |t Purpose of air conditioning inspections ; Purpose of this technical memorandum ; Regulatory applications ; Scope ; Health and safety issues --  |g 2.  |t The inspection process:  |t Issues common to all systems ; Packaged cooling systems: simple procedure ; Centralised cooling systems: full procedure --  |g 3.  |t Assessing system efficiency and sizing:  |t Efficiency ; Sixing ; Assessment of ventilation performance --  |g 4.  |t Factors relating to the provision of advice:  |t Factors affecting air conditioning energy consumption ; Cooling load reduction ; Free cooling via condensers ; Absorption cooling with CHP --  |g 5.  |t Other sources of information:  |t European standards ; European research results ; European implementation lessons. 
506 |a Plný text je dostupný pouze z IP adres počítačů Univerzity Tomáše Bati ve Zlíně nebo vzdáleným přístupem pro zaměstnance a studenty 
520 8 |a CIBSE TM44 is used as the guidance for air conditioning inspections in the UK, the Republic of Ireland, Malta and Gibraltar. The guidance is primarily intended to support inspections which are carried out for compliance with the EPBD, but will also be useful to anyone who wishes to assess the energy effi ciency of an air conditioning system. With the benefit of the experience gained over the past three years, and to clarify some of the questions about air conditioning system inspections that have arisen over that period, the TM has been revised. The revision also takes into account the reporting templates produced by the Department for Communities and Local Government for the production of reports in England and Wales. These templates will also form the basis for statutory lodgement of air conditioning inspection reports, which will be required in England and Wales as from 6th April 2012 under amendments to the Energy Performance of Buildings Regulations 2007. The revision has also provided the opportunity to incorporate the separate legislative requirements for Northern Ireland and Scotland in the main text of the TM, rather than as separate addenda. TM44 provides guidance on conducting an air conditioning inspection to satisfy the requirements of the Directive as expressed in the various regulations in the UK. The focus is on systems that use refrigerants to produce cooling. Some of the guidance may also be applicable to elements of other forms of cooling systems, such as those that use pipes or ducts built into the fabric of the building (e.g. cooled deck or ceiling slabs), or those which use aquifers or local water sources to provide cooling solutions. TM44: 2007 is superseded by this new edition. 
590 |a Knovel  |b Knovel (All titles) 
650 0 |a Air conditioning  |x Inspection. 
650 0 |a Air conditioning  |x Safety regulations. 
650 0 |a Air conditioning  |x Equipment and supplies  |x Maintenance and repair. 
655 7 |a elektronické knihy  |7 fd186907  |2 czenas 
655 9 |a electronic books  |2 eczenas 
700 1 |a Butcher, Ken. 
710 2 |a Chartered Institution of Building Services Engineers. 
776 0 8 |i Print version:  |a Hitchin, Roger.  |t Inspection of air conditioning systems.  |b Second edition, 2012 edition  |z 9781906846206  |w (OCoLC)793079905 
830 0 |a CIBSE ;  |v TM44 : 2012. 
856 4 0 |u https://proxy.k.utb.cz/login?url=https://app.knovel.com/hotlink/toc/id:kpIACSAGE1/inspection-of-air?kpromoter=marc  |y Full text