Vapour cloud development in over-filling incidents
Describes an assessment method for calculating the rate at which the volume of a vapour cloud increases during an overfilling incident. The assessment also gives the concentration of hydrocarbons in the cloud and provides some guidance on the extent of cloud spread in relatively flat sites with the...
Saved in:
Corporate Authors: | , |
---|---|
Format: | eBook |
Language: | English |
Published: |
[Acton, Eng.] :
Steel Construction Institute,
©2013.
|
Series: | FABIG technical note ;
12 |
Subjects: | |
ISBN: | 9781621987000 1621987000 |
Physical Description: | 1 online resource. |
LEADER | 03017cam a2200421 a 4500 | ||
---|---|---|---|
001 | kn-ocn849903239 | ||
003 | OCoLC | ||
005 | 20240717213016.0 | ||
006 | m o d | ||
007 | cr cn||||||||| | ||
008 | 130624s2013 enk ob 000 0 eng d | ||
040 | |a KNOVL |b eng |e pn |c KNOVL |d KNOVL |d OCLCQ |d ZCU |d OCLCQ |d OCLCF |d CEF |d RRP |d K6U |d OCLCO |d OCLCQ |d OCLCO |d OCLCQ |d SXB | ||
020 | |a 9781621987000 |q (electronic bk.) | ||
020 | |a 1621987000 |q (electronic bk.) | ||
035 | |a (OCoLC)849903239 | ||
110 | 2 | |a Steel Construction Institute (Great Britain). |b Fire and Blast Information Group. | |
245 | 1 | 0 | |a Vapour cloud development in over-filling incidents / |c Fire and Blast Information Group. |
260 | |a [Acton, Eng.] : |b Steel Construction Institute, |c ©2013. | ||
300 | |a 1 online resource. | ||
336 | |a text |b txt |2 rdacontent | ||
337 | |a computer |b c |2 rdamedia | ||
338 | |a online resource |b cr |2 rdacarrier | ||
490 | 1 | |a FABIG technical note ; |v 12 | |
500 | |a Cover title. | ||
500 | |a "April 2013." | ||
504 | |a Includes bibliographical references. | ||
506 | |a Plný text je dostupný pouze z IP adres počítačů Univerzity Tomáše Bati ve Zlíně nebo vzdáleným přístupem pro zaměstnance a studenty | ||
520 | |a Describes an assessment method for calculating the rate at which the volume of a vapour cloud increases during an overfilling incident. The assessment also gives the concentration of hydrocarbons in the cloud and provides some guidance on the extent of cloud spread in relatively flat sites with the kind of obstructions that would be normal in and around a fuel depot tank farm. This Technical Note allows vapour cloud assessment for an overfill of a range of fuels and solvents that are commonly stored in large volumes. Substance/mixture specific equilibrium thermodynamic analysis of air/liquid mixtures in humid atmospheres has been conducted and an empirical correlation and constants are provided that will allow the vapour concentration at the foot of the overfill cascade to be predicted. Whilst the HSE VCA method was developed for vapour cloud development resulting from overfills in calm conditions, this Technical Note gives some preliminary guidance on extending the assessment to low (non-zero) wind speeds and to calculating the rate at which a cloud may accumulate in the case of spray releases (e.g. flange failure or pipe rupture). | ||
590 | |a Knovel |b Knovel (All titles) | ||
650 | 0 | |a Gasoline |x Storage. | |
650 | 0 | |a Gasoline vapor control. | |
650 | 0 | |a Flammable gases. | |
650 | 0 | |a Gasoline industry |x Equipment and supplies. | |
655 | 7 | |a elektronické knihy |7 fd186907 |2 czenas | |
655 | 9 | |a electronic books |2 eczenas | |
710 | 2 | |a Steel Construction Institute (Great Britain) | |
810 | 2 | |a Steel Construction Institute (Great Britain). |b Fire and Blast Information Group. |t FABIG technical note ; |v 12. | |
856 | 4 | 0 | |u https://proxy.k.utb.cz/login?url=https://app.knovel.com/hotlink/toc/id:kpVCDOFIF1/vapour-cloud-development?kpromoter=marc |y Full text |