Liquid cooling guidelines for datacom equipment centers.
Saved in:
| Corporate Author | |
|---|---|
| Format | Electronic eBook |
| Language | English |
| Published |
Atlanta, Georgia :
American Society of Heating, Refrigerating and Air-Conditioning Engineers,
©2006.
|
| Series | ASHRAE datacom series.
|
| Subjects | |
| Online Access | Full text |
| ISBN | 9781461923053 1461923050 9781680153248 1680153242 9781933742052 1933742054 |
| Physical Description | 1 online resource (viii, 92 pages) : illustrations (some color) |
Cover
| LEADER | 00000cam a2200000 i 4500 | ||
|---|---|---|---|
| 001 | kn-ocn831680341 | ||
| 003 | OCoLC | ||
| 005 | 20240717213016.0 | ||
| 006 | m o d | ||
| 007 | cr cn||||||||| | ||
| 008 | 130325s2006 gaua ob 001 0 eng d | ||
| 040 | |a TFW |b eng |e rda |e pn |c TFW |d N$T |d B24X7 |d COO |d OCLCO |d KNOVL |d VLB |d YDXCP |d OCLCQ |d ZCU |d OCLCQ |d STF |d VT2 |d OCLCQ |d JBG |d OCLCQ |d LIV |d K6U |d REB |d OCLCF |d RRP |d AU@ |d WYU |d YOU |d OCLCQ |d MM9 |d SFB |d OCLCO |d HNC |d OCLCQ |d OCLCO |d OCLCL |d OCLCQ | ||
| 020 | |a 9781461923053 |q (electronic bk.) | ||
| 020 | |a 1461923050 |q (electronic bk.) | ||
| 020 | |a 9781680153248 |q (electronic bk.) | ||
| 020 | |a 1680153242 |q (electronic bk.) | ||
| 020 | |z 9781933742052 | ||
| 020 | |z 1933742054 | ||
| 035 | |a (OCoLC)831680341 |z (OCoLC)961847035 |z (OCoLC)988716973 |z (OCoLC)999580884 |z (OCoLC)1026431343 |z (OCoLC)1066453633 |z (OCoLC)1136270677 |z (OCoLC)1167430343 |z (OCoLC)1180728043 | ||
| 245 | 0 | 0 | |a Liquid cooling guidelines for datacom equipment centers. |
| 264 | 1 | |a Atlanta, Georgia : |b American Society of Heating, Refrigerating and Air-Conditioning Engineers, |c ©2006. | |
| 300 | |a 1 online resource (viii, 92 pages) : |b illustrations (some color) | ||
| 336 | |a text |b txt |2 rdacontent | ||
| 337 | |a computer |b c |2 rdamedia | ||
| 338 | |a online resource |b cr |2 rdacarrier | ||
| 490 | 1 | |a ASHRAE datacom series | |
| 504 | |a Includes bibliographical references (pages 79-80) and index. | ||
| 505 | 0 | |a Machine derived contents note: Contents -- Acknowledgments xx -- Chapter 1 Introduction xx -- 1.1 Definitions xx -- 1.2 Liquid Cooling Systems xx -- Chapter 2 Facility Cooling Systems xx -- 2.1 Introduction xx -- 2.2 Equipment xx -- 2.3 Heat Rejection Equipment xx -- 2.4 Pumps xx -- 2.5 Energy Recovery Equipment xx -- Chapter 3 Facility Piping Design xx -- 3.1 General xx -- 3.2 Spatial xx -- 3.3 Basic Piping Arrangements for the Cooling Plant xx -- 3.4 Piping Arrangements for the Cooling Plant xx -- 3.5 Water Treatment Issues xx -- 3.6 Earthquake Protection xx -- Chapter 4 Liquid Cooling Implementation for -- Datacom Equipment xx -- 4.1 Overview of Liquid-Cooled Racks and Cabinets xx -- 4.2 Overview of Air- and Liquid-Cooled Datacom Equipment xx -- 4.3 Overview of Coolant Distribution Unit xx -- Chapter 5 Liquid Cooling Infrastructure Requirements -- for Chilled-Water Systems xx -- 5.1 Building Facility Chilled-Water Systems xx -- 5.2 Nonchilled Water Facility Systems xx -- Chapter 6 Liquid Cooling Infrastructure Requirements for -- Technology Cooling Systems xx -- 6.1 Water-Based Technology Cooling System xx -- 6.2 Nonwater-Based Technology Cooling System xx -- References and Bibliography xx -- Glossary of Terms xx -- Appendix xx -- Index xx. | |
| 506 | |a Plný text je dostupný pouze z IP adres počítačů Univerzity Tomáše Bati ve Zlíně nebo vzdáleným přístupem pro zaměstnance a studenty | ||
| 590 | |a Knovel |b Knovel (All titles) | ||
| 650 | 0 | |a Data processing service centers |x Cooling. | |
| 650 | 0 | |a Electronic data processing departments |x Equipment and supplies |x Protection. | |
| 650 | 0 | |a Hydronics. | |
| 650 | 0 | |a Electronic apparatus and appliances |x Cooling. | |
| 650 | 0 | |a Electronic digital computers |x Cooling. | |
| 650 | 0 | |a Buildings |x Environmental engineering. | |
| 655 | 7 | |a elektronické knihy |7 fd186907 |2 czenas | |
| 655 | 9 | |a electronic books |2 eczenas | |
| 710 | 2 | |a American Society of Heating, Refrigerating and Air-Conditioning Engineers. | |
| 776 | 0 | 8 | |i Print version: |t Liquid cooling guidelines for datacom equipment centers. |d Atlanta, GA : American Society of Heating, Refrigerating and Air-Conditioning Engineers, ©2006 |w (DLC) 2006026115 |
| 830 | 0 | |a ASHRAE datacom series. | |
| 856 | 4 | 0 | |u https://proxy.k.utb.cz/login?url=https://app.knovel.com/hotlink/toc/id:kpLCGDEC04/liquid-cooling-guidelines?kpromoter=marc |y Full text |