Thermal guidelines for data processing environments.

"This third edition of Thermal Guidelines for Data Processing Environments breaks new ground through the addition of new data center classes enabling near full-time use of free cooling techniques in the vast majority of the world's climates"--

Saved in:
Bibliographic Details
Corporate Author: American Society of Heating, Refrigerating and Air-Conditioning Engineers.
Format: eBook
Language: English
Published: Atlanta, GA : ASHRAE, 2012.
Edition: 3rd ed.
Series: ASHRAE datacom series ; bk. 1.
Subjects:
ISBN: 9781936504367
1936504367
9781621988144
1621988147
9781936504336
1936504332
Physical Description: 1 online resource (vii, 136 pages) : illustrations

Cover

Table of contents

LEADER 02757cam a2200493 a 4500
001 kn-ocn829904330
003 OCoLC
005 20240717213016.0
006 m o d
007 cr cn|||||||||
008 130313s2012 gaua ob 000 0 eng d
040 |a N$T  |b eng  |e pn  |c N$T  |d YDXCP  |d KNOVL  |d B24X7  |d ZCU  |d KNOVL  |d OCLCQ  |d VT2  |d AGLDB  |d LIV  |d K6U  |d OCLCF  |d JBG  |d OCLCQ  |d VTS  |d RRP  |d AU@  |d COO  |d WYU  |d YOU  |d STF  |d M8D  |d OCLCQ  |d MM9  |d UWW  |d OCLCQ  |d OCLCO  |d OCLCQ  |d OCLCO  |d SXB 
020 |a 9781936504367  |q (electronic bk.) 
020 |a 1936504367  |q (electronic bk.) 
020 |a 9781621988144  |q (electronic bk.) 
020 |a 1621988147  |q (electronic bk.) 
020 |z 9781936504336 
020 |z 1936504332 
020 |z 1936504367 
035 |a (OCoLC)829904330  |z (OCoLC)961885266  |z (OCoLC)988616218  |z (OCoLC)999409244  |z (OCoLC)1058132213  |z (OCoLC)1065701013  |z (OCoLC)1086965153  |z (OCoLC)1097129611 
245 0 0 |a Thermal guidelines for data processing environments. 
250 |a 3rd ed. 
260 |a Atlanta, GA :  |b ASHRAE,  |c 2012. 
300 |a 1 online resource (vii, 136 pages) :  |b illustrations 
336 |a text  |b txt  |2 rdacontent 
337 |a computer  |b c  |2 rdamedia 
338 |a online resource  |b cr  |2 rdacarrier 
490 1 |a ASHRAE datacom series ;  |v bk. 1 
504 |a Includes bibliographical references (pages 133-136). 
506 |a Plný text je dostupný pouze z IP adres počítačů Univerzity Tomáše Bati ve Zlíně nebo vzdáleným přístupem pro zaměstnance a studenty 
520 |a "This third edition of Thermal Guidelines for Data Processing Environments breaks new ground through the addition of new data center classes enabling near full-time use of free cooling techniques in the vast majority of the world's climates"--  |c Provided by publisher 
590 |a Knovel  |b Knovel (All titles) 
650 0 |a Data processing service centers  |x Cooling. 
650 0 |a Data processing service centers  |x Heating and ventilation. 
650 0 |a Buildings  |x Environmental engineering. 
650 0 |a Data processing service centers  |x Design and construction. 
650 0 |a Electronic data processing departments  |x Equipment and supplies  |x Protection. 
650 0 |a Electronic apparatus and appliances  |x Cooling. 
655 7 |a elektronické knihy  |7 fd186907  |2 czenas 
655 9 |a electronic books  |2 eczenas 
710 2 |a American Society of Heating, Refrigerating and Air-Conditioning Engineers. 
776 0 8 |i Print version:  |t Thermal guidelines for data processing environments.  |b 3rd ed.  |d Atlanta, GA : ASHRAE, 2012  |z 9781936504336  |w (DLC) 2012029220  |w (OCoLC)804491202 
830 0 |a ASHRAE datacom series ;  |v bk. 1. 
856 4 0 |u https://proxy.k.utb.cz/login?url=https://app.knovel.com/hotlink/toc/id:kpTGDPEE01/thermal-guidelines-for?kpromoter=marc  |y Full text