Reliable design of medical devices
As medical devices become even more intricate, concerns about efficacy, safety, and reliability continue to be raised. Users and patients both want the device to operate as specified, perform in a safe manner, and continue to perform over a long period of time without failure. Following in the foots...
Saved in:
Main Author: | |
---|---|
Format: | eBook |
Language: | English |
Published: |
Boca Raton :
CRC Press,
2013.
|
Edition: | 3rd ed. |
Subjects: | |
ISBN: | 9781439894941 1439894949 9781439894910 1439894914 9781138075191 1138075191 |
Physical Description: | 1 online resource (xxix, 471 pages) : illustrations |
LEADER | 03094cam a2200445 a 4500 | ||
---|---|---|---|
001 | kn-ocn809041656 | ||
003 | OCoLC | ||
005 | 20240717213016.0 | ||
006 | m o d | ||
007 | cr cn||||||||| | ||
008 | 120904s2013 flua ob 001 0 eng d | ||
040 | |a N$T |b eng |e pn |c N$T |d YDXCP |d OCLCQ |d UAB |d OCLCQ |d MYG |d UIU |d OCLCF |d E7B |d MMU |d GZM |d CAUOI |d UKMGB |d CRCPR |d EBLCP |d DEBSZ |d OCLCQ |d OCLCO |d OCLCQ |d VGM |d OCLCQ |d YUS |d NLE |d AU@ |d WYU |d OCLCA |d LVT |d UKAHL |d OCLCQ |d LEAUB |d ESU |d OCLCQ |d CUV |d OCLCO |d OCLCQ |d SFB |d OCLCQ |d OCLCO |d OCLCL |d OCLCQ | ||
020 | |a 9781439894941 |q (electronic bk.) | ||
020 | |a 1439894949 |q (electronic bk.) | ||
020 | |z 9781439894910 | ||
020 | |z 1439894914 | ||
020 | |z 9781138075191 |q (paperback) | ||
020 | |z 1138075191 |q (paperback) | ||
035 | |a (OCoLC)809041656 |z (OCoLC)815509872 |z (OCoLC)848789705 |z (OCoLC)899155134 |z (OCoLC)1058937149 |z (OCoLC)1066452470 |z (OCoLC)1076633510 |z (OCoLC)1086420220 |z (OCoLC)1097096396 | ||
100 | 1 | |a Fries, Richard C. | |
245 | 1 | 0 | |a Reliable design of medical devices / |c Richard C. Fries. |
250 | |a 3rd ed. | ||
260 | |a Boca Raton : |b CRC Press, |c 2013. | ||
300 | |a 1 online resource (xxix, 471 pages) : |b illustrations | ||
336 | |a text |b txt |2 rdacontent | ||
337 | |a computer |b c |2 rdamedia | ||
338 | |a online resource |b cr |2 rdacarrier | ||
506 | |a Plný text je dostupný pouze z IP adres počítačů Univerzity Tomáše Bati ve Zlíně nebo vzdáleným přístupem pro zaměstnance a studenty | ||
520 | |a As medical devices become even more intricate, concerns about efficacy, safety, and reliability continue to be raised. Users and patients both want the device to operate as specified, perform in a safe manner, and continue to perform over a long period of time without failure. Following in the footsteps of the bestselling second edition, Reliable Design of Medical Devices, Third Edition shows you how to improve reliability in the design of advanced medical devices. Reliability engineering is an integral part of the product development process and of problem-solving activities related to manufa. | ||
504 | |a Includes bibliographical references and index. | ||
505 | 0 | |a pt. 1. The basics of reliability -- pt. 2. The concept phase -- pt. 3. The feasibility phase -- pt. 4. The design phase -- pt. 5. Verification and validation -- pt. 6. Design transfer and manufacturing -- pt. 7. Field activity. | |
590 | |a Knovel |b Knovel (All titles) | ||
650 | 0 | |a Medical instruments and apparatus |x Reliability. | |
650 | 0 | |a Medical instruments and apparatus |x Design and construction. | |
650 | 0 | |a Medical instruments and apparatus |x Quality control. | |
650 | 0 | |a Medical instruments and apparatus |x Standards. | |
655 | 7 | |a elektronické knihy |7 fd186907 |2 czenas | |
655 | 9 | |a electronic books |2 eczenas | |
776 | 0 | 8 | |i Print version: |a Fries, Richard C. |t Reliable design of medical devices. |b 3rd ed. |d Boca Raton : CRC Press, 2013 |z 9781439894910 |w (DLC) 2012015405 |w (OCoLC)786161795 |
856 | 4 | 0 | |u https://proxy.k.utb.cz/login?url=https://app.knovel.com/hotlink/toc/id:kpRDMDE001/reliable-design-of?kpromoter=marc |y Full text |