Design guide for stainless steel blast walls

"Stainless steel blast walls made from profiled sheeting are commonly used on offshore process platforms where there is a risk of accidental gas explosions. They are usually required to survive the explosion in order to protect personnel and safety critical equipment and to prevent the spread o...

Full description

Saved in:
Bibliographic Details
Corporate Authors: Steel Construction Institute (Great Britain). Fire and Blast Information Group., Steel Construction Institute (Great Britain)
Format: eBook
Language: English
Published: [Ascot, Eng.] : Steel Construction Institute, 1999.
Series: FABIG technical note ; 5
Subjects:
ISBN: 9781613447406
161344740X
Physical Description: 1 online resource (119 pages).

Cover

Table of contents

LEADER 03634cam a2200481Mi 4500
001 kn-ocn794372352
003 OCoLC
005 20240717213016.0
006 m o d
007 cr cn|||||||||
008 120524s1999 enk o 000 0 eng
040 |a AU@  |b eng  |e pn  |c AU@  |d KNOVL  |d OCLCO  |d OCLCQ  |d KNOVL  |d OCLCO  |d KNOVL  |d OCLCQ  |d RIC  |d OCLCO  |d OCLCQ  |d BUF  |d OCLCF  |d CEF  |d RRP  |d WYU  |d OCLCO  |d OCLCQ  |d OCLCO  |d SXB 
020 |a 9781613447406  |q (electronic bk.) 
020 |a 161344740X  |q (electronic bk.) 
035 |a (OCoLC)794372352  |z (OCoLC)896403755 
110 2 |a Steel Construction Institute (Great Britain).  |b Fire and Blast Information Group. 
245 1 0 |a Design guide for stainless steel blast walls /  |c Fire and Blast Information Group. 
246 3 0 |a Interim guidance notes for the design and protection of topside structures against explosion and fire 
260 |a [Ascot, Eng.] :  |b Steel Construction Institute,  |c 1999. 
300 |a 1 online resource (119 pages). 
336 |a text  |b txt  |2 rdacontent 
337 |a computer  |b c  |2 rdamedia 
338 |a online resource  |b cr  |2 rdacarrier 
490 1 |a FABIG technical note ;  |v 5 
500 |a "FABIG Technical Note - June 1999." 
500 |a At head of title: Technical note and worked examples to supplement the Interim guidance notes for the design and protection of topside structures against explosion and fire. 
500 |a "The Technical Note is based on work carried out by Mr R. Brewerton, acting as a Consultant to The Steel Construction Institute." 
506 |a Plný text je dostupný pouze z IP adres počítačů Univerzity Tomáše Bati ve Zlíně nebo vzdáleným přístupem pro zaměstnance a studenty 
520 |a "Stainless steel blast walls made from profiled sheeting are commonly used on offshore process platforms where there is a risk of accidental gas explosions. They are usually required to survive the explosion in order to protect personnel and safety critical equipment and to prevent the spread of possible subsequent fire. They can also be used in onshore process plant and in other situations where protection from explosions is a requirement. This document gives guidance on the design of stainless steel blast walls made from profiled sheeting, including guidance on material behavior and selection, response to blast loading, design for longitudinal and transverse bending effects, evaluation of plastic deformation capacity and recommendations on construction details. The document specifically addresses walls constructed of panels with simple trapezoidal corrugations with or without longitudinal flange stiffeners manufactured from the grades of wrought stainless steel which are widely used in offshore structural applications."--Knovel. 
590 |a Knovel  |b Knovel (All titles) 
650 0 |a Blast effect. 
650 0 |a Stainless steel sheets. 
650 0 |a Offshore structures  |x Design and construction. 
650 0 |a Offshore structures  |x Fires and fire prevention. 
650 0 |a Drilling platforms  |x Design and construction. 
650 0 |a Drilling platforms  |x Fires and fire prevention. 
650 0 |a Steel, Structural  |x Effect of high temperatures on. 
650 0 |a Steel, Structural  |x Effect of explosion on. 
655 7 |a elektronické knihy  |7 fd186907  |2 czenas 
655 9 |a electronic books  |2 eczenas 
710 2 |a Steel Construction Institute (Great Britain) 
810 2 |a Steel Construction Institute (Great Britain).  |b Fire and Blast Information Group.  |t FABIG technical note ;  |v 5. 
856 4 0 |u https://proxy.k.utb.cz/login?url=https://app.knovel.com/hotlink/toc/id:kpDGSSBWF1/design-guide-for?kpromoter=marc  |y Full text