Uncertainties in internal radiation dose assessment.
Saved in:
Corporate Author: | |
---|---|
Format: | eBook |
Language: | English |
Published: |
Bethesda, Md. :
National Council on Radiation Protection and Measurements,
2010.
|
Series: | NCRP report ;
no. 164. |
Subjects: | |
ISBN: | 9781615838943 1615838945 9781441680013 1441680012 9780982384329 0982384327 |
Physical Description: | 1 online resource (xxii, 841 pages). |
LEADER | 04997cam a2200469 a 4500 | ||
---|---|---|---|
001 | kn-ocn713833434 | ||
003 | OCoLC | ||
005 | 20240717213016.0 | ||
006 | m o d | ||
007 | cr cn||||||||| | ||
008 | 110421s2010 mdu ob f000 0 eng d | ||
040 | |a KNOVL |b eng |e pn |c KNOVL |d OCLCQ |d OCLCO |d OCLCQ |d KNOVL |d ZCU |d KNOVL |d OCLCF |d KNOVL |d N$T |d E7B |d YDXCP |d OCLCQ |d EBLCP |d DEBSZ |d OCLCQ |d STF |d OCLCQ |d CEF |d WYU |d OCLCQ |d UX1 |d OCLCO |d OCLCQ |d OCLCO |d OCLCQ |d SXB | ||
020 | |a 9781615838943 |q (electronic bk.) | ||
020 | |a 1615838945 |q (electronic bk.) | ||
020 | |a 9781441680013 |q (electronic bk.) | ||
020 | |a 1441680012 |q (electronic bk.) | ||
020 | |z 9780982384329 | ||
020 | |z 0982384327 | ||
035 | |a (OCoLC)713833434 |z (OCoLC)694097404 |z (OCoLC)923311497 |z (OCoLC)1065831262 |z (OCoLC)1152021095 | ||
245 | 0 | 0 | |a Uncertainties in internal radiation dose assessment. |
260 | |a Bethesda, Md. : |b National Council on Radiation Protection and Measurements, |c 2010. | ||
300 | |a 1 online resource (xxii, 841 pages). | ||
336 | |a text |b txt |2 rdacontent | ||
337 | |a computer |b c |2 rdamedia | ||
338 | |a online resource |b cr |2 rdacarrier | ||
490 | 1 | |a NCRP report ; |v no. 164 | |
504 | |a Includes bibliographical references (pages 751-821). | ||
505 | 0 | |a ""Cover""; ""Preface""; ""Contents""; ""1. Executive Summary""; ""1.1 Methods Used to Determine Doses from Internal Irradiation""; ""1.2 Types and Categories of Uncertainties""; ""1.3 Uncertainties in the Measurements""; ""1.4 Uncertainties in the Intakes""; ""1.5 Uncertainties in the Biokinetic and Dosimetric Model Structure and Parameters""; ""1.6 Statistical Methods Used to Evaluate Uncertainties in Internal Dose Assessments""; ""1.7 Application, Results and Examples""; ""2. Introduction""; ""2.1 Intended Use""; ""2.2 Scope of Report""; ""2.3 Organization and Contents of this Report"" | |
505 | 8 | |a ""3. Methods Used to Determine Doses from Internal Irradiation""""3.1 General Methods for Dose Calculations""; ""3.1.1 Intake Models""; ""3.1.2 Systemic Models""; ""3.1.3 Dosimetric Models""; ""3.2 Assessing Dose for Specific versus Unspecified Individuals in Retrospective and Prospective Dose Assessments""; ""3.2.1 Specific versus Unspecified Individuals""; ""3.2.2 Retrospective versus Prospective Assessments""; ""3.3 Implementation of the InternalDose Assessment Methods""; ""3.3.1 Using Models and Measurements to Derive Intakes"" | |
505 | 8 | |a ""3.3.2 Assessment of Doses in the Occupational, Environmental and Medical Settings""""4. Sources, Types and Categories of Uncertainties""; ""4.1 Introduction""; ""4.2 Sources of Uncertainty in Internal Dosimetry""; ""4.2.1 Uncertainties in Measurements""; ""4.2.2 Sources of Uncertainty Related to the Characteristics of the Intake""; ""4.2.3 Uncertainties in Biokinetic and Dosimetric Models""; ""4.3 Distinguishing Aleatory and Epistemic Uncertainties""; ""4.4 Classical or Berkson Uncertainty Models""; ""4.4.1 Definition of Classical and Berkson Models"" | |
505 | 8 | |a ""4.4.2 Classical and Berkson Errors in the Context of Internal-Dosimetry Models""""4.5 Biases and Systematic Errors""; ""4.6 Examples of Application of Different Types of Uncertainty""; ""4.6.1 Example No. 1: Dose to a Group of 14 y Old Individuals, Measured Thyroid Masses""; ""4.6.2 Example No. 2: Dose to a Group of 14 y Old Individuals, Thyroid Mass from Literature""; ""4.6.3 Example No. 3: Dose to a Group of 14 y Old Individuals, Multiple Sources of Uncertainty""; ""4.7 Evaluation and Expression of Uncertainties""; ""5. Statistical Methods for Evaluating Uncertainties"" | |
505 | 8 | |a ""5.1 Introduction""""5.2 Propagation of Uncertainties for Problems Without Measurement Data""; ""5.2.1 Monte-Carlo Methods""; ""5.2.2 Goiânia Accident Example""; ""5.2.3 Results""; ""5.3 Methods Based on Bayes� Theorem""; ""5.3.1 Examples""; ""5.3.2 Application of MCMC to a Problem with Bioassay Data""; ""5.3.3 Methods for Obtaining Prior Distributions""; ""5.3.4 Bayesian Hypothesis Testing""; ""5.3.5 Advantages and Criticisms of the Bayesian Approach""; ""5.4 Classical Methods""; ""5.4.1 Introduction""; ""5.4.2 Formulation of the Problem""; ""5.4.3 Possible Solutions to the Problem"" | |
506 | |a Plný text je dostupný pouze z IP adres počítačů Univerzity Tomáše Bati ve Zlíně nebo vzdáleným přístupem pro zaměstnance a studenty | ||
590 | |a Knovel |b Knovel (All titles) | ||
650 | 0 | |a Radiation dosimetry. | |
650 | 0 | |a Radiation |x Dosage. | |
655 | 7 | |a elektronické knihy |7 fd186907 |2 czenas | |
655 | 9 | |a electronic books |2 eczenas | |
710 | 2 | |a National Council on Radiation Protection and Measurements. | |
776 | 0 | 8 | |i Print version: |t Uncertainties in internal radiation dose assessment. |d Bethesda, Md. : National Council on Radiation Protection and Measurements, 2010 |z 9780982384329 |
830 | 0 | |a NCRP report ; |v no. 164. | |
856 | 4 | 0 | |u https://proxy.k.utb.cz/login?url=https://app.knovel.com/hotlink/toc/id:kpUIRDARN1/uncertainties-in-internal?kpromoter=marc |y Full text |