Recommended practice for backflow prevention and cross-connection control
Saved in:
| Corporate Author | |
|---|---|
| Format | Electronic eBook |
| Language | English |
| Published |
Denver, Colorado (U.S.A.) :
American Water Works Association,
©2004.
|
| Edition | Third edition. |
| Series | AWWA manual ;
M14. |
| Subjects | |
| Online Access | Full text |
| ISBN | 9781615837830 1615837833 9781583212882 1583212884 |
| Physical Description | 1 online resource (x, 134 pages) : illustrations. |
Cover
| LEADER | 00000cam a2200000 i 4500 | ||
|---|---|---|---|
| 001 | kn-ocn701918734 | ||
| 003 | OCoLC | ||
| 005 | 20240717213016.0 | ||
| 006 | m o d | ||
| 007 | cr cn||||||||| | ||
| 008 | 110215s2004 coua ob 001 0 eng d | ||
| 040 | |a KNOVL |b eng |e rda |e pn |c KNOVL |d OCLCQ |d DEBSZ |d GA0 |d OCLCQ |d E7B |d OCLCO |d OCLCQ |d KNOVL |d ZCU |d KNOVL |d OCLCF |d KNOVL |d OCLCE |d CNNAI |d OCLCQ |d VT2 |d COO |d OCLCA |d BUF |d CEF |d RRP |d AU@ |d OCLCQ |d WYU |d YOU |d UX1 |d UAB |d OCLCO |d OCLCQ |d HNC |d COA |d OCLCO |d OCLCQ |d SXB | ||
| 020 | |a 9781615837830 |q (electronic bk.) | ||
| 020 | |a 1615837833 |q (electronic bk.) | ||
| 020 | |a 9781583212882 | ||
| 020 | |a 1583212884 | ||
| 024 | 8 | |a (WaSeSS)ssj0000509383 | |
| 035 | |a (OCoLC)701918734 |z (OCoLC)607582081 |z (OCoLC)648086735 |z (OCoLC)858444359 |z (OCoLC)961887768 |z (OCoLC)987027361 |z (OCoLC)988635470 |z (OCoLC)988713270 |z (OCoLC)993556581 |z (OCoLC)999509269 |z (OCoLC)1002899928 |z (OCoLC)1044295886 |z (OCoLC)1047743785 |z (OCoLC)1055403248 |z (OCoLC)1056418149 |z (OCoLC)1058014477 |z (OCoLC)1060888944 |z (OCoLC)1065901073 |z (OCoLC)1074235941 |z (OCoLC)1077875624 |z (OCoLC)1081241873 |z (OCoLC)1087428479 |z (OCoLC)1101712172 |z (OCoLC)1145373692 |z (OCoLC)1153331553 |z (OCoLC)1224451651 |z (OCoLC)1228557167 |z (OCoLC)1229063981 |z (OCoLC)1340094297 |z (OCoLC)1343986797 | ||
| 042 | |a dlr | ||
| 245 | 0 | 0 | |a Recommended practice for backflow prevention and cross-connection control / |c American Water Works Association. |
| 250 | |a Third edition. | ||
| 264 | 1 | |a Denver, Colorado (U.S.A.) : |b American Water Works Association, |c ©2004. | |
| 300 | |a 1 online resource (x, 134 pages) : |b illustrations. | ||
| 336 | |a text |b txt |2 rdacontent | ||
| 337 | |a computer |b c |2 rdamedia | ||
| 338 | |a online resource |b cr |2 rdacarrier | ||
| 490 | 1 | |a AWWA manual ; |v M14 | |
| 504 | |a Includes bibliographical references (page 123) and index. | ||
| 505 | 0 | |a Ch. 1. Introduction -- Ch. 2. Program administration -- Ch. 3. Backflow principles -- Ch. 4. Backflow-prevention assembly application, installation, and maintenance -- Ch. 5. Typical hazards -- App. A. Assembly test procedures -- App. B. Model ordinance -- App. C. Common symbols -- App. D. AWWA policy statement on cross-connections -- App. E. Abbreviations of agencies and organizations -- App. F. Web sites for backflow-prevention incidents. | |
| 506 | |a Plný text je dostupný pouze z IP adres počítačů Univerzity Tomáše Bati ve Zlíně nebo vzdáleným přístupem pro zaměstnance a studenty | ||
| 520 | 1 | |a "AWWA Manual M14, Recommended Practice for Backflow Prevention and Cross-Connection Control, provides guidance to water purveyors on the recommended procedures and practices for operating a cross-connection control program. A cross-connection is an actual or potential connection between any part of a potable water system and any other environment that contains other substances that, under any circumstances, would allow such substances to enter the potable water system. The purpose of any cross-connection control program is to reduce the risk of contamination or pollution of the public water system."--Jacket. | |
| 590 | |a Knovel |b Knovel (All titles) | ||
| 650 | 0 | |a Backsiphonage (Plumbing) |x Prevention. | |
| 650 | 0 | |a Cross-connections (Plumbing) |x Standards. | |
| 655 | 7 | |a elektronické knihy |7 fd186907 |2 czenas | |
| 655 | 9 | |a electronic books |2 eczenas | |
| 710 | 2 | |a American Water Works Association. | |
| 776 | 0 | 8 | |i Print version: |t Recommended practice for backflow prevention and cross-connection control. |b 3rd ed. |d Denver, CO : American Water Works Association, ©2004 |z 1583212884 |w (DLC) 2003063633 |w (OCoLC)53900012 |
| 776 | 0 | 8 | |i Online version: |t Recommended practice for backflow prevention and cross-connection control. |b 3rd ed. |d Denver, CO : American Water Works Association, ©2004 |w (OCoLC)1343986797 |
| 830 | 0 | |a AWWA manual ; |v M14. | |
| 856 | 4 | 0 | |u https://proxy.k.utb.cz/login?url=https://app.knovel.com/hotlink/toc/id:kpRPBPCCC2/recommended-practice-for?kpromoter=marc |y Full text |