Pulsed fast neutron analysis system used in security surveillance.
Saved in:
| Corporate Author | |
|---|---|
| Format | Electronic eBook |
| Language | English |
| Published |
Bethesda, Maryland :
National Council on Radiation Protection and Measurements,
©2003.
|
| Series | NCRP commentary ;
no. 17. |
| Subjects | |
| Online Access | Full text |
| ISBN | 0929600797 9780929600796 9781601194732 1601194730 |
| Physical Description | 1 online resource (vii, 56 pages) : illustrations : digital, HTML and PDF files |
Cover
| LEADER | 00000cam a2200000 a 4500 | ||
|---|---|---|---|
| 001 | kn-ocn194113478 | ||
| 003 | OCoLC | ||
| 005 | 20240717213016.0 | ||
| 006 | m o d | ||
| 007 | cr cn||||||||| | ||
| 008 | 080221s2003 mdua ob 000 0 eng d | ||
| 040 | |a BUF |b eng |e pn |c BUF |d KNOVL |d OCLCQ |d OCLCO |d KNOVL |d ZCU |d KNOVL |d COCUF |d COO |d OCLCE |d DKDLA |d CCO |d E7B |d CN5CF |d KNOVL |d OCLCQ |d EBLCP |d OCLCQ |d STF |d OCLCQ |d OCLCO |d OCLCA |d BUF |d OCLCO |d MERUC |d OCLCO |d BRL |d CEF |d OCL |d AU@ |d OCLCQ |d OCLCO |d WYU |d OCLCA |d OCLCQ |d UKBTH |d UX1 |d UAB |d OCLCO |d OCLCA |d OCLCO |d OCLCQ |d HNC |d OCLCQ |d OCLCO |d SXB | ||
| 020 | |a 0929600797 |q (print) | ||
| 020 | |a 9780929600796 |q (print) | ||
| 020 | |a 9781601194732 |q (electronic book) | ||
| 020 | |a 1601194730 |q (electronic book) | ||
| 035 | |a (OCoLC)194113478 |z (OCoLC)290554486 |z (OCoLC)301376792 |z (OCoLC)468758236 |z (OCoLC)475483178 |z (OCoLC)475661863 |z (OCoLC)568113178 |z (OCoLC)645881230 |z (OCoLC)646752478 |z (OCoLC)755664759 |z (OCoLC)923310124 |z (OCoLC)977637021 |z (OCoLC)1037427726 |z (OCoLC)1044567900 |z (OCoLC)1056420731 |z (OCoLC)1058084309 |z (OCoLC)1060945090 |z (OCoLC)1065829635 |z (OCoLC)1075412477 |z (OCoLC)1113610200 |z (OCoLC)1151930791 |z (OCoLC)1159639734 |z (OCoLC)1229060753 | ||
| 042 | |a dlr | ||
| 245 | 0 | 0 | |a Pulsed fast neutron analysis system used in security surveillance. |
| 264 | 1 | |a Bethesda, Maryland : |b National Council on Radiation Protection and Measurements, |c ©2003. | |
| 300 | |a 1 online resource (vii, 56 pages) : |b illustrations : digital, HTML and PDF files | ||
| 336 | |a text |b txt |2 rdacontent | ||
| 337 | |a computer |b c |2 rdamedia | ||
| 338 | |a online resource |b cr |2 rdacarrier | ||
| 490 | 1 | |a NCRP commentary ; |v no. 17 | |
| 500 | |a "Issued December 22, 2003 Revised August 11, 2004." | ||
| 504 | |a Includes bibliographical references (pages 53-54). | ||
| 505 | 0 | |a ""Cover ""; ""Preface""; ""Contents""; ""1. Summary""; ""1.1 The Appropriate Dose Limit for Persons Inadvertently Irradiated by the Pulsed Fast Neutron Analysis System""; ""1.2 Effective Dose""; ""1.3 Neutron Activation in Pharmaceuticals and Medical Devices""; ""1.4 Applicable Radiation Protection Concepts for Workers and Members of the Public""; ""1.5 The “As Low As Reasonably Achievable� Principle and Its Application to the Pulsed Fast Neutron Analysis Facility""; ""1.6 Advice on the System Safety Specifications and the Radiation Safety Plan"" | |
| 505 | 8 | |a 1.7 Potential Effects on Nuclear Weapons in Scanned Cargo1.8 Approach to Determination of Effective Dose for Inadvertently Exposed Individuals -- 1.9 Determination of Effective Dose for Inadvertently Exposed Individuals -- 1.10 Validation Measurements and Uncertainties -- 1.11 Application of the Results -- 1.12 Quality Control of Pulsed Fast Neutron Analysis System Performance -- 2. The Appropriate Dose Limit for Inadvertently Exposed Individuals and Levels of Activation Products in Pharmaceuticals and Medical Devices -- 2.1 Introduction -- 2.2 The Appropriate Dose Limit | |
| 505 | 8 | |a 2.2.1 Prior NCRP Recommendations2.2.2 Recommendations for the Pulsed Fast Neutron Analysis System -- 2.3 Determination of Effective Dose -- 2.3.1 Dosimetry Approach -- 2.3.2 Effective Dose Formulation -- 2.3.3 Specific Application to Monte Carlo Calculations -- 2.4 Neutron Activation in Pharmaceuticals and Medical Devices -- 2.4.1 Approach to Analysis of Neutron Activation Products -- 2.4.2 Neutron Activation Products for the Pulsed Fast Neutron Analysis System -- 2.4.3 Activation Products in Pharmaceuticals Uniformly Distributed in the Body | |
| 505 | 8 | |a ""2.4.4 Activation Products in Implanted Medical Devices""""2.5 Conclusions""; ""2.5.1 The Appropriate Dose Limit""; ""2.5.2 Determination of Effective Dose""; ""2.5.3 Neutron Activation in Pharmaceuticals and Medical Devices""; ""3. The “As Low As Reasonably Achievable"" Principle and Related Issues""; ""3.1 Introduction""; ""3.2 Description of a Pulsed Fast Neutron Analysis Facility""; ""3.3 Principles of Radiation Protection""; ""3.3.1 Effects of Concern in Radiation Protection""; ""3.3.2 The Radiation Protection System""; ""3.4 “As Low as Reasonably Achievable� Philosophy"" | |
| 505 | 8 | |a ""3.4.1 Application of “As Low As Reasonably Achievable� to the Pulsed Fast Neutron Analysis Facility""""3.4.2 Radiation Levels at the Inspection Station""; ""3.4.3 Doses from Inadvertent Exposure""; ""3.4.4 Activation Products in Food, Pharmaceuticals, Medical Devices, and Other Cargo""; ""3.4.5 Radiation Levels Outside the Facility""; ""3.5 System Safety Specifications""; ""3.6 Radiation Safety Plan""; ""3.6.1 Radiological Area Classifications""; ""3.6.2 Access Controls""; ""3.6.3 Radiation Detection and Monitoring""; ""3.6.4 Interlocks and Emergency Switches""; ""3.6.5 Shielding"" | |
| 506 | |a Plný text je dostupný pouze z IP adres počítačů Univerzity Tomáše Bati ve Zlíně nebo vzdáleným přístupem pro zaměstnance a studenty | ||
| 590 | |a Knovel |b Knovel (All titles) | ||
| 650 | 0 | |a Nuclear activation analysis |x Health aspects. | |
| 650 | 0 | |a Nuclear activation analysis |x Safety measures. | |
| 650 | 0 | |a Electronic security systems |x Safety measures. | |
| 650 | 0 | |a Radiation |x Safety measures. | |
| 650 | 0 | |a Radiation dosimetry. | |
| 655 | 7 | |a elektronické knihy |7 fd186907 |2 czenas | |
| 655 | 9 | |a electronic books |2 eczenas | |
| 710 | 2 | |a National Council on Radiation Protection and Measurements. | |
| 776 | 0 | 8 | |i Print version: |t Pulsed fast neutron analysis system used in security surveillance. |d Bethesda, Md. : National Council on Radiation Protection and Measurements, ©2003 |z 0929600797 |w (OCoLC)53325111 |
| 830 | 0 | |a NCRP commentary ; |v no. 17. | |
| 856 | 4 | 0 | |u https://proxy.k.utb.cz/login?url=https://app.knovel.com/hotlink/toc/id:kpPFNASUS8/pulsed-fast-neutron?kpromoter=marc |y Full text |