UHMWPE biomaterials handbook ultra high molecular weight polyethylene in total joint replacement and medical devices

This book describes the science, development, properties and application of of ultra-high molecular weight polyethylene (UHMWPE) used in artificial joints. This material is currently used in 1.4 million patients around the world every year for use in the hip, knee, upper extremities, and spine. Sinc...

Full description

Saved in:
Bibliographic Details
Main Author: Kurtz, Steven M., 1968-
Format: eBook
Language: English
Published: London : Academic, 2009.
Edition: 2nd ed.
Subjects:
ISBN: 9780123747211
Physical Description: 1 online zdroj.

Cover

Table of contents

LEADER 04931cam a2200421 a 4500
001 82307
003 CZ ZlUTB
005 20200530182830.0
006 m o d
007 cr |n
008 090714s2009 enka sb 001 0 eng d
020 |a 9780123747211 
035 |a (OCoLC)424595784  |z (OCoLC)647777149  |z (OCoLC)655657051  |z (OCoLC)728658535 
040 |a OPELS  |b eng  |e pn  |c OPELS  |d OCLCQ  |d E7B  |d OCLCQ  |d OCLCF  |d ZCU  |d COO  |d OCLCQ 
100 1 |a Kurtz, Steven M.,  |d 1968- 
245 1 0 |a UHMWPE biomaterials handbook  |h [elektronický zdroj] :  |b ultra high molecular weight polyethylene in total joint replacement and medical devices /  |c by Steven M. Kurtz. 
250 |a 2nd ed. 
260 |a London :  |b Academic,  |c 2009. 
300 |a 1 online zdroj. 
336 |a text  |b txt  |2 rdacontent 
337 |a počítač  |b c  |2 rdamedia 
338 |a online zdroj  |b cr  |2 rdacarrier 
520 |a This book describes the science, development, properties and application of of ultra-high molecular weight polyethylene (UHMWPE) used in artificial joints. This material is currently used in 1.4 million patients around the world every year for use in the hip, knee, upper extremities, and spine. Since the publication of the 1st edition there have been major advances in the development and clinical adoption of highly crosslinked UHMWPE for hip and knee replacement. There has also been a major international effort to introduce Vitamin E stabilized UHMWPE for patients. The accumulated knowledge on these two classes of materials are a key feature of the 2nd edition, along with an additional 19 additional chapters providing coverage of the key engineering aspects (biomechanical and materials science) and clinical/biological performance of UHMWPE, providing a more complete reference for industrial and academic materials specialists, and for surgeons and clinicians who require an understanding of the biomaterials properties of UHMWPE to work successfully on patient applications. 
505 0 |a A Primer on UHMWPE -- From Ethylene Gas to UHMWPE Component: The Process of Producing Orthopedic Implants -- Packaging and Sterilization of UHMWPE -- The Origins of UHMWPE in Total Hip Arthroplasty -- Clinical Performance of UHMWPE in Hip Replacements -- Contemporary Total Hip Arthroplasty: Hard-on-Hard Bearings and Highly Crosslinked UHMWPE -- Origins and Adaptations of UHMWPE for Knee Replacements -- Clinical Performance of UHMWPE in Knee Replacements -- Clinical Performance of UHMWPE in Shoulder Replacements -- Clinical Performance of UHMWPE in Elbow Replacements -- Applications of UHMWPE in Total Ankle Replacements -- Clinical Performance of UHMWPE in the Spine -- Highly Crosslinked and Melted UHMWPE -- Highly Crosslinked and Annealed UHMWPE -- Highly Crosslinked UHMWPE Doped with Vitamin E -- Vitamin E-Blended UHMWPE Biomaterials -- Composite UHMWPE Biomaterials and Fibers -- UHMWPE/ Hyaluronan Microcomposite Biomaterials -- High Pressure Crystallized UHMWPEs -- Compendium of Highly Crosslinked UHMWPEs -- Mechanisms of Crosslinking, Oxidative Degradation and Stabilisation of UHMWPE -- In Vivo Oxidation of UHMWPE -- Pathophysiologic Reactions to UHMWPE Wear Particles -- Characterization of Physical, Chemical, and Mechanical Properties of UHMWPE -- Tribological Assessment of UHMWPE in the Hip -- Tribological Assessment of UHMWPE in the Knee -- Characterisation of UHMWPE Wear Particles -- Clinical Surveillance of UHMWPE Using Radiographic Methods -- ESR Insights into Macro Radicals in UHMWPE -- Fatigue and Fracture of UHMWPE -- Development and Application of the Notched Tensile Test to UHMWPE -- Development and Application of the Small Punch Test to UHMWPE -- Nano- and Micro-Indentation Testing of UHMWPE -- MicroCT Analysis of Wear and Damage in UHMWPE -- Computer Modeling and Simulation of UHMWPE. 
500 |a Previous edition: published as The UHMWPE handbook. 2004. 
504 |a Includes bibliographical references and index. 
590 |a Knovel Library  |b ACADEMIC - Pharmaceuticals, Cosmetics & Toiletries 
506 |a Plný text je dostupný pouze z IP adres počítačů Univerzity Tomáše Bati ve Zlíně nebo vzdáleným přístupem pro zaměstnance a studenty univerzity 
650 0 |a Artificial joints. 
650 0 |a Ultrahigh molecular weight polyethylene. 
650 0 |a Plastics in medicine. 
655 7 |a elektronické knihy  |7 fd186907  |2 czenas 
655 9 |a electronic books  |2 eczenas 
700 1 |a Kurtz, Steven M.,  |d 1968-  |t UHMWPE handbook. 
776 0 8 |i Print version:  |a Kurtz, Steven M., 1968-  |t UHMWPE biomaterials handbook.  |b 2nd ed.  |d London : Academic, 2009  |z 9780123747211  |z 012374721X  |w (OCoLC)299241974 